phys depth 2 Flashcards
Main purpose
investigate the attentuation of ionising radiation of varying thickness of iron & lead, observing how the intensity of radiation changed
what is the advantage of semilog grid?
Using this enables the advantage of visualising the exponential relationship without the need to manually calc. the logs. It simplifies the plottimng & allows interp. to determine the att coefficient
explain the method
conducted with 137Cs source and the counter
1. measured bg count
2. measured the lead plate
3. measured the iron plate
calculated the natural log for only lead plates
significance
concluded that lead provided better source of shielding than iron
lead had higher att coeff & x value
higher attenuation means
greater ability to block out the xrays
Smaller x-value means
less material is needed to reduce the intensity by half
why was In chosen
because eqn 1 follows exponential decay - by taking log of both sides, we linearise the eqn to give us new eq. This allows us to determine the aatt coeff, providing a straight line.