If the beer is coming out of the tower warm what is a list of things that could be going wrong? What can you check?
A
We will re-run the btu load calculations to show this was sufficient . However, there are many things that can cause the higher temp. It is real tough to diagnose when a authorize Perlick installer didn’t install this.
- Has the electricity been verified
- Location of power pack. What is the ambient temperature there.
- Is the coolant connector lines insulated?
- Is there enough glycol in the system?
- What is the temp of the beer cooler?
- What is the temp of the beer in the kegs in the cooler?
- Where the towers installed properly with those connections with insulation?
- Are there any “hot” spots in the trunk line run from the cooler to the towers?