Oxygen Flashcards

You may prefer our related Brainscape-certified flashcards:
1
Q

For Smoke, how should the Oxygen Dilutor be set?

How long will it last?

At what Cabin Altitude?

A

Use 100% oxygen

Good for flight crew and observers for 15 mins

Cabin Altitude of 8,000ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

During a cruise of FL100, how long will the oxygen last for 2 flight crew of two?

A

107 mins

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

During an Emergency Descent, what setting should the Oxygen Dilutor be set to?

How long will the oxygen last for flight crew and observers?

A

Set the Oxygen Dilutor to N to save oxygen. (A mix of oxygen and cabin air)

13 mins

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

If the crew member is bearded, can this affect the oxygen time?

A

Yes. It may be shorter based on mask seal on face

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

When is the OXY pressure indication on the SD Door/Oxy page green?

A

At or above 800 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When is the OXY pressure indication on the SD Door/OXY page “pulsing” green?

A

Below 800 psi and the SD Door/OXY page is automatically displayed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

When is the OXY pressure indication on the SD Door/OXY page amber?

A

Below 400 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When does the amber half frame appear on the SD Door/OXY page?

A

Below 1,500 psi and on the ground

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

When does the amber OXY appear on the SD Door/OXY page?

A

When the Oxygen Crew Supply pb on the Oxygen panel is switched off

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

When does the amber REGULAR LO PR on the SD Door/OXY page appear?

A

When a low pressure is detected in the circuit to the mask

How well did you know this?
1
Not at all
2
3
4
5
Perfectly