Pneumatics and air conditioning Flashcards

1
Q

In auto what controls compartment temperature?

A

The lowest compartment temp. Other compartments will use trim air to increase temp .

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

In standby what temperature is N C W

A

N 75.
C65
W 85 F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

When pack has failed off how do you get back on.

A

Push reset

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

If inop light on what does the pack do?

A

Temp valve fails in the last position and pack works in a degraded mode.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

When does high flow come on in pack.

A

When on the ground with external air

When in the air when one pack off or recirc off

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What happens when the high stage light come on.

A

HP valve closes .requires maintenance action.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What happens with a bleed light on?

A

Bleed valve closes due high temp.

Can be reset by pushing bleed off then on if temperature reduced

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Reason for isolation valve light on?

A

Fails to open or close to commanded position.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What happens when a recirc fan fails or is switched off?

A

The corresponding pack will go to high flow.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Where is the air go to from the recirc fans.

A

To the mix manifold

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

How many equipment cooling fans are there and how many work at the same time.?

A
3 fans 
Supply
Alternate
Auxiliary 
Only 1 operates at one time.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

When does the overboard exhaust valve from the Eand E bay open and close.

A

When diff is 2.5 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What happens to the overboard exhaust valve when the left pack fails.

A

It opens and provides circulation due to differential pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

How many fans in aft equipment and how many work at once.

A

2 fans only one works at a time other is automatically switched on if other fails.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Equipment cooling overheat light on when.

A

Supply fan inop,alternate fan inop ,exhaust duct failed, recirc fan inop.
Basically when no circulation due to above.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

If equipment cooling o/h light remains on after selecting to alternate .what is most likely cause?

A

Both aft equipment fans have failed.

17
Q

Smoke in left recirc duct causes?

A

Left recirc fan to switch off
O/B exhaust valve opens
Left pack goes to high flow.

18
Q

Smoke in the supply duct causes what?

A

Both recirc fans off
Both packs to high flow
Supply fans turned off.

19
Q

What is the temperature range of the packs in auto

A

18 to 30 c

20
Q

How many zones in cabin.

A

Felt deck
Forward
Aft
3 all up .