Overview (My Observations) Flashcards
The Medium Pressure Loop contains gas from what sources?
Bayfield Dry Creek Miera Pinon Dead Horse (Red Cedar)
ECBM contains gas from what sources?
Salvador
Tiffany
Iron Horse
Horther
Area 6 contains gas from what sources?
Wolf Point
Williams (Unusual)
Area 1 East contains gas from what sources?
Klusman
8”
10”
Area 1 West contains gas from what sources?
Old 12”
New 16”
What header does the Medium Pressure Loop enter?
Booster Suction Header
What header does the ECBM enter?
Amine Header
What header does Area 6 enter?
Amine Header
What header does Area 1 East enter?
Low Pressure Header
What header does Area 1 West enter?
Low Pressure Header
What compressors are fed by the Low Pressure Header?
#1 Howden #2 Howden Old Ocean (Field Compressor 3) JM-4 (Field Compressor 4)
At what pressure does the Amine header go to the flare?
345
At what pressure does the Booster Suction header go to the flare?
305
At what pressure does the Tailgate Sales header go to the flare?
805
At what pressure does the Low Pressure header go to the flare?
60
What are the sales outlets?
Northwest
Transwestern
El Paso (Rarely)
What are the alarm points for sales CO2?
- 0% - Alarm
- 1% - 12 minutes until shut in
- 0% - Immediate shut in
What are the alarm points for sales H2O?
- 0# - Alarm
- 1# - 60 minutes until shut in
- 0# - 2 minutes until shut in
What are the alarm points for sales temperature?
120F - Alarm
121F - 60 minutes to notify a field tech to verify temperatue.
130F - Immediate shut in
What is the flow rate of the Medium Pressure loop?
Around 145 mmscfd
What is the flow rate of the Bayfield Plant?
Around 55 mmscfd
mcf means?
1000 cubic foot
mmscfd means?
1 million standard cubic foot per day
What is the flow rate of Dry Creek?
26 mmscfd
What is the flow rate of Miera?
35 mmscfd
What is the flow rate of Pinon?
21 mmscfd
What is the flow rate of Dead Horse?
7 mmscfd
What is the flow rate of the ECBM line?
80 mmscfd . Around 30 goes to FRCF.
50 mmscfd goes to Red Cedar.
What is the flow rate of Salvador?
30 mmscfd
What is the flow rate of Tiffany?
6 mmscfd
What is the flow rate of Iron Horse?
40 mmscfd
What is the flow rate of the Horther?
3.5 mmscfd
What is the flow rate of Wolf Point?
28 mmscfd
What is the flow rate of Area 1 East and Area 1 West?
66 mmscfd
What compressors are fed by the Booster Suction Header.
Electric 1 Electric 2 Electric 3 #1 Turbine #2 Turbine
What is special about the Horther well?
It has enough pressure to enter the ECBM line.
Which Boost compressor is the largest?
Boost 3
15,000 HP
190 mmscfd
What is the plant flow rate?
Around 270 mmscfd
What is the psi of the Low Pressure Header?
42
What is the approximate psi of the Amine Header?
300
What is the approximate psi of the Dehy Header?
276
What is the approximate psi of the Booster Suction Header?
270
What is the approximate psi of the Tailgate Sales Header?
710
What is the approximate psi of the Bayfield Suction Header?
27
What is the approximate psi of Bayfield’s discharge?
305
The Central Facility Flare Knockout Drum discharges water to?
The Oily Water Storage Tank located south of the Amine building.