Power Plant Operation Flashcards

1
Q

RPM normal operating range (tachometer green arc)

A

700-2800

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Min RPM during engine runup idle check

A

975

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Min “area idle” RPM

A

1400

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Min RPM during operations with fuel pump off

A

1400

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Min permissible full-throttle static RPM during engine runup

A

2000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Max permissible continuous RPM if an IFT student is PF

A

2700

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Max permissible continuous RPM (tachometer red line)

A

2800

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Min RPM drop during magneto check

A

25

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Max RPM drop during magneto check

A

150

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Max RPM drop difference between magnetos

A

50

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Max permissible continuous engine power (BBP)

A

125

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Min oil pressure (psi)

A

10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Oil pressure normal operating range (psi)

A

30-60

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Maximum time for oil pressure to reach 10 PSI after start (sec.)

A

30

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Maximum oil pressure for full power operation if OAT < 0°C (psi)

A

70

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Maximum oil pressure (psi)

17
Q

Minimum oil temperature (F)

18
Q

Maximum RPM after start until oil temp indication registers

19
Q

Oil temperature normal operating range (F)

20
Q

Minimum oil temperature to begin an area SFL at area idle (F)

21
Q

Minimum oil temperature for full power operation if oil pressure is normal (F)

22
Q

Maximum oil temperature (F)

23
Q

Minimum oil quantity (US qts)

24
Q

Maximum oil quantity (US qts)

25
Fuel pressure lower limit red line (psi)
3.5
26
Fuel pressure upper limit red line (psi)
16.5
27
Maximum continuous starter operation (sec)
10
28
Maximum cumulative starter operation before a 3 to 5 minute cooling (sec)
30
29
Maximum time for CHT below 300°F in decent (minutes)
5
30
Minimum CHT takeoff and descent (F)
240
31
CHT normal operating range (F)
300-420
32
CHT caution range (F)
420-460
33
Maximum CHT (F)
460
34
Maximum OAT operation with full winterization kit (C)
0
35
Maximum oh a T operation with partial winterization kit (C)
12.5