Re-Fresher #2 Flashcards
An emergency shut off valve may be installed between a pressure vessel and the emergency discharge valve only under certain conditions. T or F?
F
Feeder protection for freon hermetic compressor must never exceed 225% of FLA according to the Canadian electrical code. T or F?
F
Oil failure control protects compressor against loss of oil lubrication by sensing two pressures: crankP and pumpP to achieve netPoilP. This works on principle of heat and bi-metal action. T or F?
T
backward inclined fan is all known as a no load or non overloading fan. True or False?
T
A dual element fuse is used to protect a compressor motor from excessive starting current only. True or False?
F
Voltages that can be obtained from a delta closed distribution transformer are 208/1/60, 208/3/60, 240/3/60, 120/1/60. T or F?
F
The reversing valve as used with a heat pump system should be replaced after a system burnout of 0.5or greater has occurred. T or F?
T
Normal compression ratio for a centrifugal compressor is 5:1. T or F?
F
For accurate readings of liquid line moisture indicators its temp should be 70degF. T or F?
F
Refrigerant 12 driers should be at least 3-5 times as large as driers used for refrigerant 22 or 500. True or False?
F
A CRO is used to control condenser pressure during periods of low ambient temperatures (below 70f) on air cooled condensers. T or F?
F
With direct staging compression systems cooling of freon vapour between the discharge of 1st and inlet of second comp is needed.
T or F?
F
Calcium chloride may be stored in the same equipment room as ammonia as long as it is safe to do so. T or F?
F
Copper and brass is always used with ammonia gas because of their non-corrosive action in the presence of moisture. T or F?
F
Calculation for COP is Btu’s output/kw input x 3425. T or F?
F
A direct acting controller means that, an increase in output energy, as it senses an increase in controlled variable. T or F?
T
Temp sensors of the electrical resistance type will always have a positive temperature coefficient. T or F?
F
Protection for branch circuit feeding a refrigeration hermetic compressor should be sized at _____ of RLA
a) 110%
b) 125%
c) 140%
d) 225%
B
A perfect vacuum can be expressed by what pressure?
a) 0psig
b) 0psia
c) 29.4” hg vac
d) 10 microns
B
The capacity of an evaporative condenser/cooling tower is
a) greater when wet bulb temp is low
b) greater when wet bulb temp is hi
c) lower when wet bulb is low
d) greater when humidity is higher
A
A liquid receiver must be capable of storing what percentage of a system charge?
a) 125%
b) 120%
c) 110%
d) 90%
D
Efficiency of a compressor could be stated as
a) how cold suction line is compared to discharge
b) how hot condenser is
c) diff between high and low gauge
d) none of the above
D
What is the safety device located and installed on a gauge glass level indicator in case of breakage?
a) hand valve
b) solenoid valves
c) ball check pins
d) ball check valves
D
A sample evap coil operates at a design TD of 8F. What will the relative humidity in the condition space?
a) 80-90%
b) 70-80%
c) over 90%
d) 90%
C
Normal face velocity or air flow across a unit cooler?
a) 1500-2000fpm
b) 500-600fpm
c) under 500fpm
d) over 500fpm
B
Oversizing evaporator system effects
a) higher humidity
b) lower humidity
c) make unit efficient
d) bring space temp down in less time
B
capacity of a fin and tube evap is controlled by?
a) compressor unloaders
b) coil splitting
c) vary air flow
d) none of the above
B
To achieve stable shell and tube evap control what system characteristic is required?
a) constant air or water flow
b) constant water flow
c) constant air flow
d) proper metering device
B
Temp rise above ambient for a motor?
a) 40c
b) 40f
c) raise of 32f
d) raise of 32C
A
If you have a lower pressure switch that is equipped with a range adjustment screw, what part of the control must be adjusted first?
A
Why would you install two pressure relief valves in parallel on a large capacity system?
a) Valve too close to inside walls of building
b) When two valves needed to service
c) when one valve capacity is not enough
d) all of the above
B
How can water quality be controlled in a cooling tower used for condenser water?
a) adding required impurities
b) ensuring bleed off entering is right
c) ensuring bleed off leaving is right
d) all of the above
C
What is standard air conditon when dealing with ac systems?
a) 72f
b) 70f
c) 68f
d) none
B
Instrument used to check insulation value of an electric motor
a) ohm meter
b) amp metrer
c) megohm meter
d) volt meter
c
What is the purpose of a liquid line solenoid as used with refrigeration system installations?
a) prevents flooding during operation of compressor
b) prevents flash gas in liquid line
c) used on pump down systems
A
Current relay coil is located
a) in series with compressor start winding
b) in series with compressor run winding
c) across start and run winding
d) parallel with run winding
B
If you purge a system with nitrogen and some remains when the process is complete and the system starts up
a) low head pressures
b) system will operate in vacuum
c) high head pressures
d) low back pressure and high head pressure
C
thicker valve plate used on compressor. what happens to eff%?
a) decrease
b) increase
c) stays same
d) nothing
a
If suction pressure was to increase and discharge to remain same, what would happen to compressor capacity?
a) increase
b) decrease
c) stay same
d) nothing
A
On a rotary compressor a check valve is installed on the _______ to prevent equalization in the off cycle
a) liquid line
b) suction line
c) discharge line
C
Ol failure control operates on the principle of?
a) heat and bi metal action
b) temperature
c) pressure
d) time and manual operation
A
A commercial refrigeration system has 10F fluctuation in suction pressure.
a) evap is over sized
b) evap is under sized
c) expansion vale is under sized
d) expansion valve oversized
D
Why would you use a compressor equipped with automatic unloaders?
a) increase capacity on demand
b) decrease capacity on demand
c) vary system capacity on demand
d) never use automatic unloaders
C
What two metals used in refrigeration work can cause electrolysis?
a) copper and brass
b) brass and steel
c) steel and nickel
d) copper and steel
D
The body if a gas charged TXV should be placed in a ______ location than the actual sensing bulb
a) warmer
b) colder
a)