plumbing code Flashcards

1
Q

An act to regulate the trade of Master Plumber.

A

RA 1378

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What do you call to this device that is being used to circulate
hot water to the plumbing system?

a. overhead feed
b. up feed
c. pump circuit system
d. hot water recirculating pump

A

hot water recirculating pump

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Shall not act in an unprofessional manner and demand any remuneration other than his/her original charges except for additional services not covered in the basic contract.

a. Code of Ethics No. 1
b. Code of Ethics No. 3
c. Code of Ethics No. 5
d. Code of Ethics No. 7

A

Code of Ethics No. 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the minimum number of LAV for 200 males? (Assembly Places - Theatres, Auditoriums, Convention Halls, etc. - for permanent
employee use)

A

5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Shall not advertise in self-laudatory language, act in any manner an engage in any practice which tend to bring dishonor to the
dignity of the Registered Master Plumber, the National Master Plumbers association of the Philippines (NAMPAP) and the plumbing
profession.

a. Code of Ethics No. 1
b. Code of Ethics No. 3
c. Code of Ethics No. 5
d. Code of Ethics No. 7

A

Code of Ethics No. 7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

It shall be unlawful for any person, firm or corporation, whether acting as principal, servant, agent or employee, to do or cause to be done any plumbing or drainage work for which a permit is required without securing prior permit from the Office of the Building Official having jurisdiction under the _____.

a. DPWH
b. DILG
c. City Mayors
d. All of the above

A

All of the above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The invert of the inlet pipe shall be at a level not less than ____ above the invert of the outlet pipe.

a. 32 mm
b. 38 mm
c. 40.8 mm
d. 50.8 mm

A

50.8 mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The inlet compartment of any septic tank shall be _____ of the total capacity of the tank, nor less than 2.0 m3 liquid capacity.

A

not less than two-thirds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The pipe or tubing that connects the outlet of a plumbing fixture to the trap.

a. trap
b. trap arm
c. tailpiece
d. outlet

A

tailpiece

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Shall not allow the use of his/her license as registered Master
Plumber for a fee to an unlicensed Master Plumber in plumbing works without his/her personal supervision.

a. Code of Ethics No. 1
b. Code of Ethics No. 3
c. Code of Ethics No. 5
d. Code of Ethics No. 7

A

Code of Ethics No. 5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the minimum width of the inlet compartment of a septic tank?

a. 600mm
b. 750mm
c. 900mm
d. 1500mm

A

900mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

It refers to the resistance delivered by streaming water with fittings and inside surface of the pipe.

a. force
b. friction
c. pressure
d. velocity

A

Friction

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Consists of two independently acting internally loaded check
valves, a differential pressure relief valve, four properly located test cocks and two isolation gate valves.

A

RP

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Distribution boxes shall be designed to insure ____ flow and shall be installed on a level concrete slab in natural or compacted soil.

a. equal
b. less
c. more
d. none of the above

A

Equal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

To receive the discharge from aeration, what is installed at the bottom portion of the soil stack where the house drain is connected?

a. aerator
b. deaerator
c. Sovent system
d. ventilation

A

deaerator

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Airgap less than 25 mm shall only be approved as a permanent part of a listed assembly that has been tested under actual backflow conditions with vacuums of from

a. 0 to 65 cm. of mercury
b. 0 to 36 cm. of mercury
c. 0 to 60 cm. of mercury
d. 0 to 63.5 cm. of mercury

A

0 to 63.5 cm. of mercury

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Fixture outlets shall not be connected to the horizontal excreta drainage piping system within how many meters from any vertical to horizontal change of direction of a stack containing suds-
producing fixtures.

a. 3.0m
b. 2.4m
c. 1.2m
d. 1.5m

A

2.4 m

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

It is a piece of a framework that expels sewage and greywater from a building and controls pneumatic stress in the waste-framework channels to help free stream.

a. Sanitary sewer system
b. Storm sewer
c. DWV system
d. Vent system

A

DWV system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Where two or more drain lines are installed, an approved _____ of
sufficient size to receive lateral lines shall be installed at the head of each disposal field.

a. distribution box
b. seepage pit
c. septic tank
d. disposal field

A

distribution box

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

A hose connection with two-gated outlets permitting two connections of the same or smaller coupling diameter to be taken from a single supply line.

a. Wye
b. Tee
c. Sanitary tee
d. 1/8 bend

A

Wye

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

All sections of a plumbing drainage and vent system must be tested with

a. water
b. any liquid
c. air or water
d. air

A

air or water

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

The inverts of all outlets shall be level and the invert of the inlet shall be at least ____ above the outlets.

a. 25.4 mm
b. 50.8 mm
c. 101.6 mm
d. 104.6 mm

A

50.8 mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

That portion of a building included between the upper surface of any floor and the upper surface of the floor next above.

a. Branch
b. Storey
c. Riser
d. Stack

A

Storey

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

The requirements for installation of grease interceptors exclude

a. fast-food restaurants
b. apartment buildings with up to 100 dwelling units
c. hospitals
d. hotels

A

apartment buildings with up to 100 dwelling units

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Tube made of plastic material and colored black. The cross-sectional shape is normally oval and is denoted by its outside diameter or O.D. Normally used as water service connection from main to meter. a. Polyethylene b. Polybutylene c. PVC d. PVDF
Polybutylene
26
A valve actuated by stem screw, and hand wheel, suited on installation that calls for throttling. a. foot valve b. gate valve c. angle valve d. globe valve
globe valve
27
The 22 basic Principles of master plumbing is enumerated in what section of RA 1378?
Section 5
28
The pressure existing without any flow motion.
Static pressure
29
What is the minimum of number of water closet required at office with 20 persons?
1
30
What is the minimum number of WC for 100 males? (Assembly Places - Theatres, Auditoriums, Convention Halls, etc. - for public use)
1
31
What is the minimum pressure used in water test for drainage system?
10 ft head
32
All water supply, drainage, venting system and all fixtures and their traps complete with their connection.
plumbing system
33
It is the required pressure to test water supply system.
150% of used water pressure
34
Inlet and outlet pipe fittings or baffles, and compartment partitions shall have a free vent area _______ of the house sewer or private sewer discharging therein to provide free ventilation above the water surface from the disposal field or seepage pit through the septic tank, house sewer, and stack to the outer air. a. equal to the required cross-sectional area b. 1.5 times the required cross-sectional area c. twice the required cross-sectional area d. 2 1⁄2 times the required cross-sectional area
equal to the required cross- sectional area
35
What is the slope of a waste pipe with a minimum size of 3” horizontal pipe?
1⁄4 inch per foot
36
What is the minimum size of water supply pipe to a lavatory?
10 mm
37
A branch vent that performs its functions for two (2) or more traps.
group vent
38
On what date the National Plumbing Code of the Philippines was approved?
January 28, 1959
39
What is the minimum pressure required to test water supply system?
150% of used water pressure
40
The part of the plumbing system extending 0.6 m from the inner face of the foundation wall of the building to the junction with another sewer a. house sewer b. storm sewer c. sanitary sewer d. building drain
house sewer
41
What is the minimum size of p-trap for floor drain?
2”
42
Allowing for friction and other pressure loss the available water pressure for fixture is ____________.
15 psi
43
What is the maximum fixture unit loading allowed on 51-inch waste stack?
sixteen
44
That part of plumbing system extending from point 0.6-m of the inner face of the foundation wall of building to the junction with another sewer. a. house sewer b. storm sewer c. sanitary sewer d. building drain
house sewer
45
The drainage system or any part thereof shall not be covered until a. After a plumbing inspector has been called b. It has been tested c. It has been inspected d. It has been approved
It has been approved
46
Cast iron piping is 10 ft length installed horizontally, shall be supported at intervals of not more than ______.
10 ft
47
The air test for a plumbing drainage and vent system shall be made by attaching the air compressor or other test apparatus to a. The lowest fixture outlet available b. The highest vent opening c. Any suitable opening d. A dishwasher waste opening
Any suitable opening
48
The waste pipe from a domestic dishwashing machine connected to a food-waste disposer unit must have a/an _______. a. Soft-seat check valve b. Approved air-gap fitting c. Backflow preventer valve d. Nonrising stem gate valve
Approved air-gap fitting
49
The drainage pipe running from outside a buildings foundation to the main sewer.
Sewer
50
To ensure effectiveness, the wastes entering the grease interceptor must not exceed the manufacturer’s rated capacity. For this reason, a ______ must be installed.
flow control
51
A freestanding drinking fountain may connect to the drainage system of a building _________. a. by using an approved air-gap fitting b. by an indirect waste method c. through an individual p-trap only d. provided the waste outlet is no more than 10 feet from a vent
by an indirect waste method
52
Is a device located at the bottom of the tank for the purpose of flushing water closet and similar fixtures
Flush valve
53
The scope of plumbing practice is enumerated in what section of the Plumbing Law?
Section 2
54
Joints in lead pans or liners shall be ______.
burned
55
The lowest portion of the interior part of any pipe or conduit that is not vertical
Invert
56
Where there is exposure to skin contamination with poisonous, infectious, or irritating materials, provide one lavatory for
each five persons
57
The side walls shall extend at least ___ above the liquid depth.
228.6 mm
58
Any joint or seam obtained by the joining of metal parts in a plastic molten state. a. welded joint b. seam c. both a & b d. none of the above
both a & b
59
Joints in copper pans or liners shall be ______. a. Soldered b. Brazed c. either a or b d. neither
either a or b
60
All whirlpool bathtubs shall comply with the following requirements, except a. a removable panel of sufficient dimension shall be provided for access to the pump b. the circulation pump shall be located below the crown weir of the trap c. the pump and the circulation piping shall be self-draining to minimize water retention d. suction fittings on whirlpool bathtubs shall comply with the listed standards
the circulation pump shall be located below the crown weir of the trap
61
A baffle type fitting shall have the equivalent cross-sectional area of the connecting sewer pipe and not less than a ____ horizontal dimension when measured at the inlet and outlet pipe inverts.
106.6 mm
62
Horizontally installed piping must be supported at sufficiently close intervals to ________.
prevent sagging
63
All piping installed in corrosive type material shall be ________.
protected properly
64
A trap depending on movable parts to retain its seal may _______.
not be used under any circumstances
65
What do you call to the combination of two elements, hydrogen and oxygen?
water
66
What is the maximum distance allowed for the trap of the floor drain to be placed below the finished floor line to facilitate cleaning in case of line trouble?
600 mm
67
Equipment which includes all valves and controls used in the plumbing system which are required to be accessible or readily accessible.
Regulating Equipment
68
The inlet and outlet pipe or baffle shall extend _____ above and at least 304.8 mm below the water surface.
101.6 mm
69
Distribution boxes shall be coated on the inside with a ______ or other approved method acceptable to the Administrative Authority.
bituminous coating
70
The size of a trap arm may change direction without the use of a cleanout when such direction does not exceed 90 degrees.
Less than 76mm diameter
71
Cleanouts on the seal of a trap are prohibited on ________.
Stall shower traps
72
Any part of a piping system that extends horizontally at an approved grade, with or without vertical extensions from the main to plumbing fixtures.
Branch
73
Any part of a drainage system that extends horizontally at a slope from a soil or waste stack, with or without lateral or vertical extensions, on two or more floors.
Horizontal branch
74
Satisfactory hanger which supports any piping must be
sufficient strength
75
When floor drainage is required for a cold storage room used for storing or holding food or drink, the drain must be connected to the sanitary drainage system through a
indirect waste
76
Who shall appoint the Board of Examiners for Master Plumber?
President of the Philippines
77
When provided with water outlets for such space, a 610 mm width of wash sink or 457 mm diameter of a circular basin, shall be _____.
considered equivalent to one lavatory
78
What is the urinal per male ratio for principal worship places?
1 per 150
79
A comprehensive term, including all constructions for collection, transportation, pumping, treatment and final disposition of sewage.
sewerage or sewerage works
80
________ is a device designed and installed to separate and retain deleterious, hazardous or undesirable matters from normal wastes and permits normal sewage or liquid wastes to discharge into the disposal terminal by gravity. a. Interceptor b. Clarifier c. Both a & b d. Grease trap
Both a & b
81
______ for “Sacrarium” cupsink at church altar and Baptistries font outlet shall discharge direct to the ground and not connected to the sanitary drainage system.
wastewater drain
82
What is the minimum thickness of copper pans or liners?
Gauge No. 24 B & S or 0.5 mm thick
83
What is the length of the pipe that should be added on the top of the highest fixture level to eliminate water hammer?
300 mm
84
The cover of the septic tank shall be at least ____ above the back- vent openings.
50.8 mm
85
The vertical distance from the “Grade Line” to the highest point of the coping of a flat roof or to the top line of a mansard roof or to the average height of the highest gable of a pitch or hip- roof.
Height of building
86
It refers to the pressure range measured over a period of 24 hours.
normal pressure
87
A water closet consisting of a continuous trough containing water. The trough extends under two or more adjacent seats. Prohibited by health authorities for permanent installations.
Latrine
88
What is the maximum interval of vertical supports for lead piping?
1.2 m
89
What is the water demand for shower head?
2.5 gpm
90
The lead shall be caulked thoroughly at the inside and outside edges of the joint. After caulking, the finished joint shall not extend more than ___ below the rim of the hub.
3.2mm
91
ln addition to the required incised marking, all hard-drawn copper tubing shall be marked by means of a continuous and indelibly colored stripe at least ___ in width.
6.4 mm
92
The minimum wall thickness of a steel septic tank that can be protected from corrosion internally and externally is
Ga. 12
93
What is the standard slope of the building drain?
2%
94
Rainwater piping located on the exterior of a building using galvanized sheet metal shall not be less than ______.
26 Ga
95
Two (2) walls opposite of differing heights - add _______ of wall area above top of lower wall to the roof area.
50%
96
A valve opened and closed by the fall and rise, respectively of an attached ball floating on the surface of the liquid.
Ball cock
97
A flushometer valve is a device used to
Discharge a predetermined quantity of water
98
The maximum height above the trap for a clothes washer standpipe receptor is ____.
0.80 m
99
Expansion joints shall be acceptable in piping, except
vents
100
A metallic sleeve, calked or join to opening in a pipe, into which a plug is screwed that can be removed for cleaning or examining the interior of the pipe.
ferrule