Ropes 1 / LSR Flashcards
LSR :
- 9/16” DIAMETER
- 150 feet (shrinkage 8-10 feet)
- WORKING LOAD= 600 POUNDS
Intended use:
- Lower FF or another person from roof/upper floor to safety below
- Lower FF to REMOVE ANOTHER FF or PERSON from untenable position
- ALLOW FF to remove HIMSELF from tenable position (single slide)
Communications with the ________of the ladder company(s) is vital prior to any life saving rope rescue attempt. It is also critical that notification be given directly to_____?
INSIDE TEAM
INCIDENT COMMANDER or SECTOR SUPERVISOR
UNDER NO CIRCUMSTANCE should LSR EVOLUTION be attempted if:
- VIABLE substantial object is NOT AVAILABLE
- effectiveness of ANIT CHAFFING device would be compromised due to buildings construction (protruding facades, exposure, of the life saving rope to sharp surfaces)
- there are NOT ENOUGH members at the lowering point and at the adjoining windows or floors below to ensure a successful pick up and retrieval of the FF and victim
LSR evolution is LAST RESORT when all other avenues have been eliminated .
Any attempt to perform LSR EVOLUTION MUST BE in strict accordance with existing procedures
How many turns?
4 turns
- lowering of 1 person and /or use of the SINGLE SLIDE
- lowering of 2 people
-do NOT use LSR for drill
T or F…LSR should always be used with ANTI CHAFFING DEVICE.
TRUE
OOS for LSR:
Deputy.Tony.Hit.Home.Run.Far.Away D-doubt T-two people H-hockles (lose 40-50% of strength) H-heat over 300 degrees F lose strength/melt at 482 R-RUST/PERSISTENT F-frozen/ice strands/particles A-acid or acid fumes
After LSR is subjected to weight of ONE PERSON:
- carefully examined
- Journal Entry
- RP-100
- After SUPERVISING examination , NOTIFY SAFETY COMMAND via phone
LSR can lose 10-15% of its strength, when wet…but will regain this strength when it DRIES …
this loss of strength occurs when rope is submerged for 24 hours
-store in DRIEST COMPARTMENT in UPRIGHT POSITION
NEVER store ON Engine coves
Remove KINKS by ?
rotating rope counter to direction of kink
When do units INSPECT ROPE?
MONDAY 9X6
ENGINE: TUESDAY 9X6
- record on RP-100
- DO NOT conduct inspection on apparatus floor
Rope placed OOS:
- Notify DIVISION BY PHONE AND FAX and have LSR IMMEDIATELY REPLACED
- RT-2
- entries in COMPANY JOURNAL/OFFICE RECORD JOURNAL/RP-100
- new rope issued—NEW RP-100 (OLD RP-100 IS FILED)
- Complete OUT OF SERVICE LIFE SAFETY EQUIPMENT REPORT (SCF-2) and forward to CHIEF OF SAFETY
- RT-2/SCF-2 FAXED TO R&D
If LSR is placed OOS due to CONTAMINATION:
- note on RT-2 and Fax to R&D
- SOC will pick up from unit
LSR carrying case?
White with RED LETTERING