Where there is a bank elevator system (more than one car to a shaft), the keyways are usually located in the shaft doors on what floors?
Basement
First Floor
Top Floor
What must be designated and assigned to monitor the structure for any further movement that may indicate a secondary collapse?
Look Outs
All members operating within how many feet of the edge of a body of water, or anywhere accidental entry is possible, must wear a proper fitting U.S. Coast Guard approved personal flotation device (PFD) or ice rescue suit?
10’
Turnout gear/PPE, including firefighting helmets, will not be worn within how many feet of a body of water, even if the member is wearing a personal flotation device (PFD), during a Water and Ice Rescue Incident?
20’
A throw bag line utilizing an under-hand throw aimed at the victim’s chest area is effective up to approximately?
60’
If possible, a minimum of how many much space should be between the rescuer and the path of an un-deployed airbag?
10-15 inches
When responding to a structural collapse incident, units, with the exception of the first due Engine Company, shall initially stage at one location a minimum of how far from the incident?
1500’
What forces are usually the result of vertical loads caused by gravity pushing on floor slabs and beams?
Bending forces
On single shaft elevators, the key-ways are usually located in the shaft doors on what floors?
Each floor including the basement
On a structure collapse incident, what does 1 long air horn blast for about 3 seconds mean?
Evacuate the Area?
Stop all operations/QUIET
If entry is to be made into a confined space with an SCBA, the entrant(s) are permitted to move no farther than how far from the entrance?
25 feet
What is the minimum acceptable PPE for all personnel on all rope rescue incidents?
Helmets and gloves
On a high angle rescue all personnel operating at or within how many feet of the edge of any height shall be tethered to an anchor point?
5’
Responding companies shall position apparatus no closer than how many feet to the trench/excavation?
200’
Who is a member qualified to be stationed outside of the confined space who monitors authorized entrants and performs other specified duties?
Rescue attendent
“River Right” is the right hand bank of a moving body of water when facing which direction?
Downstream
How far should the exclusionary zone extend from the water’s edge at a water rescue incident?
20’
Air bags inflate at speeds up to:
200MPH
What is the minimum staging distance for a Structural Collapse incident
1500’
At a structural collapse incident, the Truck Company shall eliminate sources of vibration within what distance?
500’
Which victims should be removed first at the scene of a structure collapse?
A. Those located on the surface or lightly buried
Which air horn sequence at a structure collapse signals “Evacuate the Area”?
3 short blasts about 1 second each