How long will your tanks supply last using the Rosenbauer project II if the tank is not augmented?

A

2 mins

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Pumps & Pumping

Why is it important that the air is dumped before using the pump?

A

It tilts the tank towards the pump improving pump effiency

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Pumps & Pumping

When should the compound gauge be monitored?

A

During all pumping operations

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Pumps & Pumping

How long will your tanks supply last using the Rosenbauer SelectFlow RB101 if the tank is not augmented?

A

3 minutes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Pumps & Pumping

When three lights are illuminated on a Series II Mercedes water tank contents indicator, the auto fill valve is….?

A

Fully open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Pumps & Pumping

What is the maximum distance between pumps when using 90mm hose on level ground?

A

90mm hose - 15 lengths

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Pumps & Pumping

When working from a hydrant, what actions should be taken when the autofill valve is set to open, the flow meter has a zero reading & the hosereel tank is half full?

A

Open the emrgency bypass valve which is located in the o/s rear locker

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Pumps & Pumping

What is the pressure loss rate for all hose due to gravity?

A

0.1 bar per metre

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Pumps & Pumping

What would be the FIRST sign of an appliance autofill valve failing in the closed position?

A

The tank contents would fall below three quarters and the flow gauge would continue to register zero

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Pumps & Pumping

Once the pump bypass lever has been engage how much water will be supplied direct to the tank?

A

1000 litres per minute

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Pumps & Pumping

You are connected to an Aerial (ALP/TL) or dry riser, what is the maximum pressure you would charge them to?

A

10 bar

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Pumps & Pumping

What is an appliance pump’s default pumping pressure setting?

A

High pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Pumps & Pumping

How many Litres/min will be delivered through the hosereel @ 35 bar?

A

100

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Pumps & Pumping

Why should the pump operator switch to low pressure mode as soon as hose reel jets are not required?

A

The maximum available low pressure flow rate may be impaired if high pressure mode remains selected when it is not required

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Pumps & Pumping

When four lights are illuminated on a Series II Mercedes water tank contents indicator, how many litres of water are in the appliance tank?

A

Approximately 1350 litres

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Pumps & Pumping

What are the frictional loss rates for 70mm delivery hose?

A

0.2 Bar per length @ 500 l/min

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Pumps & Pumping

A full tank of fuel will allow an appliance to pump for approximately how long?

A

4 hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Pumps & Pumping

What size hose is used for water relaying by pumping appliances?

A

90mm hose and 70mm hose

19
Q

Pumps & Pumping

With one hose reel jet in use approximately how long will a full tank of water last?

A

Approx 15 minutes

20
Q

Pumps & Pumping

What should the pump operator do if the autofill valve fails in the fully closed position?

A

Pull the bypass lever in the offside rear locker to divert water directly to the tank

21
Q

Pumps & Pumping

How far from the hydrant should the initial pump be?

A

As close as possible to receive maximum flow from hydrant, and no more than 3 lengths and always twinned. Every additional length reduces flow to pump.

22
Q

Pumps & Pumping

What pressure range does the Rosenbauer SelectFlow RB101 operate?

A

3 to 6 bar

23
Q

Pumps & Pumping

What is the optimum pressure /flow rate for the Rosenbauer Project II branch set to solid core jet?

A

7 Bar & 630 l/min

24
Q

Pumps & Pumping

What does the high pressure gauge indicate?

A

Water pressure being delivered to the hose reel jets

25
# Pumps & Pumping A sudden decrease in pressure at the low pressure gauge could indicate what?
A burst delivery hose length
26
# Pumps & Pumping What is the maximum working pressure of delivery hose?
15 Bar
27
# Pumps & Pumping When three lights are illuminated on a Series II Mercedes water tank contents indicator, how many litres of water are in the appliance tank?
Approximately 1000 litres
28
# Pumps & Pumping How do we connect 90mm to a pumping appliances?
90mm Storz hose tail adaptors
29
# Pumps & Pumping What is the maximum distance between pumps when using 70mm hose on level ground?
8 lengths
30
# Pumps & Pumping A sudden increase in pressure on the low pressure gauge could indicate what?
A branch being closed
31
# Pumps & Pumping When should the compound gauge be monitored?
During all pumping operations
32
# Pumps & Pumping How can a hydrants flow rate be assessed?
Drop tank level until 2 lights are illuminated and turn on auto fill valve digital display
33
# Pumps & Pumping What is the main fire brigade pump used on appliances and lightweight portable pumps?
A centrifugal pump
34
# Pumps & Pumping What pressure range does the Rosenbauer Project II operate?
3.5 to 7 bar
35
# Pumps & Pumping What should the pump operator do when the reversing alarm sounds?
Check the cab
36
# Pumps & Pumping When lifting from open water what is the maximum theoretical and maximum practical lift possible?
Max theoretical: 10 metres Max practical: 8 metres
37
# Pumps & Pumping How many lengths of twinned 90 mm hose can pumps be apart in a water relay on an uphill gradient ground?
12
38
# Pumps & Pumping What is the optimum pressure /flow rate for the Rosenbauer SelectFlow RB101 branch set to solid core jet?
6 Bar & 400 l/min
39
# Pumps & Pumping You are the pump operator of an appliance connected to a hydrant by twin 70mm hose and supplying a single 45mm jet. Your appliance tank is full, how could you tell if the Autofill valve has failed in the closed position?
Flow meter reads zero, water tank contents lights start to flash and then go out, hydrant hose is rock hard.
40
# Pumps & Pumping What are the frictional loss rates in 45mm delivery hose?
1 bar per length
41
# Pumps & Pumping What will cause the pump bay switches to return to their default setting?
Appliance being placed in drive or the PTO being disengaged
42
# Pumps & Pumping Why does delivery No1 have a lesser performance than the others?
There is a bend in the pipe making No1 less efficient
43
# Pumps & Pumping What does the compound gauge indicate?
The pressure of the water supply coming into the pump, with a vacuum reading (negative pressure) when lifting from open water and a pressure reading (positive pressure) when the supply is augmented from a hydrant.
44
# Pumps & Pumping What should the pump operator do when the thermal relief valve operates?
Open an outlet slightly