Regulations Flashcards
____ and/or _________ in a water supply can discolor laundry, cause a bad taste in the water, and cause taste problems in beverages such as coffee and tea.
Iron and/or Manganese in a water supply can discolor laundry, cause a bad taste in the water, and cause taste problems in beverages such as coffee and tea.
Water systems that collect less than __ coliform samples each month can have 1 positive sample and remain in compliance.
Water systems that collect less than 40 coliform samples each month can have 1 positive sample and remain in compliance.
The maximum contaminant level for bromate is _____ mg/L.
The maximum contaminant level for bromate is 0.010 mg/L.
____ _______ is the best available technology for removing radium-226 and radium-228 from a water supply.
Lime softening is the best available technology for removing radium-226 and radium-228 from a water supply.
Water systems must provide at least _____ removal or inactivation of Giardia lamblia cysts between a point where the raw water is not subject to recontamination by surface water runoff and a point downstream before or at the first customer.
Water systems must provide at least 3-log removal or inactivation of Giardia lamblia cysts between a point where the raw water is not subject to recontamination by surface water runoff and a point downstream before or at the first customer.
Water systems must provide at least ____ removal or inactivation of viruses between a point where the raw water is not subject to recontamination by surface water runoff and a point downstream before or at the first customer.
Water systems must provide at least 4-log removal or inactivation of viruses between a point where the raw water is not subject to recontamination by surface water runoff and a point downstream before or at the first customer.
Color gives the water an unappealing appearance and indicates that _______ _______ may be present.
Color gives the water an unappealing appearance and indicates that dissolved organics may be present.
For water systems using conventional treatment or direct filtration, the turbidity level of representative samples of a system’s filtered water must be less than or equal to ___ NTU in at least 95% of the samples collected each month.
For water systems using conventional treatment or direct filtration, the turbidity level of representative samples of a system’s filtered water must be less than or equal to 0.3 NTU in at least 95% of the samples collected each month.
A public water system that does not provide filtration must have a disinfection concentration in the distribution system, measured as total chlorine, combined chlorine, or chlorine dioxide, which cannot be undetectable in more than _% of the samples each
A public water system that does not provide filtration must have a disinfection concentration in the distribution system, measured as total chlorine, combined chlorine, or chlorine dioxide, which cannot be undetectable in more than 5% of the samples each
Systems using diatomaceous earth filtration are required to have turbidity levels ___ ntu in __% of the measurements collected each month.
Systems using diatomaceous earth filtration are required to have turbidity levels ≤1.0 ntu in 95% of the measurements collected each month.
Lab analysis of pH, turbidity, temperature, and residual disinfectant concentrations must be performed by a person approved by the ____.
Lab analysis of pH, turbidity, temperature, and residual disinfectant concentrations must be performed by a person approved by the state.
Either the _____ or a _____ _______ certifies water treatment plant laboratories for the measurement of total coliforms, fecal coliforms, and heterotrophic plate counts.
Either the USEPA or a state agency certifies water treatment plant laboratories for the measurement of total coliforms, fecal coliforms, and heterotrophic plate counts.
The time from sample collection to initiation of the fecal coliform analysis may not exceed _ hours.
The time from sample collection to initiation of the fecal coliform analysis may not exceed 8 hours.
Samples to be analyzed for total coliforms by the total coliform Fermentation Technique, must be kept below __ degrees Celsius during transit.
Samples to be analyzed for total coliforms by the total coliform Fermentation Technique, must be kept below 10 degrees Celsius during transit.
Utilities collecting samples more frequently than annually for inorganic contaminants determine MCL compliance by calculating a ______ ______ _______ at each compliance sample point.
Utilities collecting samples more frequently than annually for inorganic contaminants determine MCL compliance by calculating a running annual average at each compliance sample point.