DCEN polarity is an arrangement where the work lead is connected to the negative terminal of the power supply?
- true
- false
false
For the SMAW process, which type of power supply is preferable?
- variable current
- constant voltage
- variable pulsing
- constant current
constant current
Excessive spatter and undercutting of a weld bead can be caused by:
- high current
- high voltage
- high arc length
- high travel speed
high current
When a power source is set to the high end of a low range how does the power source respond to a longer arc?
- increase current
- decreases current
- current is constant
- current is pulsed
decreases current
Select the correct statement about welding cables.
- voltage drop will decrease as diameter increases
- diameter must decrease as length increases
- diameter has little effect on current capacity
- diameter must increase as duty cycle decreases
voltage drop will decrease as diameter increases
When using an E4918 electrode, the arc is seen to be pulsing. What is the likely cause?
- cables too small
- arc too long
- power source on CV
- wrong polarity
wrong polarity
Select the correct statement about an E4918 (E7018) electrode.
- it should be kept in an electrode oven
- the minimum tensile strength is 550 MPa (80,000psi)
- it is suitable for the vertical down position
- it is suitable only for root passes in hardenable steels
it should be kept in an electrode oven
Which electrode is not suitable for overhead position welding?
- E6010/4310
- E6011/4311
- E7018/4918
- E7048/4948
E7048/4948
What is the effect of increasing current?
- more penetration
- narrower bead
- slower travel speed
- thicker slag cover
more penetration
Which electrode can be used to check for polarity?
- E7018
- E6011
- E6010
- 309L
E6010
An electrode holder is rated by which of the following?
- its voltage carrying capacity
- the diameter of the electrode it can hold
- size of the cable it is attached to
- its amp carrying capacity
its amp carrying capacity
Which electrode requires a relative humidity of 20 to 70% moisture?
- EXX18
- EXX28
- EXX10
- EXX15
EXX10
Which type of electrode should not be stored in a rod oven?
- cellulosic
- basic
- titania
- 309L
cellulosic
Electrodes should be stored in a rod oven at what temperature?
- 120 °C
- 212 °C
- 375 °C
- 450 °C
120 °C
Electrodes that are exposed to the environment for more than 4 hours should be?
- rebaked at 650 °C
- thrown out
- rebaked at 450 °C
- rebaked at 370-430 °C or as recommended by the manufacturer
rebaked at 370-430 °C or as recommended by the manufacturer