Private Dwellings Flashcards

1
Q

What is the major weakness from a firefighting protection standpoint in a private dwelling?

A

open and unenclosed stairway

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Where will the inside cellar stairs usually be found in a semi-attached structure or those with minimal space on one side?

A

found near the side or rear entrance

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The presence of dormers on the second floor usually increases the likelihood of what? Where is the easiest access to these rooms via portable ladders?

A

2nd floor bedrooms

through the windows on the exposure 2 & 4 side of the house

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Which types of private dwellings have ballon frame construction as the most common?

A

Straight line colonials and Queen Annes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Some flat roof private dwellings have decorative peaks in the front, possibly masking the fact that the roof is actually flat. What may be an indication of a flat roof when you see a peak in the front:

A

The absence of a window in the peak

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Any private dwelling with lightweight construction __________ be entered into the CIDS program.

A

MUST

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

One indication of a private dwelling (carnarsie tenement) with two in the front and three in the rear is what?

A

If there is no garage located in the front, then a community driveway may be present in the rear providing for easy access

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The interior of split level homes may have as many as __________ levels within a 3-story building.

A

FIVE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Possible indications of attic occupancy may be: an attic area with a dormer, adequate height of approximately _________ feet in the attic

A

SEVEN

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Widows with sills that are approximately chest high may require a drop of _____-______ feet to floor level. Upon entering, consider placing a dresser, chair, or another piece of furniture belwo this window to assit in egress.

A

5-6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Outside ladder company positions are predicated on whether a roof is flat or peaked. This information _______ be transmitted with the signal 10-75, if it can be determined.

A

MUST

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The primary consideration for the placement of the first hoseline at a PD fire is?

A

through the front door for the protection of both the interior stairs and the members conducting searches above the fire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

When a private dwelling is fully involved and/or when a wind impacted fire may be encountered, what hoseline should be considered?

A

2 1/2”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is a quick determination of a structure whether or not it is ballon frame?

A

Remove a baseboard on an exterior wall (inside the house) and check for the presence of a sole plate. NO SOLE PLATE = BALLOON FRAME

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

In platform construction, the exterior walls studs extend from the floor to the ceiling of each individual floor. What are they capped with at the ceiling level of each floor?

A

Horizontal 2” x 4” called a top plate (or bottom plate)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What type of construction would you find a ribbon-ledger board in?

A

Ballon frame construction

17
Q

Which ladder company will attempt an examination of the cellar for fire, perform a primary search of the perimeter, and perform roof ventilation of flat roof buildings?

A

1st Ladder to arrive

18
Q

Which ladder company will perform roof ventilation of a peak roof (if needed), will ensure roof ventilation of a flat roof PD, ensure the cellar is examined for fire, and SHUT DOWN THE UTILITIES?

A

2nd Ladder to arrive