Quiz 1/chap 6 text/Mod 1 Flashcards

1
Q

What type of reaction do you suppose would be indicated by the following?

A) endothermic reaction
B) exothermic reaction
C) level control
D) pressure control

A

A) endothermic reaction

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Refer to the previous question (reactor vessel). What device would produce a 20 bit asynchronous output word?

A) TY
B) TV
C) PT
D) TT

A

D) TT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Refer to the previous question (reactor vessel) once again. The manipulated variable is;

A) feed in
B) product out
C) condensate
D) flow rate of steam

A

D) flow rate of steam

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Refer back to the previous question (reactor vessel). The manipulated variable is measured.

A) True
B) False

A

B) False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

An example of primary sensing element is:

A) a signal conditioner
B) an I/P
C) a temperature element
D) a thermowell

A

C) a temperature element

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What device compares two signals?

A) a final control element
B) a transmitter
C) a sensing element
D) a controller

A

D) a controller

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The LRV and URV of a process that ranges from 300C to 500C, and represented by a standardized pneumatic transmitter would be:

A) 4mA = 300C 20mA = 500C
B) 4mA = 300C 20mA = 200C
C) 3 psi = 300C 15 psi = 500C
D) 0 psi = 300C 15 psi = 500C

A

C) 3 psi = 300C 15 psi = 500C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

We have a 0-100 psi process signal; which is to be represented by a 4-20 mA standardized signal. Would we use a controller to perform this conversion?

A) True
B) False

A

B) False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The zero and span for a process that ranges from 300C to 500C would be:

A) zero = 4mA span = 20mA
B) zero = 300C span = 200C
C) zero = 300C span = 500C
D) zero = 3 psi span = 15 psi

A

B) zero = 300C span = 200C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

If we bypass the controller in a control loop, we say the process is under:

A) automatic control
B) manual control
C) self regulating control
D) remote control

A

B) manual control

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The manipulated variable in a home heating system would be:

A) the gas flow to the burner
B) the heat generated in the firebox
C) the ambient temperature in the house
D) the desired temperature set at the thermostat

A

A) the gas flow to the burner

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

According to ISA a process is defined as:

A) an operation which involves a change in energy, state or composition.
B) the control system that maintains a setpoint value.
C) a physical system that is ready to receive energy
D) a migration from one state to another.

A

A) an operation which involves a change in energy, state or composition.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The target value of the process is called:

A) the measurement variable
B) the controlled variable
C) the controller output
D) the setpoint

A

D) the setpoint

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

A device that converts 4-20 mA to 3-15 psi is called a:

A) sensing element
B) controller
C) final control element
D) converter

A

D) converter

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The following indicates that:

A) the process is out of control
B) the process is properly controlled
C) a lot of noise in the process loop
D) the control valve is fixed at 50%

A

B) the process is properly controlled

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Pressure, level and temperature are all examples of:

A) process variables
B) disturbance variables
C) controller output values
D) standardized output signals

A

A) process variables

17
Q

The variable that is required to be controlled is called:

A) process variable
B) manipulated variable
C) disturbance
D) measurement variable

A

A) process variable

18
Q

What do you notice about the following?

A) the water level is too low to be sensed
B) the steam pressure too high
C) the LT is producing a 4-20 mA signal
D) the water level is too high

A

A) the water level is too low to be sensed

19
Q

Refer back to the previous question again (steam drum). What type of standardized signal do you notice?

A) 4-20mA
B) 3-15 psi
C) wireless
D) digital

A

B) 3-15 psi

20
Q

Refer to the previous question (steam drum) and refer only to what you see. What important control and measurement components are missing from the boiler system shown?

A) a controller
B) the steam drum
C) a level transmitter
D) make up water

A

A) a controller