FCOM Flashcards
Temperature Regulation is controlled by
Zone controller and two pack controller
Pack Operation is controlled by
Pack controller signal
Pack Flow Control Valve
is pneumatically-operated and electrically-controlled
How pack flow control valve regulates the air flow?
In accordance with signal received from pack controller
The pack flow control valve closes automatically in case of
pack overheating, engine starting, fire or ditching pushbutton
What RAM AIR does?
ventilates the cockpit and cabin to remove smoke , or if both pack fails
When RAM AIR pb is ON:
The outflow valve opens about 50% provided that it is under automatic control and P is less than one PSI
Hot-Air Pressure-Regulating Valve
is pneumatically-operated and electrically-controlled
Hot-Air pressure regulative valve closes automatically in case of
- The Duct overheats
- The cockpit trim air valve fails
- Both cabin trim air valves fail
Trim air valves are
electrically-controlled by the zone controller
how pack controller regulates the temperaturee
Each pack controller regulates the temperature of its associated pack, in accordance with a demand signal from the zone controller,by modulating the bypass valve and the ram air inlet flaps
When ram air inlet flaps close during TO
when TO power is set
main landing gear struts are compressed
When ram air inlet flaps closes during Landing
as soon as main landing gear struts are compressed,
as long as speed is at or above 70knots
When ram air inlet flaps open after landing
They open 20 seconds after the speed drops below 70 knots
When pack flow controller delivers high flow?
- in single pack operation
- when the APU is supplying bleed air
What is EIU
Engine Interface Units
Where are the temperature sensors
- in the cockpit, for the cockpit zone
- in the lavatory extraction circuit and galley ventilation system for the cabin
The Temperature selection range is
18’C to 30’C, middle 24’C
Zone Controller Primary channel fails
The flow setting function and optimized temperature regulation are not available
Hot AIR and TRIM AIR valve closes
The zones are controlled to 24’C
Pack1 controls the cockpit temp
Pack2 controls the FWD and AFT cabin temp
ALTN MODE appears on the ECAM COND page
Zone Controller Secondary Channel Fails
This has no effect on zone temperature regulation
Backup mode is lost
Zone Controller Primary and Secondary channel fails
Optimized and backup temperature regulation is lost
The pack deliver a fixed temp
20’C for Pack 1
10’C for Pack 2
The fialure removes all information from the ECAM COND page, which then displays PACK REG
Pack Controller Primary Channel Fails
The secondary computer operates as a backup
Regulation is not optimized
Pack flow is fixed at the previous setting
Pack Controller Secondary Channel Fails
This failure has no effect on pack regulation
Backup mode is lost
ECAM signals related to the corresponding pack are lost
Pack Controller Primary and Secondary channel fails
As a backup, corresponding pack outlet temperature is controlled by the ANTI-ICE valve
Temperature between 5’C and 30’C in a maximum of 6 minutes
What is ACM
Air Cycle Machine
HOT AIR pressure regulating valve failure
Failed Open: no Effect
Failed Closed: optimized regulation is lost, Trim air valves are driven to the full closed position.
Pack 1 controls the cockpit temperature to the selected value
Pack 2 controls the cabin temperature to the mean value
TRIM AIR valve failure
Optimized temperature regulation of the corresponding zone is lost