Pumps & pumping Flashcards
Any mistakes or suggestions on improvements please contact Phil Simpson
Pumps & Pumping
How long will your tanks supply last using the Rosenbauer project II if the tank is not augmented?
2 mins
Pumps & Pumping
Why is it important that the air is dumped before using the pump?
It tilts the tank towards the pump improving pump effiency
Pumps & Pumping
When should the compound gauge be monitored?
During all pumping operations
Pumps & Pumping
How long will your tanks supply last using the Rosenbauer SelectFlow RB101 if the tank is not augmented?
3 minutes
Pumps & Pumping
When three lights are illuminated on a Series II Mercedes water tank contents indicator, the auto fill valve is….?
Fully open
Pumps & Pumping
What is the maximum distance between pumps when using 90mm hose on level ground?
90mm hose - 15 lengths
Pumps & Pumping
When working from a hydrant, what actions should be taken when the autofill valve is set to open, the flow meter has a zero reading & the hosereel tank is half full?
Open the emrgency bypass valve which is located in the o/s rear locker
Pumps & Pumping
What is the pressure loss rate for all hose due to gravity?
0.1 bar per metre
Pumps & Pumping
What would be the FIRST sign of an appliance autofill valve failing in the closed position?
The tank contents would fall below three quarters and the flow gauge would continue to register zero
Pumps & Pumping
Once the pump bypass lever has been engage how much water will be supplied direct to the tank?
1000 litres per minute
Pumps & Pumping
You are connected to an Aerial (ALP/TL) or dry riser, what is the maximum pressure you would charge them to?
10 bar
Pumps & Pumping
What is an appliance pump’s default pumping pressure setting?
High pressure
Pumps & Pumping
How many Litres/min will be delivered through the hosereel @ 35 bar?
100
Pumps & Pumping
Why should the pump operator switch to low pressure mode as soon as hose reel jets are not required?
The maximum available low pressure flow rate may be impaired if high pressure mode remains selected when it is not required
Pumps & Pumping
When four lights are illuminated on a Series II Mercedes water tank contents indicator, how many litres of water are in the appliance tank?
Approximately 1350 litres
Pumps & Pumping
What are the frictional loss rates for 70mm delivery hose?
0.2 Bar per length @ 500 l/min
Pumps & Pumping
A full tank of fuel will allow an appliance to pump for approximately how long?
4 hours
Pumps & Pumping
What size hose is used for water relaying by pumping appliances?
90mm hose and 70mm hose
Pumps & Pumping
With one hose reel jet in use approximately how long will a full tank of water last?
Approx 15 minutes
Pumps & Pumping
What should the pump operator do if the autofill valve fails in the fully closed position?
Pull the bypass lever in the offside rear locker to divert water directly to the tank
Pumps & Pumping
How far from the hydrant should the initial pump be?
As close as possible to receive maximum flow from hydrant, and no more than 3 lengths and always twinned. Every additional length reduces flow to pump.
Pumps & Pumping
What pressure range does the Rosenbauer SelectFlow RB101 operate?

3 to 6 bar
Pumps & Pumping
What is the optimum pressure /flow rate for the Rosenbauer Project II branch set to solid core jet?
7 Bar & 630 l/min
Pumps & Pumping
What does the high pressure gauge indicate?
Water pressure being delivered to the hose reel jets

