Pumps Chapter 5 Flashcards
From the Pump Manual:
How many types of service tests are used for Class A pumpers?
Three
From the Pump Manual:
The three hour test conducted by Underwriter’s Laboratories at a manufacturer’s plant is called a _______ test.
Listing
From the Pump Manual:
When is the Acceptance test conducted?
When new apparatus is received by the purchaser
From the Pump Manual:
What is the duration of the standard Acceptance test?
Three hours
From the Pump Manual:
During the standard Acceptance test, what is the duration of the full capacity testing portion?
Two hours
From the Pump Manual:
What are the two capacities tested in half hour portions during the standard Acceptance test?
7/10 capacity and 1/2 capacity
From the Pump Manual:
The DCFD requires the standard ______ hour Acceptance test when writing the specifications for the purchase of pumping apparatus.
Three
From the Pump Manual:
All pumping apparatus in service or reserve shall be tested at least ______ each year and after ______ ______ ______, to determine their condition.
once, any extensive repairs
From the Pump Manual:
Annual service tests shall consist of drafting with a lift of no more than ______ feet.
Ten
From the Pump Manual:
What is the annual service test net pump pressure and duration of the full capacity portion?
150 psi, 20 minutes
From the Pump Manual:
What is the annual service test net pump pressure and duration of the 7/10 capacity portion?
200 psi, 10 minutes
From the Pump Manual:
What is the annual service test net pump pressure and duration for the 1/2 capacity portion?
250 psi, 10 minutes
From the Pump Manual:
Where are annual service tests conducted?
Training Academy
From the Pump Manual:
Annual service tests are conducted under the supervision of members of which two Divisions?
Training Division and Fleet Maintenance Division
From the Pump Manual:
Testing after extensive repairs will be conducted where and by whom?
At Fleet Maintenance by personnel from the Fleet Maintenance Division