It is a structural system without complete
vertical local carrying space frame. (NSCP
208.20)
a.) Braced frame
b.) Bearing wall system
c.) Rigid component
d.) Concentric braced frame
b.) Bearing wall system
Is a component including its attachments having fundamental period less than or equal to 0.06 sec. (NSCP 208.20) a.) Braced frame b.) Bearing wall system c.) Rigid component d.) Flexible component
c.) Rigid component
Is a component including its attachments having fundamental period greater than 0.60 sec. (NSCP 208.20) a.) Braced frame b.) Bearing wall system c.) Rigid component d.) Flexible component
d.) Flexible component
Concrete filled driven piles of uniform section shall have a nominal outside diameter of not less than (NSCP 307.7.3) a.) 200 mm b.) 250 mm c.) 300 mm d.) 350 mm
a.) 200 mm
A complete record of test of materials and of concrete shall be available for inspection during the progress of work and \_\_\_\_\_\_\_ years after completion of the project and shall be preserved by the inspecting engineer or architect for that purpose, (NSCP 403.20) a.) 2 years b.) 5 years c.) 10 years d.) 15 years
a.) 2 years
The minimum bend diameter for 10mm Ø through 25mm Ø bars (NSCP 407.30) a.) 12 db b.) 6 db c.) 8 db d.) 10 db
b.) 6 db
The minimum bend diameter for 28mm Ø through 36mm Ø bars (NSCP 407.30) a.) 12 db b.) 6 db c.) 8 db d.) 10 db
c.) 8 db
The minimum clear spacing between parallel bars in a layer must be db but not less than? (NSCP 407.7.3) a.) 50mm b.) 25mm c.) 75mm d.) 100mm
b.) 25mm
In spirally reinforced or tied reinforced compression members, clear distance between longitudinal bars shall not be less than? (NSCP 407.7.3) a.) 2.0 db b.) 2.15 db c.) 1.50 db d.) 1.75 db
c.) 1.50 db
In walls and slabs other than concrete joist construction, primary flexural reinforcement shall not be spaced farther apart than 3 times wall or slab thickness nor farther than? (NSCP 407.7.5) a.) 375mm b.) 450mm c.) 500mm d.) 300mm
b.) 450mm
Groups of parallel reinforcing bars bundled in contact to act as one unit shall be united to \_\_\_ pieces in one bundle. (NSCP 407.7.6.1) a.) 4 b.) 3 c.) 2 d.) 5
a.) 4
Bars larger than \_\_\_mm shall not be bundled in beams: (NSCP 407.7.6.3) a.) 25mm b.) 16mm c.) 28mm d.) 36mm
d.) 36mm
Individual bars within a bundle terminated within the span of flexural members shall terminate at different points with at least \_\_\_\_ stagger: (NSCP 407.7.6.4) a.) 12 db b.) 10 db c.) 50 db d.) 40 db
d.) 40 db
Minimum concrete cover cast against and permanently exposed to earth: (NSCP 407.8.1) a.) 100 mm b.) 75 mm c.) 50 mm d.) 150 mm
b.) 75 mm
The minimum clear concrete covering for cast in place slab: (NSCP 407.8.1) a.) 20mm b.) 25mm c.) 40mm d.) 50mm
a.) 20mm
In ultimate strength design, the strength
reduction factor Ø for flexure without axial
loads: (NSCP 409.2.1)
a.) 0.85
b.) 0.75
c.) 0.90
d.) 0.70
c.) 0.90
In ultimate strength design, the strength
reduction factor Ø for shear and torsion:
(NSCP 409.4.2.3)
a.) 0.70
b.) 0.75
c.) 0.85
d.) 0.90
c.) 0.85
The minimum one way slab thickness which is simply supported at the ends only is: (NSCP 409.6.2) a.) L/20 b.) L/24 c.) L/28 d.) L/10
a.) L/20
The minimum one way slab thickness for a ONE end continuous slab is: (NSCP 409.6.2) a.) L/20 b.) L/24 c.) L/10 d.) L/28
b.) L/24
The minimum one way slab thickness for a BOTH ends continuous slab is: (NSCP 409.6.2) a.) L/20 b.) L/24 c.) L/10 d.) L/28
d.) L/28
The minimum cantilevered slab thickness is : (NSCP 409.6.2) a.) L/20 b.) L/24 c.) L/10 d.) L/28
c.) L/10
Deep continuous flexural members has overall depth to clear span ratio greater than: (NSCP 410.8.10) a.) 0.40 b.) 0.60 c.) 0.75 d.) 0.70
a.) 0.40
Deep simple span flexural members has overall depth to clear span ratio greater than: (NSCP 307.4.2) a.) 0.40 b.) 0.60 c.) 0.75 d.) 0.70
c.) 0.75
Spacing of shear reinforcement placed perpendicular to axis of non-prestressed member shall not exceed: (NSCP 411.6.4.1) a.) d/2 b.) d/4 c.) ¾ d d.) d/5
a.) d/2
Development length Ld for deformed bars in tension shall be less than: (NSCP 412.3.1) a.) 300 mm b.) 250 mm c.) 200 mm d.) 350 mm
a.) 300 mm
Is an essentially vertical truss system of the concentric or eccentric type that is provided to resist lateral forces: (NCSP 208.1) a.) Building frame system b.) Braced frame c.) Diaphragm d.) Collector
b.) Braced frame
Is a horizontal or nearly horizontal system activity to transmit lateral forces to the vertical resisting elements: a.) Building frame system b.) Braced frame c.) Diaphragm d.) Collector
c.) Diaphragm
Is a frame in which members and joints are capable of resisting forces primarily by flexure: a.) Moment resisting frame b.) Ordinary braced frame c.) Truss d.) Eccentric braced frame
a.) Moment resisting frame
In the determination of seismic dead load with a minimum of \_\_\_\_\_\_\_\_% of floor live load shall be applicable for storage and warehouse occupancies. (NSCP 208.5.1.1) a.) 50% b.) 25% c.) 30% d.) 35%
b.) 25%
The slope of cut surfaces shall be no steeper than \_\_\_\_\_\_\_% slope. (NSCP 302.2.2) a.) 50% b.) 60% c.) 30% d.) 40%
a.) 50%
Before commencing the excavation work, the person making the excavation shall notify in writing the owner of the adjoining building not less than \_\_\_\_\_days before such excavation is to be made. (NSCP 302.2.4) a.) 15 days b.) 10 days c.) 30 days d.) 60 days
b.) 10 days
Fill slopes shall not be constructed on natural slopes steeper than \_\_\_\_% slope (NSCP 302.3.1) a.) 50% b.) 10% c.) 20% d.) 60%
a.) 50%
The minimum distance that the toe of fill slope made to the site boundary line: (NSCP 302.4.3) a.) 0.80 M b.) 0.60 M c.) 1.50 M d.) 2.00 M
b.) 0.60 M
The max. distance that the toe of fill slope made to the site boundary: (NSCP 302.4.3) a.) 0.80 M b.) 0.60 M c.) 6.00 M d.) 1.00 M
c.) 6.00 M
In using sand backfill in the annular space around column not embedded in poured footings, the sand shall be thoroughly compacted by tamping in layers not more than \_\_\_\_\_mm in depth? (NSCP 305.7.3) a.) 500 mm b.) 400 mm c.) 200 mm d.) 300 mm
c.) 200 mm
In using a concrete backfill in the annular space around column not embedded in poured footings, the concrete shall have ultimate strength of \_\_\_\_Mpa at 28 days. (NSCP 305.7.3) a.) 30 Mpa b.) 15 Mpa c.) 10 Mpa d.) 5 Mpa
b.) 15 Mpa
When grillage footings of structural steel shapes are used on soils, they shall be completely embedded in concrete. Concrete cover shall be at least \_\_\_\_\_mm on the bottom. (NSCP 305.8) a.) 100 mm b.) 200 mm c.) 150 mm d.) 250 mm
c.) 150 mm
Temporary open air portable bleachers may be supported upon wood sills or steel plates placed directly upon the ground surface, provided soil pressure does not exceed \_\_\_\_Kpa. (NSCP 305.9) a.) 100 Kpa b.) 50 Kpa c.) 150 Kpa d.) 200 Kpa
b.) 50 Kpa
The minimum nominal diameter of steel bolts when wood plates or sill shall be bolted to foundation wall in zone 2 seismic area in the Philippines. (NSCP 305.60) a.) 10mm b.) 12mm c.) 16mm d.) 20mm
b.) 12mm