Conditioned air is distributed to:
Cockpit, fwd and aft cabins
Hot air fault light illuminates on the air conditioning panel
The hot air press. reg. valve closes and the trim air valves close.
Does the trim air provide the warm air or the cold air to the air conditioning system?
Warm air
In case of zone controller primary and secondary channel failure, what temperatures are maintained by pack one and pack two?
20 deg.C for pack one and 10 deg.C for pack two
In normal flight in closed circuit configuration, the avionics ventilation system controls the temperature of the cooling air by:
Passing air through a skin heat exchanger.
To enable Ram air to the mixer unit, The Ram air switch should be used:
Only when differential pressure is less than 1 psi.
Pack controller, primary channel failure.
The secondary computer operates as a backup mode and regulation is not optimized
Pack controller, secondary channel failure
No effect on pack regulation backup mode is lost
Pack controller, primary and secondary channel failure
Pack outlet temperature is controlled to between 5 and 30 deg.C by the anti-ice valve
Hot air press. reg. valve failed open:
No effect
Bleed air supplied from the APU (APU bleed valve open), the pack flow is automatically selected:
High
Trim air valve, each one optimizes the temperature by:
Adding hot air
Hot air pressure regulating valve:
Regulates the pressure of hot air tapped upstream of the packs
Pack flow control valve:
Is pneumatically operated and electrically controlled
Engine flow demand, when the heating or cooling demand in one zone cannot be satisfied:
The minimum idle is increased automatically
What is the Norm.Max. cabin altitude?
8,000 ft
What is the Max. negative Diff. pressure for the cabin?
1 psi.
It is permissible to use simultaneously packs and Lp ground unit during long stops in a hot airfield
No
What are the different sources of air for air conditioning and pressurization?
Engine bleed air and recirculated air, or if selected, APU bleed air and recirculated air.
During the exterior preflight on a warm day, in what position would you expect to find the avionics ventilation system INLET and EXTRACT valves to be in?
Open.
What happens to the pack flow control valves during engine start?
They automatically close.
The temperature of each aircraft zone is optimized by means of:
A TRIM AIR valve.
When does normal pressurization occur?
Pressurization occurs during the takeoff roll.
When does normal depressurization occur?
It is complete 1 minute after touchdown.
Under what conditions should the pack flow controller be set to LO?
With a low passenger load to reduce bleed air demand and improve fuel efficiency.
Which statement is correct regarding illumination of the amber AFT ISOL VALVE fault light?
Means that either the inlet or outlet isolation valve(s) disagrees with the switch position.
Pressurization controllers receive inputs from:
LGCIU, ADIRU, FMGS, and EIU.
What computers control the cabin and cockpit conditioned air?
One zone controller that passes information and instructions to two pack controllers for three zones.
When would you select RAM AIR ON?
Dual pack failure or smoke removal.
What happens when a temperature selector rotary knob is adjusted?
A signal is sent to the zone controller requesting a different temperature.
With APU BLEED ON and engine BLEED switches ON with engines running, what is the position of the engine bleed valves?
Closed
Pressurization is normally automatic. Can you interfere with it?
Yes, CABIN PRESS MODE SEL to OVERRIDE and MAN V/S CTL toggle switch.
Under what conditions should the pack flow controller be set to HI?
With a high passenger load in hot conditions in order to help reduce the cabin temperature.
What is the function of the ram air valve?
Emergency smoke removal and ventilation in the event of dual pack failure.
Placing the EXTRACT push button to override:
Insures the extract fan will continue to be energized.
The Ram Air valve:
Must be manually activated.
What limitation is associated with the ram air valve?
Do not open if cabin pressure is greater than 1 psi.
With the pressurization system in the automatic mode, which valves are closed when the ditching push button is selected on?
All valves below the water line.
What is the maximum negative differential pressure for the cabin?
1 psi.
The HOT AIR valve push button controls:
The hot air manifold.
Both pressurization auto controllers are set by the active flight plan loaded in the MCDU. The QNH entry on the MCDU Approach Performance page refines the depressurization schedule for the landing.
True.
Aft cargo indications may be found on which ECAM page(s)?
The ECAM cruise page and the COND page.
Avionics ventilation system indications may be found on which ECAM page(s)?
Only the CAB PRESS page.
When APU is supplying the packs, the pack controller sends a demand signal to increase airflow when a zone temperature cannot be satisfied. This signal is sent to the:
APU ECB.