PLC's Flashcards

1
Q

What does PLC stand for?

A

Programable Logic Control

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What usually holds all the components of the PLC?

A

The rack

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What allows all of the components to be powered up?

A

The back plain

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How do the input, output and CPU all share information?

A

The back plain

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Where is the ladder diagram file stored in the PLC?

A

The CPU

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What part of the PLC executes all outputs and process input information?

A

The CPU

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

<Local1:I:Data)> Is this an input or output?

A

Input

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Is <Local1:I:Data)> discrete?

A

Yes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What terminal is <Local1:I:Data)>?

A

Zero

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

How do we program the PLC in lab?

A

A laptop

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What does the VFD start parameter need to be when using the Push Button program in lab?

A

3 wire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What does the VFD speed parameter need to be when using the push button program in the lab?

A

0 -10 volts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What do you need to do when changing the PLC program if you want to change the program that is in the PLC?

A

Download to the PLC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What do the VFD start and speed parameters need to be set to when using the PLC program that runs through the HMI?

A

Comport

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What brand is the compact logic controller?

A

Allen Bradley

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What enables the controller to interface with a pushbutton?

A

Input Module/ Card

17
Q

How many volts supply the PLC?

A

24 volts D.C

18
Q

How many volts does the communications voltage run on?

19
Q

What is the CPU responsible for?

A

Receiving Inputs
Controlling the outputs
Performing logical decisions according to the program

20
Q

What else is needed to make a basic system functional?

A

Mounting, Wiring, Programming

21
Q

What is the process variable?

A

It is the main point of the system that the set point is trying to maintain

22
Q

What is known as the EYE of the system that provides a feedback of signals of the controlled variable?

A

Measurement Device

23
Q

What is the set point?

A

The set point is the designated input value applied to the control loop

24
Q

In a control system what alters energy into a mechanical motion?

A

The Actuator

25
What does the controller do?
Receives error signals and feedback from the field devices or instruments in order to allow it to generate and output signal that will help maintain the set point
26
What compares the set point to the feedback signal and produces an output?
The Error Detector
27
What is the operation of actuators and a control system to maintain a controlled variable as its desired set point referred to as?
The manufacturing process
28
What is something that negatively effects a manufacturing process?
A disturbance
29
What could a pump in the manufacturing be considered if it is moving water through the lab station?
An actuator and/or muscle
30
What is the network identifier used in the lab for the automation equipment?
192.168.1.0
31
What is the subnet mask in lab?
255.255.255.0
32
What does IP strand for?
Internent protocol
33
What IP version do we use in the lab?
IPV4