plumbing code Flashcards
An act to regulate the trade of Master Plumber.
RA 1378
What do you call to this device that is being used to circulate
hot water to the plumbing system?
a. overhead feed
b. up feed
c. pump circuit system
d. hot water recirculating pump
hot water recirculating pump
Shall not act in an unprofessional manner and demand any remuneration other than his/her original charges except for additional services not covered in the basic contract.
a. Code of Ethics No. 1
b. Code of Ethics No. 3
c. Code of Ethics No. 5
d. Code of Ethics No. 7
Code of Ethics No. 1
What is the minimum number of LAV for 200 males? (Assembly Places - Theatres, Auditoriums, Convention Halls, etc. - for permanent
employee use)
5
Shall not advertise in self-laudatory language, act in any manner an engage in any practice which tend to bring dishonor to the
dignity of the Registered Master Plumber, the National Master Plumbers association of the Philippines (NAMPAP) and the plumbing
profession.
a. Code of Ethics No. 1
b. Code of Ethics No. 3
c. Code of Ethics No. 5
d. Code of Ethics No. 7
Code of Ethics No. 7
It shall be unlawful for any person, firm or corporation, whether acting as principal, servant, agent or employee, to do or cause to be done any plumbing or drainage work for which a permit is required without securing prior permit from the Office of the Building Official having jurisdiction under the _____.
a. DPWH
b. DILG
c. City Mayors
d. All of the above
All of the above
The invert of the inlet pipe shall be at a level not less than ____ above the invert of the outlet pipe.
a. 32 mm
b. 38 mm
c. 40.8 mm
d. 50.8 mm
50.8 mm
The inlet compartment of any septic tank shall be _____ of the total capacity of the tank, nor less than 2.0 m3 liquid capacity.
not less than two-thirds
The pipe or tubing that connects the outlet of a plumbing fixture to the trap.
a. trap
b. trap arm
c. tailpiece
d. outlet
tailpiece
Shall not allow the use of his/her license as registered Master
Plumber for a fee to an unlicensed Master Plumber in plumbing works without his/her personal supervision.
a. Code of Ethics No. 1
b. Code of Ethics No. 3
c. Code of Ethics No. 5
d. Code of Ethics No. 7
Code of Ethics No. 5
What is the minimum width of the inlet compartment of a septic tank?
a. 600mm
b. 750mm
c. 900mm
d. 1500mm
900mm
It refers to the resistance delivered by streaming water with fittings and inside surface of the pipe.
a. force
b. friction
c. pressure
d. velocity
Friction
Consists of two independently acting internally loaded check
valves, a differential pressure relief valve, four properly located test cocks and two isolation gate valves.
RP
Distribution boxes shall be designed to insure ____ flow and shall be installed on a level concrete slab in natural or compacted soil.
a. equal
b. less
c. more
d. none of the above
Equal
To receive the discharge from aeration, what is installed at the bottom portion of the soil stack where the house drain is connected?
a. aerator
b. deaerator
c. Sovent system
d. ventilation
deaerator
Airgap less than 25 mm shall only be approved as a permanent part of a listed assembly that has been tested under actual backflow conditions with vacuums of from
a. 0 to 65 cm. of mercury
b. 0 to 36 cm. of mercury
c. 0 to 60 cm. of mercury
d. 0 to 63.5 cm. of mercury
0 to 63.5 cm. of mercury
Fixture outlets shall not be connected to the horizontal excreta drainage piping system within how many meters from any vertical to horizontal change of direction of a stack containing suds-
producing fixtures.
a. 3.0m
b. 2.4m
c. 1.2m
d. 1.5m
2.4 m
It is a piece of a framework that expels sewage and greywater from a building and controls pneumatic stress in the waste-framework channels to help free stream.
a. Sanitary sewer system
b. Storm sewer
c. DWV system
d. Vent system
DWV system
Where two or more drain lines are installed, an approved _____ of
sufficient size to receive lateral lines shall be installed at the head of each disposal field.
a. distribution box
b. seepage pit
c. septic tank
d. disposal field
distribution box
A hose connection with two-gated outlets permitting two connections of the same or smaller coupling diameter to be taken from a single supply line.
a. Wye
b. Tee
c. Sanitary tee
d. 1/8 bend
Wye
All sections of a plumbing drainage and vent system must be tested with
a. water
b. any liquid
c. air or water
d. air
air or water
The inverts of all outlets shall be level and the invert of the inlet shall be at least ____ above the outlets.
a. 25.4 mm
b. 50.8 mm
c. 101.6 mm
d. 104.6 mm
50.8 mm
That portion of a building included between the upper surface of any floor and the upper surface of the floor next above.
a. Branch
b. Storey
c. Riser
d. Stack
Storey
The requirements for installation of grease interceptors exclude
a. fast-food restaurants
b. apartment buildings with up to 100 dwelling units
c. hospitals
d. hotels
apartment buildings with up to 100 dwelling units