Review #3 Flashcards

1
Q

The maximum permitted length of a fixture outlet pipe is

A

1200 mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The outside water, sanitary and storm drain piping is shown on the ____ plan

A

Site plan

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Measurements for floor heights and drop ceilings, for rough in purposes, are taken from the building _________ drawing

A

Cross sectional elevation drawing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Which of the following tests may be used on a completed job to test the fixture settings
A. Water test
B. Air test
C. Vacuum test
D. Final test

A

D. Final test

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The minimum temperature required in the water supply to a commercial dishwasher, to ensure bacteria kill is

A

82 ‘C (180 ‘F)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When water runs continually into the overflow tube in a water closet tank, the fault is likely in the ___ valve

A

Ballcock valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Which of the following traps are not permitted
A. A trap with a trap seal depth less than 100mm
B. A drum trap
C. A “p” trap
D. A bell trap

A

D. A bell trap

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the maximum number of 90 degree bends which may be used on the trap arm from a water closet?

A

Two

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The minimum size of a yoke vent, used in conjunction with a vent stack, shall not be less than

A

The smallest pipe to which it is connected

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Number of FU allowed to drain to the lower end of a vent stack is

A

8 FU

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

In reference to a hot water heating system, the type of air vent required to be used on an inaccessible main would be a ____ vent

A

Float vent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

A hydro massage tub has which of the following?
A. A 2” trap
B. Jets above the water line
C. Correctly sized supply lines
D. One vacuum breaker

A

C. Correctly sized supply lines

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The type of copper most used in a residential hot water heating system is type ____

A

Type M

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

The type of copper tube found in the radiation of a hot water heating system is type ___

A

Type H

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The length of a standard pipe wrench is measured between

A

The face of the heel jaw and the end of the handle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

To prevent overflow in a sink that is not fitted with an integral overflow, it is accepted to use a

A

Standing waste

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

The maximum number of water closets that may drain to a 3” SOWS is

A

6

18
Q

What is the minimum distance a vent may terminate from a property line, other than a property line adjacent to a street?

A

1.8m

19
Q

When indirect wastes connect fixtures on three or more storeys, they must have a vent that

A

Terminates separately

20
Q

An invert elevation would be an elevation at the ____ of the pipe

A

Bottom inside

21
Q

The maximum distance allowed from the trap to the vent is measured from

A

Trap weir to vent fitting

22
Q

What is the minimum permissible arm length for an unvented 3” floor drain?

A

18” (450 mm)

23
Q

What is the minimum horizontal distance that a vent may terminate from an opening window?

A

3.5 m

24
Q

What is the minimum distance that a flow meter should be installed from a fitting?

A

5 pipe diameters upstream
10 pipe diameters downstream

25
Q

What is the minimum distance a vent pipe shall terminate above a roof?

A

6” (150 mm)

26
Q

What is the minimum distance any vent may terminate above ground?

A

2m

27
Q

Minimum distance a vent may terminate above an opening door or window, or an air inlet if the vent is too close horizontally?

A

1m

28
Q

Minimum size of a clean out on a 4” branch

A

3”

29
Q

An expansion tank for a hot water heating system should be able to accommodate what extra percentage of volume for expansion of water?

A

3%

30
Q

A pipe that is connected at its bottom end to a fixture drain and serves a number of fixtures is called a _____ vent

A

Circuit

31
Q

The type of heating system most likely to be used in an apartment building would be a ____ return

A

Reverse

32
Q

The most upstream valve on a water service is the

A

Corporation cock

33
Q

Which type of copper tube is only produced as hard-drawn type?

A

Type DWV

34
Q

The type of copper tubing not permitted for vent and drain lines is ____ drawn types ____

A

Soft drawn types K and L

35
Q

An end switch is a component of which type of heating control?

A

Zone valve

36
Q

If there is a vent on the flow control fitting, where should this vent terminate?

A

Tee it back to the general venting system

Flow control (grease interceptor)

37
Q

Water is the most dense at

A

4 ‘C (39 ‘F)

38
Q

The minimum size of a sump vent is

A

2” (max 4”)

39
Q

What may allow a fixture to self-siphon?

A

Trap too far below fixture

40
Q

What is the maximum permitted flow rate to a shower head?

A

7.6 litres/min

41
Q

Except for column showers, what is the minimum dimension between two adjacent shower heads?

A

750 mm (2 1/2 feet)