Overhead Panel Flashcards
Prep for Oral Exam
What does the DC service switch power?
- Lights (Nav, Beacon, Service, Boarding, Galley Dome, Lavatory.
- Boarding Announcement
- Chart Lights
- Cabin Lights, Upward and Downward
- Service Bus
- Power Sensing (Service Bus and TRUs)
- Waste and Water Control
What lights illuminate with the Battery Master ON
(no AC power established)
- AC ESS XFER switchlight
- The INOP portion of the L & R boost pump switch lights
- The FAULT portion of the PRESS CONT switchlight
- The OFF portion of the L & R PACK switch light
- MACH TRIM switch light
Regarding the AC switchlight, what does the illumination of the AVAIL portion
indicate?
The system has the correct
- Voltage (115 v)
- Frequency (400 hz)
- Phase (3 phase)
Regarding the IDG guarded switchlight, what does the illumination of the FAULT portion indicate?
DISC portion?
- Associated IDG has either high oil temp (HOT) or low oil pressure (LOP). (HOT-LOP)
- The DISC portion indicates that the associated IDG has been disconnected.
What does illumination of the AC ESS XFER switchlight indicate?
AC BUS 1 is not powering the AC ESS BUS.
When should the generator be reset?
When directed by the QRH
(ex: QRH ELEC 12)
Regarding the AUTO XFER switchlight, what does illumination of the FAIL portion indicate?
- The associated GCU (Generator Control Unit) has detected a BUS fault or generator overcurrent.
- The affected generator is taken offline.
- The GCU inhibits the auto transfer system on the affected side.
- Associated AC BUS can no longer be powered by the APU or offside.
What is associated with a successful fire test?
- FIRE SYS OK advisory message
- LH ENG, RH ENG, and APU FIRE PUSH switchlight illuminate.
- LH, RH and APU BOTTLE ARMED PUSH TO DISCHARGE switchlight illuminate.
- Both Master Warning Flashers illuminate.
- FWD & AFT CARGO SMOKE PUSH switchlights illuminate.
- Cargo BOTTLE ARMED PUSH TO DISCHARGE switchlight illuminates.
What is the function of the L/R HYD SOV guarded switchlight?
To interrupt the flow of hydraulic fluid to the associated EDP (Engine Driven Pump).
Regarding the L or R Boost Pump, what does the INOP portion of the switchlight indicate?
The ON portion?
- The pump outlet PSI is too low (INOP)
- The pump outlet PSI is satisfactory (ON)
What does the FAIL portion of the GRAVITY XFLOW switchlight indicate?
The gravity crossflow valve is not in the commanded position.
Regarding the L or R XFLOW switchlights,
what does the FAIL portion of the switchlight indicate?
The ON portion?
- Respective crossflow SOV is not in the commanded position or crossflow pump failed to energize with L or R crossflow SOV selected open.
- ON crossflow pump energized, fuel directed into low tank.
Explain the function of the XFLOW AUTO OVERRIDE switchlight.
Pressed IN
Pressed OUT
- Pressed IN arms the crossflow pump for manual crossflow and inhibits the auto crossflow function. (switch is illuminated).
- Pressed OUT crossflow pump is disarmed for manual use and auto crossflow is available. (switch not illuminated)
Tell me about the
WING A/I CROSS BLEED rotary switch.
- FROM LEFT: the right wing anti-icing valve is closed and the crossbleed valve opens to permit bleed air from the left engine to provide anti-icing to both wings.
- FROM RIGHT: the left wing anti-icing valve is closed and the crossbleed valve opens to permit bleed air from the right engine to provide anti-icing to both wings.
Tell me about the
BLEED VALVES rotary switch
- AUTO allows for automatic operation of the bleed valves.
- CLSD selects the valves to the closed position.
- MANUAL allows for manual open or closed operation of the valve (controlled by the ACSC).
4.