Question 2:
At MUD, members of your unit were discussing the use of a rearmount aerial ladder with a ladder pipe. They were correct in all of their statements except in which choice?
A: Salt water shall never be used in drills
B: Maximum extension of ladder with 1 1/2” tip is 100 ft
C: Maximum pressure is 90 psi for a solid stream nozzle
D: When the street has a severe crown, insure the ladder angle does not exceed 70 degrees
B.
80 ft
Question 1: A newly promoted Lieutenant would be correct to know that the First Responder's Bridge Manual "Field Guide" is what color? A: Orange B: Red C: Green D: Blue
C. green
Question 3:
Company Commanders shall assign CFR-D certified members to groups that ensure the greatest likelihood that how many of these certified FFs will report for duty on any given tour?
A: 1
B:2
C:3
D: 4
B. 2
Question 4:
Prior to the arrival of the FAST Unit, the IC has the discretion to designate a number of units/members for possible assistance or rescue. Which choice below is not entirely correct in describing the units/members at the IC’s discretion for this task?
A: Safety Team
B: Companies held in reserve
C: Companies/members available for immediate reassignment
D:Chauffeurs or chief’s aides
D.
Explanation:
D) UNCOMMITTED chauffeurs or FULL DUTY aides
FFP MMID ch 4 3.1
Question 5:
Officers shall ensure that 2 CFRD firefighters will be working each tour. If necessary to ensure this, who shall the officer notify for needed details prior to the start of the tour?
A: DSCO
B: Division
C:Battalion
D: Any unit within the Battalion with surplus CFRD members
C
Question 6:
As a Captain working your first tour in the 14th Division, you are surprised to find out that you have incurred an asbestos situation in quarters. In this scenario you would be correct to make which of the following notifications during office hours?
A: Haz-Mat Unit
B:OSHA Coordinator
C:Building Maintenance Division
D: Battalion
C.
Explanation:
After office hours telephone the Notification Desk instead of the Building Maintenance Division
Reqs & Payroll 1.10.5
Question 7:
You are a CFRD certified officer working in Engine 405. One of your CFRD certified on-duty members has been granted medical leave during the tour due to a line-of duty injury. This leaves your unit with the ECC, who is CFRD certified, and the Nozzle and Control firefighters who are not CFRD certified. In this scenario you would be most correct to know that your unit should be?
A: Out of service for fire duty and CFRD responses
B: In service for fire duty but out of service for CFRD responses
C: Out of service for fire duty but in service for CFRD responses
D:In service for both fire duty and CFRD responses
D
CFR ch 2 1.8 Note
Question 8:
Only a Staff Chief may approve a Vacate Order. For residential vacates, if the DC determines that structural or life safety conditions permit, ___ hour(s) should be granted to allow occupants to prepare for relocation.
A:1
B:6
C: 4
D: 2
B
BISP ch 4 4.5
Question 9:
As the officer working the day tour in Staten Island, you would know that all of the following apply for an OOS PSS except?
A: A replacement PSS will be delivered from the Division since they have 10 for immediate assignment should one be required.
B: While working in a ladder company, you responded “Understaffed” because two members had their PSS OOS.
C: A maximum of 4 engine and 4 ladders could be an initial response if 2 of the engines and 2 of the ladders responded with less than 4 firefighters.
D: While working in an engine company, you responded “Understaffed” because two members and the officer had their PSS OOS.
D Explanation: Ropes 4 A. sect 6.1, 6.2 B. sect 6.14 C. AUC 287 Add 1 sect 6.2 D. sect 6.15 When a Company Officer is in need of a replacement PSS, the unit where that member is working shall inform the borough dispatcher that the unit is OUT OF SERVICE until a replacement PSS is obtained from the Division Depot.
Question 10:
While responding to a reported structural fire in a place of public assembly, you notice “PG” as the FD designation in the CIDS message. You would be correct to know that, at a minimum, this building will be the scene of a familiarization drill at least?
A:Once a year
B:Twice a year
C: Once every two years
D: Once every three years
A
AUC 345 5.1
Question 11:
According to the taxpayer bulletin, on rules for sprinkler protection, under the 2008 building code, which of the following statements is incorrect in regards to an occupancy within a building needing a sprinkler system?
A:Occupancy within a building in which the area exceeds 7,500 square feet needs a sprinkler
B:An area of any size located 2 stories above grade needs a sprinkler
C: Occupancy within a building of any size needs a sprinkler in a high rise building
D: Area of any size contains an unenclosed stair or escalator connecting two or more floors
B Explanation: A. FFP Taxpayers 2.5.1 B An area of any size is located 3 stories above grade 2.5.1 C 2.5.1 D 2.5.1
Question 12:
The nylon tubular webbing shall be inspected after each use and at what other time?
A: Weekly
B:Monthly
C: Semi-annually
D: Annually
B
Explanation:
FFP MMID ch 3 Add 3 6.2
Question 13:
You are the officer of the first due engine responding to a possible radiological situation in a UPS truck. On arrival, you use the Rad50 and receive a reading of 2mR/hr one meter from a package. The package has a label with a Transport Index of 1mR/hr. You would know which is incorrect?
A: This is a radiological emergency, not a radiological incident.
B: If the event is considered intentional, the Fire Marshals shall be special called for additional security and crime scene preservation.
C: Any area that causes the Rad50 to alarm requires confirmation by a second radiation meter.
D:The Hotline is the edge of the Hot Zone. A warm zone is a specific area near the edge of the hotline, usually superimposed in the cold zone which encircles the source of radiation.
D
Explanation:
ERP Add 4.
A.This would be considered a Radiological Emergency because the readings are above the Transport Index. sect 2.3, 2.3.1.B
B. sect 3 pg 9
C. sect 4.2 - 1st bullet
D. sect 4.4.2.C - A warm zone does not encircle the source of radiation.
Question 14:
Positive Pressure Fans issued to Hi-Rise Units and select Ladder Companies shall be inspected and started at what times?
A: At the beginning of every tour and ran at full RPM weekly at MUD for 5 minutes
B:Daily at the beginning of the 9X6 tour and ran at full RPM weekly at MUD for 5 minutes
C: Daily at the beginning of the 9X6 tour and ran at full RPM weekly at MUD for 15 minutes
D: At the beginning of every tour and ran at full RPM weekly at MUD for 15 minutes
B
Question 15:
According to Dunn, which statement is incorrect regarding the collapse of buildings under construction?
A: If the building on fire is exposing the crane, the IC must setup a collapse zone equal to the height of the crane.
B: The strategy for fire in cast in place structures should be defensive using outside aerial streams to protect exposures from fire spread and extinguish the fire from a safe distance.
C: A floor collapse can occur anytime during construction and can trigger a multilevel floor collapse of the entire building.
D:Outside aerial master streams are the recommended strategy to extinguish fire in formwork supporting floors. All FF’s should be removed to floors below during this operation.
E: Shanties are required to be noncombustible. Portable heaters too close to combustibles are the number one ignition source with other ignition sources being illegal smoking, matches and careless cooking .
D Explanation: Dunn Ch 16. A. Crane Collapses p83 B. Cast In place structures p84 C. Concrete Collapse - of Cast In Place buildings p84 D. Outside aerial master streams are the recommended strategy to extinguish fires in formwork supporting floors. All FF's should be REMOVED FROM THE BUILDING during this operation.p86 E. Worker Shanty Fires p85