Residential Installations and Codes (110104h) Flashcards
B149.1-05 CAN/CSA gas code
Applies from the ground all the way to appliances.
NBC & ABC
National building code.
Alberta building code.
National oil heating code.
Covers installation of oil burning equipment.
All furnaces installed in Alberta are certified by who?
CSA (Canadian standards association)
Common vent.
Needs to be installed so it permanently maintains all clearances to combustibles.
Base plate.
Main purpose is to stop any fire that may travel inside the chase that the vent is in.
Hanging the furnace
Big No
Understand heating
Always slope back to the furnace.
Must be securely positioned using metal stakes.
Hanger length for supply and return duct.
3 inches longer then the die of the duct for supply for 1 inch clearance.
2 inches long for return air duct so it is snug to the roof.
B-vent clearance from combustibles
1 inch
L-vent (oil burning) clearance from combustibles
3 inches
A-vent and super A-vent clearance from combustibles
2 inches
Single wall vent and double wall vent clearances
6 inches for single wall.
1 inch for double wall.
Solid fuel burning appliances with single wall venting need what for clearance?
18 inches of clearance.
Clearance for exterior hoods from gas regulator.
1 meter for inlet or exhaust vent.
3 meters for moisture exhaust vents.