Powerplant Flashcards
What is on the accessory gearbox. Where is it located?
S.H.O.F
Starter generator,hydraulic pump,oil pump,h.p. Fuel pump and f.c.u.
Bottom of engine between axial and centrifugal compressors.
What kind of engines?
Willams FJ44-2C. Medium bypass turbine.
Describe the starting sequence.
Pressing the start button closes the starter relay,arms ignition,activtes boost pump,turns flood lights to full bright and the start button illuminates. At 8 to 10% n1 &n1 rotation throttle is advanced triggering ignition and within 10 sec light occurs. When 45% n2 is achieved starter becomes a gen and ignition as well as boost pumps shut off.
What is the total oil capacity, when should you check it? What is the consumption limitation?
Total capacity is 4 qts. Check within 10 min. of shutdown. Max consumption is .023 gallons every ten hours~a qt.
When does the oil filter button pop?
If contaminants cause more than 15 psi differential pressure.
What causes a red oil pressure light?
A 25 psi pressure switch.
How is oil pressure sensed?
Through a resistence bulb sending analog to a dcu sent to edc turned digital to mfd