River Lynn Flashcards

1
Q

Logistical support will disperse controlled substances to individual ALS companies through the Rescue Chief as directed by the

A

Division chief of Rescue and the JFRD medical director

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Medication errors and reactions while the patient is under the care of Jfrd shall be reported immediately to receiving physician and the appropriate district/battalion chief the district/battalion chief shall then notify

A

The JFRD medical director and the division chief of Rescue within 24 hoursl

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Completed JFRD controlled substance daily checklist will remain with the notebook until collected by the district/battalion chiefs and forwarded to

A

The quality improvement officer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Any access to the safe will be witnessed by the appropriate individuals

A

Engineer will witness for the paramedic officer in charge or if officer is not a paramedic officer in charge will witness for the paramedic assigned to the MLS company

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Any discrepancies in the controlled substance daily checklist will be investigated by

A

The quality improvement officer and Rescue District/battalion chief with a discrepancy report provided to the division chief of Rescue and the Jfrd medical director

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Restocking of controlled substance Should occur when

A

Minimum LS engine inventory is reached
Minimum Rescue inventory is reached
Prior to expiration date
Prior to holiday or weekend when stock is close to minimum Rescue inventory ( does not specify engine )

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Who can change trauma alert status

A

The medical director of the EMS provider issuing the trauma alert
The physician at the receiving trauma center or hospital

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Infants and children less than blank you pedi immobilizer

A

60 pounds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The person that removes the chinstrap will support

A

The occipital and mandible of the patient

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Immobilizing a pregnant patient greater than blank may cause supine hypertension

A

20 weeks

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

How high should you elevate the right side of the back board of a pregnant patient

A

6 inches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The palm of the blank is equal to blank of body service area

A

Patient’s hand
1%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Which chemical burns cannot get wet

A

Lime
Carbolic acid
Sulfuric acid
Solid potassium
Sodium metals

Irrigate others with nacl 20mins

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

If blood is noted in the anterior chamber of the Eye ,position patient

A

In a semi Fowler’s position

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Hypertensive urgency is

A

Systolic greater than 220
Diastolic greater than 120

with or without symptoms

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Transport decompression sickness patients on

A

The left side recovery position

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Bites and stings
Remove the stinger If present and cleanse with

A

Peroxide

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Poison Control phone number

A

1-800-222-1222

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Rescue company officers are required to know

A

Detailed knowledge in emergency medical care and control of other emergency situations
The location of streets and the character of buildings within their respective response territory

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Suppression company officers are required to know

A

Knowledge in the prevention and extinguishment of fire in control of other emergency situations
Location of street and water supply sources as well as characters of buildings with in the respective response territory

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Engineers assigned to suppression shall know

A

The location of all streets water supply sources schools commercial buildings and other high life hazards in there first and second alarm territories

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Engineers assigned to the rescue division shall know

A

Streets and buildings in first and second do territory and shall know how to access our hospital emergency room is used by Jfrd

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Firefighters shall have a general knowledge of major streets and buildings in the city as well as

A

The locations of all streets and water supply sources and their first alarm territory they shall know the location of our schools commercial buildings and other highlife hazards in the first and second alarm territories

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

Request for bereavement leave will be in writing to

The document shall include the following

Extenuating circumstances for >90days after who can grant waiver ?

A

District/battalion chief

Name of deceased
Relationship
Data funeral
Location of the burial

Division chief

Also remember if addtl time require , the EMPLOYER may permit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Employees requesting military leave Shall provide blank and blank with a copy of the official set of orders
Supervisor and Jfrd employee services at headquarters
26
Documentation for paid parental leave must be submitted to
JFRD employee services immediately following the birth Immediately is explained as within two weeks
27
Employees shall notify employee services at least blank days prior to propose commencement of paid parental leave
30
28
Suppression Time swaps between company officers and firefighters sure only be permitted under extenuating circumstances with approval from the appropriate
Division chief
29
Following an inspection by state or federal agency
Notify district chief Notified division chief of training and advise of the results If a citations issued forward it to the district baytalion chief by hand if unable to deliver contact the district /battalion chief on that same day
30
District chief will deliver all monthly station inspection forms to
Assistant chief of operations by the 10th of each month
31
Prior to any type of gathering approval shall be obtained through the chain of command from
Station captain district chief Director Fire Chief
32
Participation and games or recreational activities of any kind will be permitted only between the hours
1000-2300 Other duties permitting
33
Which types of ppe shall be washed with Don dish soap and a soft bristle brush
Helmets and gloves
34
The protective hood shall be worn in conjunction with the
Helmet during fire suppression and other hazardous situation
35
Trumpet insignia shall be worn
With the mouthpiece pointing up in the barrel parallel to the front edge of the collar
36
Axe insignia shall be worn
With the blades pointing up and the handle parallel to the front edge of the color
37
Maltese crosses are worn on the blank sleeve of the dress jacket They shall be placed how high above the stripes Firefighter show place them where
Left sleeve of the dress jacket Half inch above the stripes 3 inches from the bottom of the jacket sleeve
38
Years of service patches If worn on a short sleeve shirt it shall be placed If worn with a long sleeve shirt it shall be
1 inch above the lower hem and centered under the patch 1 inch above the upper Cuff seam and centered under patch
39
Beanies
Only Jfrd or the company name and number are permitted
40
Fingernails shall not extend
More than a quarter of an inch beyond the end of the finger
41
When do Jfrd Check their fire extinguishers
Monthly
42
30 pound metal X extinguishers have a discharge range up to The extinguishing agent is
3 feet Sodium chloride
43
What is the range on a 2 1/2 gallon water can arc
The range is 15 feet
44
What is the range for 20 pound CO2
8 feet
45
30 pound PKp
All ladders hazmat seven and hazmat 21
46
30 pound lith x
Latter 10 hazmat seven hazmat 21
47
30 pounds sodium bicarbonate
Latter seven hazmat seven hazmat 21
48
30 pound metlx
Ladder one ladder four engine seven ladders seven engine 13 Engine 16 Engine 17 Engine 21 Tower ladder 21 engine 56
49
Atlantic beach phone number Neptune Beach phone number Baldwin phone number JEA
247-5874 270-2400 extension 4 Mayors office 266-5030 665-7907
50
Any private hydrant found in need of repair shall be reported to
The property owner and the district chief of inspections No district chiefs in inspections
51
When a infant is dropped off at a fire station FRCC will
Notify JSO and give the station location in the hospital to which the newborn will be transporting also notify the duty division chief and pio
52
When it comes to certification management each employee shall review their personal page for
Monthly
53
There are two official days they’re requiring the flag of the United States to be flown at half staff cording to the US flag code
May 15 peace officers memorial day half staff from sunrise to sunset Last Monday in May memorial day half staff until noon
54
There are two additional days that have an added through presidential proclamation’s for flag lowering
September 11 patriot day has staff from sunrise to sunset December 7 national Pearl Harbor remembrance day half staff from sunrise to sunset
55
Finished foam extinguishers and or prevent fire by the following methods
Separating cooling suppressing
56
Uniform to size bubbles provide long lasting foam blankets that are desirable
Post fire or unignited spill events.
57
Low expansion foam Medium expansion foam Hi expansion foam
20 to 1 ratio 20 to 1 to 200 to 1 ratio 200 to 1 to 1000 to 1 ratio
58
U L listed foam concentrates have a storage temperature of
35°F to 120°F
59
Aqueous film forming foam, film forming flouroprotein foam , and flouroprotein foams Are all compatible with
Carbon dioxide, Halon substitutes, and dry chemical agents and maybe simultaneously discharge with them
60
A triple F concentration environmental issues
Glycol ether’s butylcarbitol Perfluorooctylsulfonates. Pfos
61
High expansion foam are mixed at what %
1-2.5%
62
What 4 things affect the obtainable expansion ration of class A?
Water quality Aeration method concentrate ratio Concentrate formulation
63
The amount of liquid that drains from the bubble mask to wet or penetrate the class a fuel is affected by
Expansion ratio
64
When using Class a foam Fire attack and overhaul a standard fog
0.2 to 0.5% from concentrate
65
Class A foam exposure protection with standard fog nozzles
0.5 to 1% foam concentrate
66
Most operations with air aspirating foam nozzles
0.3 to 1% foam concentrate
67
Most operations with a compressed air foam system
0.2 to 0.5% foam concentrate
68
Application rate refers to the amount of finished foam that must be applied to a fire per minute per square foot of fire
In structural firefighting combat the application rate for class a foam is the same as the minimum flow rate for water
69
U.S. Navy’s formulation of foam
Milspec MIL-F 24385f
70
Some highly viscous foam concentrates may be difficult to proportion. Typically these viscous foams are
AR-FFFP pg 51 But on page 44 it says “ some foam concentrates are thick and viscous . These concentrates are typically AR-AFFF... “ keep an eye on that
71
1% AR Foam concentrates are available for use on hydrocarbon spell fires using
Type 3 application devices and procedures type three devices may include foam cannon or hand held nozzles
72
Alcohol resistive properties of flouroprotein foam last for about how many minutes
15
73
AFFF Stores at temperatures ranging from All other foam stores at
25 to 120°F 35 to 120
74
Film forming qualities of a triple F degrade at
140°F
75
Recently developed ARAFFF Are available in one by three formulations how do use them
Use at 1% for hydrocarbon spills 1 inch or less in depth and 3% for hydrocarbon spills deeper than 1 inch or polar solvents
76
Foam tenders or tankers capacity range from
1500 gallons to 8000 gallons
77
Foam concentrate tanks on fire and pumpers range from
20-200 gallons Arff May carry 600
78
In the erg If shipping paper isn’t available use guidance from which section
National assistance Located on inside back cover
79
Danger dangerous placard Nature of spilled leaking or burning material Unk Suspected hazmat but can’t see placard Use which guide ?
111
80
For orange placards a single asterisk means ? Double asterisk ?
Compatibility letter Division number
81
Top half of orange box in hazmat id is haz id numbers . European and some South Americans use it
Double for intensify (44) Number then zero for standard (30) Preface with x if reacts with water (x22)
82
Above ground markers for pipelines only mark which lines
Transmission lines
83
Initial isolation zone area surrounding incident with blank upwind and blank downwind concentrations
Dangerous upwind Life threatening downwind
84
Which bordered guide has evacuation -fire What does it mean
Orange bordered guide Evacuation hazard for fragmentation of large container
85
Material with protective action zone 11.0+ km 7+miles
Actual distance can be larger based on atmosphere Also snow , inversions , sunset may require using nighttime distances Also if temp exceeds 86f
86
What is table 2
Water reactive materials as well as toxins they produce
87
Table 3
Anybody can eat hot hairy snatch Anhydrous ammonia Chlorine Ethylene oxide Hydrogen chloride anhydrous and refridge liq Hydrogen fluoride Sulfur dioxide Large spills only >55gals Day and night Diff wind speeds
88
Spills involving 55 gals or 660 lbs or less
Small spills Greater are large spills
89
Certain chem warfare agents Small spill Large spill
Up to 4.4lbs for small Up to 55lbs for large BZ CX GA GB GD HD HL HN1 HN2 HN3 L VX
90
If an Id number can’t be found but name can , how do you find the number
Blue border pages have names in abc order
91
Explosives are not listed individually by either proper shipping name or ID number they do however appear under the general heading explosives on the first page of the ID number index and what color pages and alphabetically in the name of material index and what color pages
ID number yellow bordered pages Alphabetically and name blue border pages
92
How many individual guides are in the orange bordered pages
63
93
What are the three main sections of the orange order guides Which section should be consulted first
Potential hazards consulted first Public Safety Emergency response
94
A toxic inhalation hazard material is it gas or volatile liquid with a lethal concentration of
Lethal concentration 50 value of not more than 5000 ppm
95
Workplace hazardous waste containers will be picked up as needed and should be coordinated by contacting who
Hazardous materials coordinator who is assigned to the prevention division
96
If a course is canceled employee drops or quits the course or the course is changed he must notify the training academy when
On the next business day
97
After course completion employees must submit the following to Jfrd training academy no more than blank after the final grade is posted
30 days
98
How many weeks are eligible for FMLA for military caregiver leave
26 weeks in a single 12 month. Family member must have been in service with in the last five years
99
Maintain records of complaints filed at the JFRD eeo officer level for no less than two years in the event of state or federal charges of discrimination the department shall maintain all records relevant to the matter until win
Final disposition records are confidential and stored separated from personnel files
100
All city hydrants are equipped with a blank inlet and the flow will vary based on what
6 inch inlet Flow will vary based on the diameter of the water main and the Watermain pressure
101
City water supply main sizes
Residential 6 inches to 10 inches Commercial 8 inches to 36 inches
102
Private hydrants are transitioning to the color white as of 2016 what are the GPM‘s for the following colors Red Orange Green Blue
Read less than 500 orange 500 to 1000 Green 1000 to 1500 blue greater than 1500
103
The pressure setting on the transfer valve is known as what The volume setting on the transfer valve is known as what
Pressure is known as series Volume is known as parallel or capacity
104
The main difference in operation from a two stage pump is
Motor speed
105
How do the recirculating line and engine cooler line open ?
Quarter turn counter clockwise
106
The class 1 governor is on what units
Bought before 2008
107
The engineer must select pressure mode for the following fire ground operations
Pumping hand lines Pumping water pipes or ground monitors Supplying a sprinkler or standpipe system
108
The engineer must select RPM mode for the following fire ground operations
Drafting relay pumping Charging 5 inch hose PSi mode malfunction Hi rise pumping operations that exceed 300 psi
109
Other than rapid increase of _____ psi , there is no protection in rpm mode
30 psi
110
And volume mode the discharge pressure at Idle will be
30 to 40 PSI
111
If water supply runs low , the pump will increase rpm to maintain what psi
30 psi pdp , if it can’t , it will idle
112
Saber jet nozzle can be operated at 125 psi for both smooth bore and fog . When switching there is an increase of friction loss of ...
40-50 psi
113
Akron turbo jet nozzle booster line
100 psi 13,25,40,60 12345600
114
New high rise nozzle specs
Mini stream shaper Short stack tips ( 1-1/8” and 1/2” low flow) 1/2” tip is 30psi 40gpm 1 psi fl
115
High rise bag contents
2 1/2 inch in-line pressure gauge 2 1/2 inch gate valve 2 1/2 inch lightweight elbow Inch and 1/2 x 2 1/2“ increaser 1-1/2 fog nozzle 2 spanners Marking device 6- glow sticks 14-18” pipe wrench Flat and Philips screwdriver Allen wrenches 6-8” crescent
116
Attic nozzle
1000 sq ft 125 gpm @100 psi
117
Foam 37&371 carry how much foam
1800 gallons
118
Max distance between educator and nozzle
250’ for 75 psi nozzle 150’ for 100 psi 25psi Fl per 100’ of 1.75” , so you would have to pump higher which would result in no foam
119
Angus 240 specs and who carries it
Use with 2.5” hose Max inlet at eductor is 120 Carried by engine 1,7,11,21,30, 34,37,57
120
Akron 250 specs
Carried by 7,21,31 2.5 hose and nozzle , 250gpm 200 psi inlet 300’ max between eductor and nozzle
121
Specialized engine equipment generators have what plug ?
30 amp
122
Ground monitor psi plate
1-3/8 100psi 1-1/2. 100 1-3/4. 70 2”. 50 Max flow with fog nozzle 800 gpm
123
How to relay pump a high rise
First engine pumps at 100 psi , second engine receives 100 and increases as needed
124
Some older buildings may have psi limitations on standpipe of how much
200 psi
125
Max height for drafting If surface of water is ___ ft below steamer don’t expect to reach full rated capacity
25’ 10’
126
Drafting Static source must allow how mich clearance under strainer and how much above
1foot under and 18” over
127
Allow pdp to build to what before releasing primer
50 psi or steady psi , says different in different places
128
Tanker specs
2500/3000 dump tank 75 gals arafff 10 gals class A 10” dump valve (2-3 mins to dump 2500 gals) Approx 3 minutes to fill at 100psi
129
What to do when critical velocity is reached
Lower rpm Change nozzle flow (tip , gpm settings ) Increase hose size
130
Urgent repairs are occurring outside normal business hours that require overtime must be authorized by
FRCC shift supervisor
131
If back up FRCC is activated field personnel will be notified through
FSAS and all stations broadcast
132
Units requesting to leave first to territory While remaining in service will
Secure permission from the appropriate Chief Coordinate through FRCC
133
What is an alert 2
Alternating high low tone for duration of one second Use for dispatch of apparatus on available status
134
During multiunit response is the downgrading of an initial assignment may occur if
On scene unit provides an initial report next on a fire classification next line in the appropriate Chief advises fire COM to commence Roll call
135
When a signal 34 is called they will dispatch an emergency assistance request assignment What does that consist of
Maximum investigative assignment as well as , Rescue unit, Rescue Chief,and Appropriate law-enforcement agency
136
Which stations will be covered at all times
40. 48 and 55
137
Which companies will not be used as transfer companies
Suppression apparatus with the hazmat team and special operations team as well as rescue 16
138
Who gets dispatched for secondary rit on all W3 involving large commercial structures Also second alarms
Ladder four and heavy rescue four and fire four
139
Usar team is combined of
All members of the specialize response teams on or off duty 7,21,4,13 Will be activated by administrative requests
140
Tact support can be reach by
A8 or 6931445 from 700-1700
141
Favorable conditions
Light traffic dry pavement good visibility good roads
142
The use of ics is mandatory when
5 or more units
143
Subdividing should occur in either of the following conditions
The incident is developing such that it will eventually involve a number of resources or functions beyond an effective span of control Companies are becoming involved in complex operations Incident requires close control of companies
144
What is the standard for all incidents requiring a full assignment or greater
Level one staging
145
Level to staging will require the designation of a blank and the blank both designated by command
Staging officer informal staging area The staging officer shall coordinate with rehab for Available resources on scene
146
Any company officer who suspects or is notified that there is a missing or trap firefighter show Immediately notify who
Incident commander or division/group leader
147
Who will begin a rollcall by requesting an alert three
Command
148
For engineers working in the hot zone what ppe is optional
Gloves Scba Face piece
149
Structure fires within complexes that utilize private hydrant you require the third arriving engine to stage where
On a municipal hydrant outside the complex
150
The fire ground is considered to be in Rescue mode until when
Until an all clear is given
151
Minimum assigned for w4
1 engine 1 ladder 1 rescue Rehab 5 Air 5
152
W4 automatic in following cases
Units exceed 1 bottle prior to 77 > 40 mins strenuous activity prior to 77 2nd Alarms or greater
153
First alarm for high rise
5 engines 4 suppression chiefs 3 ladders 2 squads 2 rescues 1 rescue chief Special ops team
154
Attack one upon arrival to fire floor report what
Conditions actions needs
155
In high rise , first squad should
Announce a stairwell and ascen to top of building , look on all sides for victims or fire , do a primary on top floor then descend opposite stairwell
156
First suppression chief in high rise immediate actions
Ensure 2&;3 alarm and level 1 mci also level 2 staging area Only two engines and one ladder come per alarm
157
Who must ensure a surplus a drag blanket and stair chairs
Rescue chief
158
StairwY support group should be considered if
elevator use is not available and FORWARD STAGING above 7th floor , created by lobby control
159
Phase 1 elevator mode may be activated by
Fire alarm by smoke Fire alarm by heat sensors Manually with key
160
Which buildings elevator are required to be keyed the same by the state of Florida
7 stories or more
161
Oldest standard for standpipe psi guarantees
65 psi minimum
162
A prv can be used more Efficiently by
Placing 2.5” gate or ball valve on it
163
If the structure is deemed too large for effective RIT coverage with one team
A second RIT ASSIGNMENT should be called upon to set up opposite the first .
164
If not already on scene when a mayday is Called ____ should be dispatched as soon as a mayday is called
Technical rescue team
165
If available who should be stationed at the entry point of RIT team
Ff not assigned to RIT
166
Guidelines abnormal fire behavior w/ multi structures threatened and low resources Structure deemed hopeless when : Structural protection :
25% or more of roof involved Low water supply Personnel at risk 15 min commit 1 unit per structure in isolated area 1 per 2 structures in subdivision Limit hose to 200’
167
Hurricane season
June1- nov30
168
Hurricane alert Watch Warning
84 hours prior to landfall 36-60 24-36
169
Saffir-Simpson hurricane wind scale 1 2 3 major 4. Major 5. Major
74-95mph some damage 96-110. Extensive 111 -129. Devastating 130-156. Catastrophic 157 or higher Catastrophic Remember first number and the rest is explained
170
During hurricane May be divisions N S E W Beaches All divisions must coordinate closely with
Operations section at EOC
171
On May 1 the station captain will report any deficiencies to ____ Who will then submit the hurricane season checklist to_____
Battalion chief (not district ) Division chief of services ( who is that ?)
172
Hurricane alert what needs to be done
Secure all windows above the first floor locate and fill all water containers Top off LP tanks Contact logistical support for delivery of prepackaged rescue supplies
173
Hurricane watch what needs to be done
Secure all first floor windows Secure all loose items at and around station Have all reserve apparatus fueled and fully loaded Designated stations should make preparations to evacuate
174
Hurricane warning what should be done
Notify personnel to anticipate staying additional shifts Top off apparatus fuel tanks
175
Should the conditions warrant an unscheduled evacuation of the station the officer in charge will notify
District chief and the fire group supervisor
176
No authorization shall be granted in advance for anyone to stay in a Jfrd facility without the express permission of
Appropriate division chief
177
Hurricane In the event there is a lot of communications the waiting list will be forwarded to
Emergency services branch or to each division if established
178
Dividing of zones at a hazmat incident is the job of
Hazmat team
179
The success of Decon is based on
Standardization
180
Methods of decontamination
Dilution Absorption Degradation
181
All Jfrd personnel who are decon should stay in rehab for
30 mins
182
Any residual contaminants found by other shifts shall warrant a notification of
District chief
183
Train electrical hazards
440 v dc generators
184
Lz criteria
100•100 Slope less than 5degrees 30’ clearance for approach path Ems personnel 100’ from touchdown area bystanders 200’
185
Confined space Wait for arrival of DISTRICT CHIEF. If any following
Victim is obviously deceased Is out of line of sight Entry can’t be made with scba worn properly
186
Entry rescue team
RIT. For confined space 2 for 1 personnel on entry team
187
All teams will be equipped with an atmospheric monitor while in
Confined space (not hot zone )
188
Confined space Increasing the o2 content above __ could result in a very dangerous atmosphere
21%
189
Nylon static kernmantle becomes sticky at __ melts between ____ and ____
445 480 500degrees F
190
The fm200 extinguishing system is used in three areas of skyway building
Control room Computer room Signal room
191
Car capacity of skyway
56 total or 28 per car (a&b car)
192
Respiratory protection Chiefs and CO will ensure that personnel under their supervision are
Able to don and doff scba Trained quarterly until proficient enough to don within 2 mins
193
PASS. Stands for
Personal alarm safety system
194
The air quality for cascade systems for scba will be tested at least every
3 MONTHS
195
Requests for pick up on bio hazard bins will be submitted when they are full or
After 1 month since last pickup , whichever comes first
196
Any employee knowing of or suspecting another employee of having an infectious disease shall notify ...
CO , who will notify HSO , who will notify director fire chief
197
Who fills out the infectious control paperwork Jfrd exposure report Jfrd source patient blood/body fluid exposure tracking form
HSO HSO or RESCUE district or battalion chief Fax number for HSO 630-0609
198
Bc hostage incidents can be extended duration , it is recommended that deployments be limited to
2 hour roatations , with relief crews notified 30 minutes prior to allow for travel time
199
In all cases , weapons must be safeguarded by LEO , the company officer will document his
name , RANK , and Id number
200
In cases where resistance is met to put out a open burning fire , Jfrd personnel will
Ask frcc to request JSO , notify reg and enviro services dept air and water quality div, unless after working hours or weekends/ holiday , then they will request district chief Also smoke can’t be greater than 40% opacity
201
Which copies got to chief of prevention when a citation is given
White and yellow Pink copy goes to person cited
202
If needed to contact on call stat fire Marshall his number is
904-359-5874 through state of Florida Jax regional com center But it also says all request for firemarshall shall go through frcc
203
All fire reports must start with the
Statement of responsibility Whether accidental unknown or Carelessness design
204
What is the purpose of 431 marine operation
To provide Jfrd personnel with guidelines for responding to waterway incidents and deployment for hurricane ops
205
Which channels must be monitored while underway in marine units
Marine channel 16 and A2 A10 is marine channel for JFRD , when using it someone on boat also needs to be on the proper talk group to relay info
206
While underway anyone outside cabin shall wear
Safety harness as well as pfd
207
Who terminates an alert Alert 1: local standby Alert 2: full emergency Alert 3: aircraft accident
Alert 1: atct Alert 2: ic will notify atct and jaa aocc when terminated Alert 3: jaa aocc or Cecil ops will notify atct when terminated
208
Moving aircraft components , wreckage , mail , or cargo should be limited to the extent necessary to accomplish any of the tasks below
Removing injured or trapped victims Protecting the public and firefighters from injury Protecting the aircraft from further damage
209
Cargo and passenger aircrafts may be carrying dangerous goods , if by the following methods
All methods outlined in 411 hazmat The cargo manifest Labeled “cargo aircraft only “
210
Evacuation slides explosively deploy from most non over wing emergency exits approx how far
2 feet past either side of door opening
211
Airplane exploding stored energy devices
Airbags Fusible plugs Hydraulic accumulators O2 cylinders Aircraft tires Ballistic parachute systems (typical found on small general aviation )
212
Hydraulic fluid amount on aircraft
Approaching 200 gallons
213
Certain military aircraft (f16) use what in EPU
Hydrazine
214
Approach military aircraft at 45 degree angle from nose or tail due to
Armament Fusible plugs Navigational aids
215
Interior attack airplanes Who will decide if foam lines are needed prior to entry
Attack company oic Also in 432.14 it states arff apparatus are primary units for fire suppression agent application , will deploy attack lines as directed by Jfrd ARFF OIC CONFLICTING
216
Maximum inlet psi for filling all Arff apparatus
80 psi
217
St 16 uses C3 to talk to who
Unit to unit FANG JAA OPS JAA PD
218
St 56 uses A12 for unit to unit and what to communicate to ATCT
Cecil ground channel
219
Per 434 Inner company communications should be face to face but can move moved to another channel like b2 after notifying
Incident commander
220
Members shall undergo rehab for 20mins when
Post complete use of 45 min scba 40 mins of work with no scba
221
Conditions to be released from rehab
20 mins Systolic >90 <160 Diastolic >60 <110 Pr >50 <100 Temp <100 CO <10% Resp >10 <20
222
Active assailant incidents are usually over before
Leo arrives on scene 10-15 mins
223
Contact team
Rapidly assembled team of LEO responsible for locating and stopping an active assailant
224
Rescue team (445)
TeaM of LEO who move victims to ccp
225
445 Jfrd apparatus will remain in staging until directed by ..
Unified command
226
Ballistic vests and helmets are only to be worn when directed by
District or battalion chief
227
Chiefs jobs at shipboard fire
Fire chief 1: advantageous location assume command Fire chief 2: ISO Fire chief 3: operations section chief (on deck) Other fire chiefs : go to ic for task Rescue chief 1: rehab and EMS section chief All other rescue chiefs : go to IC for tasks
228
449 considered assigning a ____ to Track ff entry times and location
Air supply officer
229
449 The IC should contact who to develop a plan for the transport of equipment from apparatus to pier , pier to deck of vessel
Fire 4 Trt has vehicles that can move stuff and hoist equipment . Also port reps for use of possible cranes
230
449 Max psi for ISC is
150 psi
231
449 companies will bring
One spare bottle per person plus Engine - 150’ 1-3/4” hose and high rise bag Tracer line , tic,ISC adaptor , bolt cutters Ladder - 2 bags of hoisting rope , 5:1, tracer line , irons ,TIC, hydra ram ,bolt cutters Squad- RIT EQUIPMENT for needs presented Rescue - jumpbag,o2,monitor,stretcher
232
450 The wet soap Devon process has been shown to remove up to ___ of contaminants
85%
233
456 Forcible entry is also appropriate when dispatch info or on scene conditions indicate ...
The activation of fire extinguishing systems such as : Sprinkler water flow Halon CO2 Dry chem Hood system
234
456 If Jfrd replaces a head then that info must be relayed to
Alarm monitoring service Building rep if on scene Frcc Documented in Jfrd run report District chief of prevention
235
461 Who does a 360 at the vehicle extrication
The Officer in charge
236
461 once the engineer of the first engine has the hose line set up and is in full ppe whindo they report to
The officer in charge Pretty much everyone else on scene goes to command for directions
237
The effects of fire conditions on a building are extremely significant . Factors that influence fire behavior include
Building construction Occupancy classification fire or fuel load fire resistance
238
Floor construction in type 1 must be rated for Roof deck and construction supporting roof
2-3 hours 1-2 hours
239
In type 2 construction In addition to steel and concrete block ____ and ____ can be used in limited structural role
Glass and aluminum
240
Type 2-A construction requires that structural components have
1 hr fire rating
241
Type 3 construction typically uses 2x10” joists for
Floor construction
242
Concealed spaces in type __ must contain fire stops
3
243
Concealed spaces aren’t permitted in type __ construction
4
244
Type 4 construction requires min dimensions of ___ for floor construction
6x10”
245
Many type 5 construction require 1 hr of fire resist for
Structural components Achieved through drywall and plaster
246
The total quantity of combustible materials in a compartment
Fuel load
247
The max amount of heat that can be released if all fuel is consumed
Fire load
248
The fire load is the product of the weight of combustibles times the heat of combustion expressed in
Lbs per sq ft
249
BC The test results will be classified as either ______ or ______ In addition the fire resistance ratings are developed for _____ and ______
Load bearing or non load bearing Restrained and unrestrained
250
BC One failure criteria is the temp increase on in exposed side of wall , floor , and roof of _____ above ambient temp
250 degrees
251
Despite’s limitations of lab controlled testing , the ______ is the only standardized test method universally accepted
E-119 AKA NFPA 251
252
BC For example structural steel designated ____ or ___ is the most prevalent steel used in compiling the test data
A7 A36
253
Unique stresses are caused by external load alignments including
Axial load Eccentric load Torsional load
254
In buildings designed to withstand wind pressure , what is the primary type considered
Direct pressure
255
Seismic load types Directional movement includes
Lateral - horizontal , most significant force generated by quake Torsional - twisted Resonant
256
The center horizontal line of the web is known as the ____ bc the tension and compression is zero , but is the max point of shear stress
Neutral axis
257
Typical truss shapes spans distances of ___ to ___ but modern constructions May exceed ____
22-70 ft 100 ft
258
______ are 3D truss stRuctures
Space frames
259
Steel stud wall construction has studs placed ___ to ___ apart
12-16”
260
Post and beam construction may use posts size ___ by ___ when supporting roofs only
6 by 8”
261
Rigid frame facts
Often single story with gabled roof Steel , laminate wood , reinforced concrete Peak of roof usually hinged The joints will be last portion to fail under fire
262
The intersection between a slab and column is usually reinforced by
Drop panel Capital
263
Membrane structures _____ usually address structures with life of more than 180 days _____ address’s those with life less than 180
Building codes Fire codes
264
What are rigid 3D structures having thin components
Shell stRuctures
265
Under fire conditions _____ and _____ exerted on a structural system are subject to change in magnitude and direction
Loads and stresses
266
Building that are ___ or more stories in height may be required to include one stairway that extends to the roofs for access
4
267
This type of stair is most often located away from the buildings usual functional spaces
Folding ladder
268
Building codes have traditionally required a minimum of one smokeproof stair enclosure for stairs serving buildings ______ or higher
5 stories More recently they also require for stairs serving more than 30 ft below ;basements
269
Even though counterweights reduce the amount of energy needed to raise the elevator , operating heights may require as much as ___ volt power supply
500v Ac or dc
270
Ac vs dc drum brakes on traction motor elevators
Ac slows and stops on floor Dc doesn’t help slow or stop , just holds at floor while stopped
271
Elevator hosistway enclosures usually are required to be fire rated assembly with a __ or ___ hour rating depending on height of building
1 or 2 hr
272
Elevators and stairwells are built early and often use ____ walls
Shear
273
To prevent mushrooming codes require ___ at top of hoistway , also require fire rated ____ or equivalent .
Venting Vestibules
274
Duct detectors are typically provided for fans with capacities exceeding ____ cfm
2000
275
Due to environmental concerns , some halogenated refrigerates have been prohibited some gases used in their place are dangerous to ff , they are
Butane and propane
276
Ductless interstitial spaces are used as a
Return air plenum
277
NFPA 90A(c) requires that the enclosure be 1 hr for buildings less than ___ stories in height and 2 hour for taller
4
278
Some large ______systems have cooling towers staged on a buildings roof Hvac
Hydronic
279
The following systems can signal hvac controls to transfer to smoke control
Smoke detectors Heat detectors Sprinkler water flow switches
280
Smoke vent hatchways often open a minimum of __ft in either direction
4
281
Draft curtain boards Depth - Spacing -
Depth - not less than 20% ceiling height Spacing - not farther than 8 times ceiling height
282
Roof vents in a sprinklers building may be of max value in removing productions of combustion during
Final stages and overhaul .
283
The electric utility company supplies many buildings with ____\____ bolt series , which carry same amount of energy in smaller wire and conduit when compared to traditional ___\___ volt services
480/277 120/240
284
When transformers are inside , codes require that the transformer room or vault be enclosed in _ hour rated construction if no sprinklers and _ hour if sprinklered
3 1
285
The amount of minimum fuel for generator for expected duration may vary from _____ to ____ hours
2-8 hrs Hospitals etc may require >48hrs
286
Day tanks typically limited to how many gallons
60
287
Roof slopes Low slope - Med to high slope -
3/12 4/12-12/12
288
Lamella arch Lamellas are typically sized ?
2x8”-3x16” and 8-14 feet long Has compression and tension rings , ones fails all fails
289
What is a dormer
Frequently in pitched roof building , like a gabled attic window
290
Wood rafters vary in size from __x__ to __x___ they can be spaced from 12-24”
2x4 to 2x14 The ridge beam typically one size larger than rafter
291
Lightweight wood trusses are usually __•__ or ___•___ and individual trusses are spaced __ to __ ft apart
2•4 or 2•6 2-4’ apart
292
Corrugated steel used in roof decking ranges from ___ gauge to ____ gauge The overall depth varies from _____ to _____
29-12 gauge 3/4-2”
293
When cast in place concrete is used as a roof deck , wood nailing strips must be placed every ____
3’
294
Built up membranes using felt have sections that are _____ side and commonly ___ layers deep . They usually last for __ years
3 ft 4 20 years
295
Single ply membrane roof come in sheets ___ or ___ wide and up to ___ ft long
10 or 20’ wide 200’ long Typically .03-.10 inches thick
296
Materials may be shaped to to resemble other roof coverings such as wood shingles , these include :
Porcelainized aluminum Mineral based materials Composite materials
297
Slate tiles can be as thin as ___ or thick as ____ Life expectancy is ___ Weight ___
1/16th of an inch to 1.5” 150 years ! 8-36lbs/sqft
298
For NFPA 256/astm E-108 Test may be repeated ___ to ___ times . Six separate tests are : They are classified as A,B, or C
2-15 times Intermittent flame exposure Burning brand Flying brand Rain test Weathering Spread of flame A- effective against severe fire B-moderate C-light
299
Green roof Depending on depth of soil the dead load can vary from ____ to ____
20 lbs/sqft to 150lbs/sqft
300
Model building codes define high rise as
More than 75’
301
Typically model building codes require the structural frame of a high rise to be And how many hrs for floor
2-3 hr frr depending on # of floors 2
302
Building codes have routinely required that high rise buildings be equipped with sprinklers as well as standpipes since
Mid-1970s
303
Model building codes don’t require special mechanical smoke removal provisions from the floor of origin bc the following should be adequate : - - -
- shaft construction -sealing of floor penetrations -automatic sprinklers Interpreting this to mean ( doesn’t require “special” smoke removal , like a negative vacuum ) just lets hvac and pressure sandwich do the work ... kinda confusing so remember
304
Codes require smokeproof stairs in all stairs serving floors ___ ft or higher
75’
305
Only consider using the elevator if fire is above __ floor Not Jfrd , comes from bc book
5th
306
Codes contain mandatory provisions for recall in all passenger elevators with vertical travel of greater than ____ in the event of fire
25’
307
Phase 1 can be triggered by : Different than Jfrd ..... from BC BOOK .
Smoke detectors Sprinkler flow alarms Manual key Conflicting and doesn’t include heat sensors , the Jfrd manual doesn’t include sprinklers
308
Limited or controlled access buildings must have emergency access openings on ___ or more sides in upper floors
2 Operable from interior or exterior
309
Probably the greatest single challenge in controlling fires in underground buildings comes from
Difficulty in venting heat and smoke
310
Air inflated vs air supported
Air inflated is like a bouncy house Air supported is a bubble with air psi inside
311
Malls maybe built of _____ but many are _____ or _____ Construction types
Fire resistive ( type 1) Noncombustible (2) Wood (5)
312
Current codes have eliminated smoke control for __ story Mall but may be required for __ or more stories
1 3
313
Building codes may require that atriums be enclose with ____ hr fire rated construction or a combo of ___ and ____
1 hr Glass and sprinklers May eliminate 1 hr enclosure up to 3 stories if certain conditions met Also may waive sprinklers if ceiling >55’
314
max psi during an explosion may exceed :
10 times atmospheric psi
315
Ideally , explosion vents panels shouldn’t weigh more than
3 lbs/sqft
316
Area of refuge Smoke barrier must be rated a minimum of : Also must be provided with some type of :
1 hour fire rated enclosure Two way communication system connected to a constantly attended location
317
Warehouse storage rack may be wider than ___ or with aisles narrower than ____
12’ 3.5’
318
Storage racks height can vary from
Total height of 12’-excess of 100’
319
When writing equipment guidelines the seven things to consider
Selection Use Cleaning and decon Storage Inspection Repairs Criteria for retirement
320
A quick look at ff injury and death stats shows ___ equipment can make a diff
What
321
Identifying hazards is the primary function of
The ISO
322
Five step risk management
5 “hazards” Identification Evaluation Prioritization Control Monitor
323
Hazard control hierarchy
Design Guard Warn More complex hierarchy Eliminate , substitute , isolate , adopt engineered controls , apply controls , and ppe
324
Fire service mitigation hierarchy
Elimination Reduction Adaptation Transfer Avoidance ERATA
325
Based on studies by NIST and UL , modern fire is - - -
Hotter Develops tremendous energy (heat release rate ) Contains smoke that is extraordinarily explosive
326
Some gas of significant quantity that affect fire behavior are :
CO hydrogen cyanide Benzene Acrolein Hydrogen sulfide
327
Smoke is ignitable at ____ and has a colllectible flammable range of ___ to ____
450 1-74%
328
Two triggers may cause accumulated smoke to ignite
The right temp and right mixture
329
6 phases of a ventilation controlled fire
Ignition Initial growth Ventilation limited Explosive growth Fully developed Decay
330
Laminar smoke leaving a building doesn’t mean it is safe , it only means :
The box is still absorbing heat
331
Black fire can reach temps over
1000f
332
What four things can change appearance of smoke
Weather Thermal balance Container size Firefighting efforts
333
In thermal Balance , the separation of hot smoke and cool air is known as
Boundary layer or neutral plane
334
Bring ________ _______ requires recognizing predictable dangers and taking step to reduce risk taking by fellow responders
Intellectually aggressive
335
Perhaps the most important decision that the iso has to make at an incident
Determining the appropriateness of risk taking ( acceptable or unacceptable within defined criteria
336
Dr Gasaway three levels of SA
Capturing current cues and clues Comprehending the situation Predicting the future
337
Iso read risk model 3 step process
Collect info -SA cues and clues Analyze Judge risk
338
Developed by USCG as a risk taking model
Severity 1-5 Probability 1-5 Exposure 1-4 SPE Multiply rating together 1-50 go ,50-80 reassess risk ,81-100 no go
339
Integrity of electrical systems is based on
Proper ground Insulated Circuit protected
340
Large transformer fires can be extinguished but it takes copious amounts of water to bring the temp below
400f ignition temp of oil
341
Hazards associated with wind turbine are usually proportional to
The size or scale of the turbine .
342
Individual blades of turbine can extend
60-130’ creating danger zone of >300’ Tips if 60’ blade traveling > 70 mph
343
Pooled water , battery acid and battery rack can become ___ energized bc there is typically no ground fault protection with ___ power
DC Likewise these batteries are typically in slow charging system which produces hydrogen gas
344
Roof dead load of 3-5 lbs/sqft , a standard 3x4’ panel weighs 40 lbs
PV solar system
345
Solar thermal systems have a dead load of
5-8 lbs /sqft
346
Lightweight high rack storage systems can be classified as stored ______ _____ in the form of dead or live loads and _______
Potential energy Gravity
347
On electric cars or hybrid Bright orange cable indicates high voltage up to _______ is used in drive train Bright blue cable indicate
700v and 125amps Med voltage but more than 12/24v
348
Vehicles powered by cng , lng, or lpg are required to have a decal where
Right rear of car and adjacent to filling area Cng/lng - blue diamond LPG - black diamond
349
Victim trapped in car with undeployed airbag is in danger consider this an __________ rescue environment
Immediate
350
Large hail ____ or larger can indicate you are near where a tornado is most likely
1/4”
351
Considered the first action or priority when dealing with hazardous energy
Hazard awareness
352
3 stressors that influence overexertion are related to
The environment Human physiology Quality rehab
353
Although medical varies , most agrees that core temp above ___ and below ____ will start to affect physical performance
101 96
354
Studies show that ff engaged in ops wearing full ppe will have temps averaging over ____ after _____ minutes of activity
101.5 20 mins (or one bottle )
355
Passive cooling includes the use of
Shade , air movement and rest to bring down core temps
356
The prevention of thermal stress can be Accomplished through
Accommodation Rotation Hydration
357
______ and _____ lead the list of hundreds of contaminants that interfere with o2 intake
CO Hydrogen cyanide
358
Ideal balance for carbs protein and fat
40/30/30
359
NFPA 1584 standard on the rehab process for members during emergency operations and training
Addresses responsibilities of fd to do rehab Rehab sops Job of ic , co , rehab manager , and individuals
360
NFPA 1561 ems management system and command safety Aka five components of rehab Priority order
Shall ensure rehab started : Rest, hydration , bls , energy nutrition , accomodation for weather RHBEA
361
NFPA 1521
Standard for iso
362
Factors that may initiate rehab
Incident time Complexity Intensity Weather issues
363
Most important v/s to stabilize in rehab
Core temp
364
10/20 rule for rehab
10 min break after first bottle , 20 min break for the rest of breaks Unless 60 min bottle , then 20/20
365
NFPA 472 4 step response model for actions at hazmat
APIE analyze the incident Plan the initial response Implement the response Evaluate progress
366
Hazmat incidents three primary mechanisms of injury
Energy release Corrosivity Toxicity
367
Bulk packaging refers to packaging other than that on a vessel or barge . No intermediate form of containment . Criteria:
Liquid 119gals Solid. 882 lbs Gas 1001 lbs
368
A cryogen is a gas that turns to liquid at or below
-130 at 14.7 psi
369
What is a reactive material that when in contact with moisture gives off flammable gas
Calcium carbide
370
RAM shipped in 5 basic types
Excepted - no risk Industrial - lab samples and smoke detectors Type A - withstand series of test Type B- withstand severe accidents Type C- very rare transported by aircraft
371
Placards must be on
Bulk packages Rail tank cars Cargo tank vehicles Portable tanks ULD with >640 cubic ft of hazmat Certain non bulk
372
A placard is no required for shipments of
Infectious substances , other reg materials for domestic use only , materials of trade , limited quantities , small quantity , RAM(white label 1, yellow label 2), combustible liq nonbulk
373
Elevated temp material for transport :
-Liquid phase at or above 212 -Liquid phase with flash point 100 that is intentionally heated and transported at or above it flashpoint -solid phase at a temp at or above 464
374
Canadian placard differences
Most don’t have signal words English and French Requires a unique placard for anhydrous ammonia and inhalation hazards Radiation placard May have 4 digit UN Same as Mexico except mex doesn’t recognize inhalation and may be Spanish
375
NFPA 704 uses a rating system 0-4 assigned to 3 categories :
Health flammability instability Special hazards are located in the 6oclock /no specified color but white is common Only w with line through and OX allowed in white but old ones have other stuff ie trefoil radiation
376
HMIS hazard material info system is similar to
NFPA 704
377
General caution symbols USA- Mexico- Canada-
Rectangular (like old glory ) Triangle (tequila) Circle (Canada )
378
GHS includes two signal words EPA includes a third word
Warning - less severe Danger - more severe Caution - in addition to those
379
ANSI Z535.1 sets forth safety color code recommended for use in is and Canada : Red Orange Yellow Green Blue
Red - danger or stop , flammable liquids,emergency stop bars , stop buttons and fire protection Orange - warning energized equipment hazard machine can crush or cut Yellow - caution may trip , corrosive or unstable Green- safety equip Blue- safety info signage
380
Basic description provided in shipping papers will follow sequence I S H P
Identification Shipping name Hazard class or division Packing group Ship ishp
381
Safety data sheets have 16 sections . Which ones are first aid and firefighting
4- first aid 5 -firefighting
382
As with the senses , monitoring and detection devices require contact in order to measure therefore it out side scope of ____ level personnel
Awareness
383
Access to the LOCKED storage safe will be limited to
Medic OIC or if oic not medic , medic assigned to als company
384
The proper procedure is for all report authors to ensure their name is listed
In the first top position on the sign in roster
385
Proper format for ems report
CC HPI PE Tx Note
386
Ensure signature on back of form is in appropriate area -
AMA refusal or non emergency non transport
387
Med director and QI. Officer will communicate on a ______ basis
Weekly
388
QI office will forward any signature queries to the
Author , district /battalion chief and Jfrd ems billing manager So they don’t bill it till straightened out
389
State of Florida requirement for reporting abuse :
Oic calls 180096abuse obtain name and id number Notify rescue district battalion chief Notify div chief of rescue via email within 24 hrs with name and id of white you talked to
390
Durable POA must be on Notarized POA document signed by DNRO MUST BE SIGNED BY
Pt and two witnesses Physician and Pt , if pt incapacitated , can be signed by health care surrogate or proxy , court appointed guardian , durable POA
391
Death scene procedure If cop doesn’t let you in , Tethys are assuming all responsibility , you must obtain
Name and Id number
392
Transport required for Need to remember only
Systolic <90->180 Diastolic >110 15 yo or less who are symptomatic 65 or older
393
Which standalone ER are allowed to have pets transport
Baptist clay , north , town center
394
Alternative transport options for a service animal are :
Family Friends Neighbors Animal control District/battalion chief LEO
395
Mini horses generally range from ___ to ____ “ high measured to the shoulders and generally weigh ____ to ___ lbs
24-34 60-100
396
Adult trauma single criteria
Airway - anything more than o2 Circulation- no radial w/pr >120 or systolic <90 Best motor - 4 or less on Gcs motor , paralysis , or suspect spinal injury or loss of sensation Cutaneous - 2nd or 3rd burns 15% or more ,ampu proximal wrist/ankle, penetrating head neck torso 2 or more long bone
397
Adult double criteria trauma alert
Airway - rr. 30 or more Cir- 120 or greater Bmr- 5 gcs motor Cutaneous - degloving or avulsion >5” Long bone - single long bone from Mac or fall 10’ or higher Age-55+ Moi- ejected or steering wheel deform
398
Peds trauma alert single Anatomical and physical of 15 or less
Airway - intubated , position , suctioning , adjuncts Circ- faint or absent carotid or femoral , or systolic < 50 Consciousness - ams , drowsy, lethargy ,can’t follow commands , unresp to voice , totally unresponsive , coma,paralysis,suspicions spinal, loss of sensation . Fracture - open long bone , multi fx or disloc Cutaneous - major soft tissue ,2/3 burn 10 or more , amp prox wrist ankle, penetrating head neck torso
399
Peds double criteria
Consciousness - amnesia or loc Circ- carotid/femoral palp but the radial or pedal absent , systolic <90 Fx- single closed long bone Size - 11kg or less , body length equal to this weight on peds tape(33” or less)
400
Assessment of pediatric pt requires OPA
Observation auscultation palpating
401
If pt ____ yo or less , and has signs of poor perfusion with hr less than ___ despite 100% and ventilations for 2 minutes .... Initiate _____
8 60 Chest compressions
402
Spinal immobilization Any pt ____ or ___ who has experienced a moi which could result in spinal injury
<5 or >65
403
Jfrd fire officer 1 has five categories
Instructor Management Written communications Emergency serviced (3 classes ) Technology IM WET
404
Each captain will furnish who with the test questions for rookies
Training division and their district /battalion chief
405
An accurate log containing names and contact info of ALL PERSONNEL ASSIGN TO THAT STATION shall be maintained by
Company officer
406
Problems with book info about reg protein foam
Says not recommended for class b fires but also says used only on hydrocarbon fuels
407
Whether the finished foam is used in either a med or hi expansion capacity is determined by
Type of application device used
408
Large diameter steel pipelines transport flammable nat gas at very high psi ranging from ____ to ____
200-1500 psi
409
In order to receive city or state incentive pay , yours submit a transcript to who
HR specialist 630-0227
410
Who carries several large caliber master streams for foam and dry chemical
Hazmat teams and station 37
411
Upon authorization from ______ , FRCC May alter dispatch protocols for the following reasons 1 2 3
HQ fire group supervisor Call volume Nature of call Storm conditions
412
At a hazmat incident , who is responsible for determining the on scene air requirements
The decon Officer .
413
In confined space : lifelines shall be attended by
One member per line Retrieval device should be in place before entry is made
414
The HEPA mask should not be REUSED if :
Becomes wet with water Body fluids or feces contact mask Damaged Older than 6 months Air exchange becomes difficult
415
If using fire 8 repeated on shipboard , which channel is used
C11
416
Like the U.S. ____ , the Canadian workplace hazardous materials information system requires that hazardous products be labeled and marked
HCS OSHA’s hazard communication standard
417
Pesticide label Pictogram a symbol inside a diamond with a ____ border
Red
418
When any equipment is noted as being lost found stolen or damaged in any way , it shall immediately be reported to ____ then they’ll tell ____ . That person will investigate and if necessary inform ______
CO district chief Division chief in writing
419
CO desiring to test hose in an out of service status must
Receive permission from FRCC and notify DISTRICT CHIEF Opposite of leaving first due territory in available status
420
Safe haven for newborns If Jfrd find actual or suspected child abuse they shall:
Provide ems to the newborn to extent trained Notify frcc for ccr and provide immediate transport to nearest hospital with ped services Immediately report to dcf and JSO JSO IS NOT INCLUDED ON 430 sog about abuse
421
Foam break down rapidly as the fuel temp rises and will perhaps become ineffective when fuels temp is near or over
150 degree f Not to be confused with film forming quality failing near 140
422
Qualifying exigency weird numbers
Rest and recuperation leave up to 15 days Post deployment activities within 90 days of coveted active duty
423
For additional leave after 12 weeks of Fmla submit the leave request to _______ and addtl docs sent to _____
Department director or designee City’s employee services medical section
424
Making a judgment regarding what is at risk , people or property , is perhaps the most important step in
Determining a risk profile
425
Defining the different control zones addresses the severity component of :
Avoidance
426
What is the most common abatement strategy for ergonomic stressors
Awareness
427
Acrocyanosis , cyanosis isolated to extremities : Saturation maybe remain less than normal for up to
10 minutes after birth
428
The original letter of counseling shall be forwarded to ____ then after review it shall be forwarded to the ______ in an envelope marked confidential .
District battalion chief Compliance officer . Only place where compliance officer is listed is in the counseling 330 SAP
429
Any Jfrd personnel who have a damage suit filed against them regarding line of duty shall immediately give copy to
Office of general counsel through chain They shall include full account of circumstances in question Only place where general counsel shows up . 100.05.01
430
Us DOT defines an elevated temp material as one that when offered for transport or transport in bulk packaging has one of following properties
Liquid phase at or above 212f Liquid phase with flashpoint at or above 100f that is intentionally kept above flashpoint Solid phase at a temp at or above 464f
431
The purpose of the GHS is to promote common consistent criteria for classifying chemicals according to their :
Health Physical And environmental hazards
432
304 Disciplinary action : the philosophy to be used is that of :
Progressive Cumulative Constructive
433
Facility hazardous materials list
Used to notify personnel or any additions or deletions of products /chemicals requiring msds
434
Chemicals other than those for personal consumption or hygiene that fall into hazmat category must receive approval from
Company officer or faculty manager
435
Who make INITIAL determination of whether or not a course is job related ? Who’s RESOLVES disputes regarding job relatedness ?
Div chief of training Head of talent management
436
____ stories or less requires type 1-b (3-3-2) Taller requires type 1-a (4-4-2)
11
437
In a hostage situation the engine company officer will ensure that the route is unimpeded by contacting :
Liaison officer (safety officer )
438
Open burning must be _____ away from road Residential land clearing must be _____ from any occupied building Commercial land clearing must be _____ from any occupied building
100’ 300’ 1000’ 0900- 1hr before sunset
439
Modern buildings may be used for many individual purposes including :
Assembly Institutional Mercantile Educational
440
Who carries spare bottles into high rise fire
Rat team and second squad .
441
During normal hours frcc will contact ____ to shut down power to monorail After hours contact _____ Unit will make sure the _______ has shut down power to monorail
Control center operator Skyway ops manager Control center operator
442
Ghosting is a hostile event warning sign , indicating potential for :