Rod Stops / Conditions Flashcards
1
Q
C1
A
IRM 20%
1/2 logic
Man block @ P10
Action: Stops Auto & Man Rod Withdrawal
2
Q
C2
A
PRM 103%
1/4 logic
No blocks
Action: Stops Auto & Manual Rod Withdrawal
3
Q
C3
A
OTΔT 1% < SP
2/4 logic
No blocks
Action: Rod Stop & Turb Runback
4
Q
C4
A
OPΔT 1% < SP
2/4 logic
No blocks
Action: Rod stop & Turb Runback
5
Q
C5
A
Turb Impulse Power < 15%
1/1 logic
No blocks
Action: Stops Auto Rod withdrawal
6
Q
C7
A
Turb Imp Power - Loss of load
1/1 logic
No blocks
Action: Arms Steam Dumps
7
Q
C9
A
Cond Vacuum < 6.5 HgA, 1 CCW
2/2 logic
No blocks
Action: Allows Steam Dumps < SP
8
Q
C11
A
Bank D @ 220 steps
No blocks
Action: Stops Auto Rod withdrawal
9
Q
C20
A
Turb Imp Power > 40%
2/2 logic
Manual PB
Action: Arms AMSAC