Other Memory Items Not Required Flashcards
1
Q
APU start cycle
A
3% (0%airborne) ignition energized
& Main Fuel Solenoid Valve opens
50% Starter de-energized
70% Ignition Exciter de-energized
95% + 7 sec: MAX fuel solenoid valve energized
Pneumatic & Electrical pwr available
If no EGT rise then 1 AUTO restart (swing start):
Starter de-energized @ 20% & Re-energized @ 5%
2
Q
Power plant Ignition settings
A
OFF - de-energizes ignition system
AUTO - active FADECs control ignition system automatically
- one channel for ground start (14% N2) - both channels for air start. (10% N2) - Auto relight. (Above 53 % N2)
ON - commands FADEC to continuously activate both ignition channels; A & B
- 1st flight of day - cold engine starts SAT or oil < or equal 5 degrees C - External air or crossbleed start - Contaminated runway TO and < equal 10 C - Moderate or > turbulence or heavy precip
3
Q
APU control MASTER
A
OFF - de-energizes FADEC