{ "@context": "https://schema.org", "@type": "Organization", "name": "Brainscape", "url": "https://www.brainscape.com/", "logo": "https://www.brainscape.com/pks/images/cms/public-views/shared/Brainscape-logo-c4e172b280b4616f7fda.svg", "sameAs": [ "https://www.facebook.com/Brainscape", "https://x.com/brainscape", "https://www.linkedin.com/company/brainscape", "https://www.instagram.com/brainscape/", "https://www.tiktok.com/@brainscapeu", "https://www.pinterest.com/brainscape/", "https://www.youtube.com/@BrainscapeNY" ], "contactPoint": { "@type": "ContactPoint", "telephone": "(929) 334-4005", "contactType": "customer service", "availableLanguage": ["English"] }, "founder": { "@type": "Person", "name": "Andrew Cohen" }, "description": "Brainscape’s spaced repetition system is proven to DOUBLE learning results! Find, make, and study flashcards online or in our mobile app. Serious learners only.", "address": { "@type": "PostalAddress", "streetAddress": "159 W 25th St, Ste 517", "addressLocality": "New York", "addressRegion": "NY", "postalCode": "10001", "addressCountry": "USA" } }

RQ-C-4832 (AOP Review - Shutdown w/ Failed Control Valve, Earthquake, Severe Weather, Loss of 250 VDC) Flashcards

(4 cards)

1
Q

When shutting down with a failed open control valve, why do we reduce power to a point that steam dumps are in service?

A
  • To minimize potential cooldown associated with the failed control valve
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Why is damage to the road west of the screen house considered criterion for shutting down in the Severe Weather AOP

A
  • Could result in debris in the forebay causing damage to CW and ESW (NRC commitment)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

During a loss of 250 VDC, what signal will be first to result in a reactor trip

A
  • RCP bus under frequency because DC control power is lost to a train of the relays which are de-energized to actuate
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What action can be taken during a loss of 250 VDC to avoid a single train SI when a train of 250 VDC is lost

A
  • Transfer the 2 affected CRIDS to CRP 3 prior to tripping the generator (not possible on U2 Train A)