What is the minimum size of a secondary stack vent in a commercial building serving a 3” soil stack?
1 1/2”
What is the maximum number of circuit vented branch traps that can be installed between a circuit vent and a relief vent?
8 traps
What is the minimum size of a relief vent?
One size smaller then the circuit vent
The National Plumbing Code is a set of written standards which:
set minimum standards
What is the minimum size individual vent serving a 4” trap?
1 ½”
What is the maximum length of a 3” trap arm serving a floor drain at minimum grade?
3.75m (12’)
When is a backwater valve required?
on fixtures below grade
The flow from a pump into a storm drainage system is taken as:
1 L/s = 900 L
What size storm building drain is required for a flat roof of 20m long and 18m wide at 1 in 100 slope?
6”
What size leader is required for a flat roof of 11m long and 20m wide?
4”
What CCC protection is required for the Washdown Ventilation Hood?
RP
The Flight Machine (A) has an operating temperature of 77 deg C for pumping water through equipment for at least ___________.
5 MIN
What is the minimum size branch discharging from the Food Display Sink?
1 1/4”
What are the names of the R’s in the food prep sink?
Non-concealed standing wastes
According to the plumbing code, what would be the fixture unit load for a flow rate of 12 imperial gallons per minute?
29 fu’s
What is the purpose of the Orifice Flow Control Plate (M)?
CONTROL THE LAMINAR FLOW INTO THE TRAP
What is the maximum number of flush tank water closets that could drain from the fifth storey into a 3” soil stack?
4
Piping that is too low to drain by gravity into the sanitary building drain is called:
Sub drainage piping
How is the size of a vent for a sewage pump determined?
one size smaller than the largest inlet, at least 2” but no more than 4”
When sizing a combined sewer, how do you convert from FU to litres?
260 FU and more multiply by 9.1, under 260 is counted as 2360