Original Deck Flashcards

1
Q

Mourning Band Protocol

A

Worn straight across the center of the badge A, B or C uniform

Width of the black band should not exceed ½ inch.

Worn for a period of 30 days from the date of a CFD LODD

Optionally worn for the LODD of a neighboring jurisdiction from the date of death and removed at the conclusion of the day of burial.

GO 18-012 ❗️

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How many masks are needed during a deep tunnel incident?

A

6 (5 plus one extra)

GO 92-005 ❗️

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

In the City of Chicago, Standpipe Outlets come in three types:
CLASS I
CLASS II
CLASS III

A

Class I, with a single 2 ½ inch male connection.

Class II, with a single 1 ½ inch male connection. This type of system is not utilized by the CFD.

Class III, with both 2 ½ inch and 1 ½ inch male connections. This is the most common type of Standpipe Outlet found in Chicago.

SOP 210.00

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

CFD Forms Review:

A
160 - Report of Injury or Illness (layup)
159 - Return to Duty
919 - House Repair
11.202 - Damaged Hose
11.203 - Lost or Stolen Equipment
920 - Bereavement Leave 
PER 72 - Address Change
903 - Allegation of Violations
156 - Hose Test 
FORM 4 - Hydrant Inspection

Form Manual

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

During CO investigations, when do you notify the gas company? 4 answers

A
  1. Levels greater than 9ppm
  2. Any appliance turned off
  3. Occupants show signs of CO poisoning
  4. IC requests

SOP 507.07

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

During a stalled train, if it is determined that service will be interrupted for more than 10 minutes, sufficient life safety hazard exists to enter the train or passengers are beginning to self evacuate, what 4 actions shall be taken?

A
  1. Locate entry point( s) and approximate location( s) of train( s ).
  2. Request a power shutdown of the system.
  3. If informed that the power has been shutdown by CTA, request a secondary hold.
  4. Deploy the following personnel and equipment
    a. Truck officer with hand-light and bullhorn (from Battalion Chief).
    b. A member of the truck with forcible entry tools and hand-lights.
    c. 2 Members from Engine with hand-light and portable oxygen.
    d. 2 Ambulance Paramedics with QRB, portable oxygen, Lifepak 12 and stairchair.

OO 08-003

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

In a high rise fire, who is located 1 floor below the fire floor?

A

The 1st Engine (FIT engine connecting to standpipe for leadout 50, 60 70psi)

2nd Engine assisting the 1st engine

RIT staging (1bc, 1truck, 1 ALS engine - ALS ambo in lobby)

SOP 210.00

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

How is the transport index measured for radioactive material?

A

The TI is measured in mR/hr at one (1) meter (3.3 feet) from the surface of the package.

SOP 511.00

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Elevator rescue ladder should extend how many feet above the opening in the car?

A

3 feet

Elevator Manual

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Supervac V18 Fan Specs

A

Used for positive pressure only

Will operate for 30mins with 2 full batteries

Batteries must be above 40’ to charge and will fully recharge in 90mins.

OO 20-019

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q
What do the following stand for in a Radiation Response with intentional devices:
RDD
RED
RID
IND
A

RDD-Radiological Dispersal Device (dirty bomb, wide area)

RED-Radiological Exposure Device (source usually hidden, intended for specific person)

RID-Radiological Incendiary Device (couples fire with radio active material)

IND-Improvised Nuclear Device (high levels, large area)

SOP 511.00

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

All vehicle types require a minimum of how many hours of drivers training.

A

12 hrs.

Members seeking cert must have completed 12 months in the field since academy graduation.

GO 20-006

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Who does the FIT Engine notify of the adequacy of water supply from the standpipe connection?

A

Fire Attack Chief

If more than 200 feet of hose is needed, notify Lobby Command

CFD members are prohibited from using CFD 1 ¾-inch hose, or 1 ½- inch “house” hose lines for a high-rise fire attack.

SOP 210.00

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

DURING HIS TOUR OF DUTY Engineer CREEDON TELLS LT LINK HE IS VERY TIRED AND WOULD LIKE TO TAKE A NAP AFTER MORNING CHORES. DURING WHAT TIMES IS IT NOT PERMISSIBLE TO SLEEP OR LOUNGE AROUND COMPANY QUARTERS?

A

0700-1800HRS

GO 13-007

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

At approximately how many minutes of heavy fire on 2 or more floors will an ordinary constructed building become structurally unsafe?

A

After 20 minutes

QD Jan 2002

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What are the approved visiting hours, including times for Union Reps and non-platoon duty?

A

0930-2100

Union Reps - 1200-1300 and 1600-2100, or 30 mins after roll call for non platoon duty

GO 00-003

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q
In a high rise: what is the engine and truck response on:
Automatic Alarm in Category 2, 3, or 4?
Automatic Alarm in Category 1?
Still In a High Rise?
Still and Box in a High Rise?
A

Automatic Alarm in Category 2, 3, or 4? 1E, 1T, 1BC

Automatic Alarm in Category 1? 2E, 2T, 1BC

Still In a High Rise? 3E, 2T, 3BC, 1SQ, 1A, 1PFC, 1CV, 1DDC

Still and Box in a High Rise? 6E (including 1 ALS engine), 4T, 1 TL not used as RAT, ect.

SOP 210.00

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Non-pressurized Ansul extinguishers must be inspected annually and hydrostatically tested every how many years?

A

12 years

LO 15-003

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

During a progress report, what does C.A.N. stand for?

A

C-onditions
A-ctions
N-eeds
SOP 111.00

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

After how many hours will undistributed checks be returned to district?

A

72 hours

GO 92-016

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Who approves HEMS activation?

A

Assistant Deputy Chief Paramedic

SOP 408.00

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

LT WOLF OBSERVES SEVERAL DOWNED POWER LINES WHAT IS THE MINIMUM AMOUNT OF SPANS HE SHOULD ISOLATE ?

A

A MINIMUM OF 1 SPAN

S.O.P. 203

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Is the TIC camera intrinsically safe?

A

NO.

QD April 2004

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

If HEMS requested at Hazmat, the LZ should be located at least what distance away?

A

1 mile

SOP 408.00

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
In addition to the Drill of the Day, Company Officers must conduct at least ____ other Company Drills and/or Company Schools during each tour of duty.
At least 2 (for a total of 3) must be entered into sharepoint by 2100 1hr hands on 1hr classroom OO 15-002 ❗️
26
When shall target hazards pre-plan inspections be done?
On a monthly basis, identify 1 facility, occupied or vacant, in their respective still district. GO 07-014 ❗️
27
What defines a "master stream"?
A high-volume (minimum of 350 gallons per minute) stream delivered through a minimum 1 ¼-inch nozzle. SOP 207.00
28
DURING SIZE UP LT. LINK NOTICES HEAVY FIRE FROM CHIMNEY, CRACKS IN FOUNDATION, AND FILLING FIRST FLOOR DOORWAY. WHAT IS THE MOST LIKELY LOCATION OF THE FIRE?
THE BASEMENT A basement is defined as a story of a building partly or wholly below grade in Side A per Multi-Co Ops 14-001 AN SUMMER 2004
29
What is the preferred method for shutting off the electricity during a fire to preserve evidence?
Shut off the main breaker Multi Co Ops 11-003 AN Spring 2008
30
When a funeral is out of state and beyond the contiguous states, how many days is an employee entitled to?
Max of 5 consecutive calendar days, for platoon employees shall include no more than 1 working day KIWI MM - Kentucky, Iowa, Wisconsin, Indiana, Missouri, Michigan Contract ❗️
31
Immediate Family Members are:
The immediate family is defined as the employee's spouse, parents, children (including step and half), brother, sister, father-in-law, son-in-law, mother-in-law, daughter-in-law, grandparents, grandchildren and domestic partners. GO 95-007
32
On the Standard Hydrant Wrench there are 4 operating keys. What does each do?
1. Large pentagon - hydrants/hydrant caps(use quarter) 2. Large square - Dept of Water underground valves 3. Small pentagon - buffalo boxes 4. Small square - CTA sidewalk access, wall hydrants and hydrant missing opertaing nut(use nickel) SOP 204.00
33
Which 2 dangerous buildings have the potential for fast fire spread and/or imminent collapse likely due to flame impingent on exposed structural members?
1. Building under construction 2. Building under renovations. SOP 262.00
34
Who does the FIT Truck report initial size up and conditions to in a high rise fire?
Lobby Command **Including any conditions on the way up** SOP 210.00
35
On a 45 minute bottle, the primary low pressure device bell rings when there is approximately ___ % of the SCBA’s rated service time remaining?
35% - and activates RIT light on UAC On a 45min bottle, the bell begins ringing with approximately 16 minutes of useable air, or 1575 psi, remaining. Bell continues to ring until air pressure 200 psi or less G-1 MSA-SCBA Manual ❗️
36
Any member working in or near a collapse zone without an SCBA must utilize what?
A stand alone pass alarm SOP 209.00
37
WHAT IS THE MAXIMUM ALLOWABLE TIME A COMPANY CAN WORK AT A FIRE BEFORE THE COMPANY MUST REPORT TO THE REHAB AREA ?
45 MIN. S.O.P. 107
38
What is the explosive range of CO (carbon monoxide)?
12.5% to 74% CO @ a temp of 1200'F with oxygen will explode. CO slightly lighter than air TB 1987-04 ❗️
39
For a Blast Incident, what is the Blast Hot Zone?
For a high-rise, Blast Hot Zone shall be three (3) floors above and two (2) floors below the area affected by the blast. For below grade the Blast Hot Zone shall include the tunnel area or basement area affected by the blast up to street level. SOP 509.00
40
What are some indicators of a basement fire?
1. Heavy smoke from chimney 2. Smoke coming from foundation cracks and mortar joints 3. Smoke coming from attic, esp. balloon frame 4. Discoloration or melting of vinyl siding near foundation 5. Smoke from vents or baseboards of 1st floor 6. Smoke filling 1st floor doorway 7. Heat and smoke on 1st floor without fire 8. Elevated temps on TIC thru basement windows Multi Company OPS 14-001
41
What are the 5 steps in Structured Risk Management Assessment?
1. IDENTIFY risk exposure 2. EVALUATE risk potential 3. RANK and PRIORITIZE risks 4. DETERMINE and IMPLEMENT actions 5. EVALUATE and REVISE actions SOP 101.00
42
Upon receiving a career service promotion or being appointed to an exempt rank, can a drug test be administered?
Yes GO 87-008
43
How are hard and soft suction hoses tested?
Static hydrant pressure GO 93-012
44
All Business, Mercantile, Industrial and Storage Occupancies exceeding 4000 square feet shall have not less than how many exits?
No less that 2, no less than 36" wide, with the travel distance to the exit not to exceed 150ft unless building sprinklered. This distance shall be increased by 50% if building is sprinklered. In a hazardous industrial building travel distance to an exit can not exceed 75 feet regardless of sprinkler system Overhead doors not considered a means of egress TB 1989 Fall and 1991-05 ❗️
45
What makes up the CFD Response Team at ASI/ATI?
At least 4 members (consist of the Company Officer and a minimum of three other members from the same company) SOP 602.00
46
After how days of separation from the department can a drug test be administered?
In excess of 30 days GO 87-008
47
Who is responsible for entering the run in the journal when a company is relieved on the scene of a fire?
The off going officer GO 92-009
48
What are the 3 Out of Service Categories?
1. Equipment OOS 2. Mechanical OOS 3.Administrative OOS - Unfit for duty, Accident (etoh test),Medical treatment,deconof equip/personal **Special Duty is not OOS, but is NOT ordinarily available for emergency responses by orders of a Chief ie. training, court, IAD) GO 14-002
49
List the 4 stages of fire?
1. Incipient 2. Free burning 3. Open free burning 4. Smoldering TB 1987-04 ❗️
50
What is issued to every engine that lists specific locations of water mains that are 16 inches or greater?
CFD Atlas of Water Mains SOP 290.00
51
EES systems - vehicles must not be run for more than ___ at a time to prevent damage?
3 minutes OO 14-012
52
How should you clean SCBA facepiece?
Submerge in cleaning solution for a minimum of 30 seconds, water temp 110 degrees G-1 MSA-SCBA Manual ❗️
53
WHICH OF THE FOLLOWING WOULD BE AN APPROPRIATE METHOD FOR EFFICIENTLY DRAINING WATER FROM AN UPPER FLOOR?
USE A HALLIGAN TO LIFT THE TOILET AND EXPOSE THE DRAIN AN JAN 2000
54
Who does the EMS Staging Officer (designated by EMS Command) report to on EMS Plans?
Report directly to EMS Incident Command at an EMS Plan 1 Report to the EMS Plans Chief at an EMS Response Plan 2 or greater SOP 401.00
55
Who conducts systematic review of structure during dangerous building fires/defensive operations?
Battalion Chief, Safety Chief, RIT Chief and RIT Officer ***In OO 13-008 it states IC, RIT Chief, RIT Officer, and Company Officers involved in interior attack** SOP 262.00
56
CO has a vapor density of what?
.968 - slightly lighter than air SOP 507.07
57
IT IS FEB 21, BREEZY 28 DEGREES AND SNOW IS EXPECTED LT ZEIGLER ASKS ENGINEER MUMBLES AT WHAT LEVEL SHOULD THE FUEL BE MAINTAINED DURING THIS TIME?
5/8 FULL OO 18-020
58
What are the dimensions of the LZ?
Minimum of 100x100 feet Must also have 50 feet safety perimeter Level (less than 5 degrees gradient) and firm ground SOP 408.00
59
According to dispatch protocol, for all responses to a structure with a Red "X" placard, the 1st arriving company officer shall communicate arrival info including what 3 things?
1. The presence of a First Responder Warning (RED X) Placard. 2. Any obvious structural deficiencies 3. A request for verification that an additional Battalion Chief has been dispatched to act as the Safety Chief. OO 13-008
60
When responding to a vehicle fire, what is the minimum amount of feet that the first arriving engine or truck should position itself away from the vehicle?
100 feet QD July 2004
61
In the journal, what 3 places must list the complete date and time?
At the 0001 mark, the top over every page, and at Roll Call GO 13-017
62
On an EMS Plan 1, who functions as the triage team?
The 1st arriving Ambo and the 1st arriving FS and R company. SOP 401.00
63
SCSCVEOS??
``` Size up Call for help Save Lives Confinement Ventilation and forcible Entry Extinguishment Overhaul Salvage ``` AN APR 2000 (size up)
64
IF A FIRE HAS EXTENDED TO THE ATTIC AREA AND A SEARCH FOR A VICTIM IS REQUIRED WHAT SHOULD SEARCH TEAM HAVE WITH THEM FOR THEIR SAFETY?
A CHARGED LINE Q.D. JUNE 2001
65
Who is responsible for determining fit for duty status?
2 supervisors 1 being of exempt rank GO 87-008
66
Where is RIT staging normally located at a non high rise fire?
Side A SOP 106.00
67
When is the fuel truck automatically dispatched?
3-11 alarms or higher GO 19-001
68
What info is entered in the journal on a daily basis until the handpunch is repaired?
Date/time discovered inoperable Repair ticket# Any work performed and outcome of work Under the direction of the BC, members required to swipe at FH in district until repaired After 7 days Captain contacts Logistics, BAS to inquire GO 19-004
69
When dispatched on a change quarters, what do you press on the PDT?
CQE not ENR OO 13-012
70
How many days suspension do you get for physical violence/fighting?
9 day minimum non emergency scene 15 day minimum on emergency scene GO 00-001
71
Where is rehab established at a high rise fire?
In the lobby (or adjacent structure if necessary) SOP 210.00
72
How far below the water surface can the TIC recognize a heat signature?
It cannot recognize heat signatures 1/8” below the surface of the water. QD April 2004
73
IF BC ARRIVES ON SCENE OF A STILL BEFORE STILL ENGINE WHAT INFORMATION SHOULD STILL ENGINE REPORT?
UNIT # ON SCENE DIRECTION OF TRAVEL QD NOV 2003
74
How do you check the battery status on G-1 MSA-SCBA?
By holding down both reset buttons. Battery icon will auto shut off after 10 seconds G-1 MSA-SCBA Manual ❗️
75
A "Blue Slip" expires how many days after issuance.
30 days GO 20-006
76
Oxygen cylinders and pressurized air cylinders shall be hydrostatically tested every how many years?
5 years LO 15-002 ❗️
77
If a radio call is not acknowledged, within how many seconds should you repeat the call attempt from the same radio no more than 3 times before switching to another radio?
15 seconds Try 3 times more from new radio. If no response, switch to another OEMC frequency GO 12-008
78
During cold weather, If the air dryer is not working properly tanks must be bled manually twice daily. What times
0800 and 2000 OO 18-020
79
Personal Protective Clothing (PPC) in-station biological disinfecting and routine cleaning procedures:
Spot treat by applying in-station disinfectant (Conquer TBQ), wet thoroughly , wait 10 minutes and rinse with clear water. If using warm water do not exceed 105'. Do not use brushes on liner OO 07-009
80
What are the steps in donning G-1 MSA-SCBA?
``` RT Arm LT Arm Waist Belt Chest Strap Adjust Shoulder Straps Adjust Lumbar Tuck In Waist and Shoulder Straps ``` *When removing, Left arm comes out first* G-1 MSA-SCBA Manual ❗️
81
At what percentage of the LEL will the high level alarm sound and at what percentage will the low level alarm sound on the multi gas monitor?
High - greater or equal to 25% Low - greater or equal to 10% SOP 507.08
82
With the exception of Hazardous Use Occupancies, fire extinguishers are not required in business, mercantile, industrial, and storage units under _____ square feet?
3000 If required, must be visible from a distance of 50ft Travel distance to shall not exceed 75ft AN Fall 2004
83
In a mayday situation, who shall remain on the original tactical channel, which shall become the RIT channel:
1. Member who declared the mayday 2. Company of the member who declared the mayday 3. Company with distressed member if different than the company who declared 4. The RIT SOP 102.00
84
Porch landing shall not exceed _____ sq. feet or project more than _____ feet out from the building?
Not exceed 150 sq. feet Not project more than 10 feet out from the building FPBI
85
When the fire is in the basement or lower levels of a high-rise, Lobby Command, Forward Fire Command, and Search and Rescue Command posts, as well as the Rehab Area, will be set up where?
On the exterior near the entrance(s) of the structure. SOP 210.00
86
What are Guide 112 and Guide 114 used for?
Guide 112 is used for an explosive except for 1.4 and 1.6 Guide 114 is used for explosives 1.4 and 1.6 Multi Company Ops 20-005
87
On and EMS Plan I, the Officer of the 1st arriving _____ Company shall be responsible for all incident EMS communications until the establishment of Incident Command.
Ambulance SOP 401.00
88
If an apparatus has not been towed, after how many hours should the officer notify District Headquarters via chain of command?
2 hours SD 08-001
89
WHO SHOULD ASSUME CONTROL OF OVERHEAD DOOR WHEN BACKING INTO FIREHOUSE WHEN ANOTHER COMPANY IS IN QUARTERS WHILE BACKING IN?
A MEMBER FROM THE COMPANY BACKING IN SD 97-001 SOP 702.00
90
What are the 4 types of blast injuries?
1. Primary - direct blast injury (blast wave) 2. Secondary - caused by flying objects- more common than primary and the most common cause of death 3. Tertiary - victim being thrown 4. Miscellaneous - includes burns, crush injuries, dust inhalation, and CO poisoning Secondary device timed to explode 30 to 100 minutes after the first device has detonated. This second device is designed to injure EMS, fire, and police personnel who may be at the scene. AN Summer 2004
91
Where are machine rooms located for the 2 types of elevators? Electric Traction Elevator Hydraulic or Piston Elevator
1. Electric Traction Elevator: top or bottom of shaft, or 2 floors above highest floor serviced by elevator. This is the most common type of elevator. 2. Hydraulic or Piston Elevator: machine room along side of car or lowest landing serviced by elevator Elevators are 480 volts Elevator Manual
92
During rehab, a member may return to work when vitals are?
1. Pulse rate below 110 bpm 2. Typanic (ear) temp is above 95' and below 100.6' SOP 107.00
93
IT IS 0800 *MONDAY* JULY 6th. LT LINK CONDUCTS ROLL CALL ACCORDING TO REGULATIONS WHAT MUST LT LINK INSURE IS DONE THIS MORNING?
RIT PACK AND TRANSFILL HOSE SHALL BE CONNECTED AND TESTED. G.O. 17-018
94
What are the dimensions of the approach corridor for HEMS?
The air space extending up a max of 300 feet and downwind from the LZ a max of 250 feet that is used for the helicopter approach. For every 100 feet of altitude there needs to be 50 feet of Approach Corridor. SOP 408.00
95
WHEN ON AN AMBULANCE ASSIST RUN AND PT CARE IS COMPLETED, FROM WHERE SHOULD LT DUPONT REPLACE EXCHANGEABLE EMS SUPPLIES USED FOR THIS PT?
FROM AMBULANCE COMPANY TRANSPORTING PATIENT. OO 17-011
96
Collapse Zones Summary
When operating on ground level, the Vertical Collapse Zone shall be at least 2 times the height of the wall; when operating an Elevated Master Stream the Vertical Collapse Zone shall be at least the height of the wall above the elevated platform. The Horizontal Collapse Zone shall be at least the entire length of the wall. CONTRADICTED by AN spring 2004 ( states vertical collapse zone 1 1/2 x height) SOP 207.00
97
What should you do if you become exhausted or are close to losing consciousness?
Turn on PASS alarm Turn on flashlight Lay horizontal facing up along exterior wall, doorway, or hallway Shine light at ceiling Multi-Co Ops 13-006
98
If smoke and/or water are encountered in the hoistway or elevator car while members are using the elevator, they must stop and exit the elevator at the nearest available floor and notify who?
Lobby Command SOP 210.00
99
At what times shall officers conduct scheduled inspections of company quarters?
0830, 1630, 2200, and 0230 GO 98-004 GO 98-003
100
Buildings that are ___ or more stories in height that have stairwell locking systems that would prevent reentry on a floor must have stairwell enclosure doors that are equipped with a fail-safe electronic lock release system that is activated both manually by a single switch located on the FACP or automatically.
5 AN Summer 2009 (Fire alarm systems)
101
Compare the cylinder gauge to the control module to ensue there is no more than ____ psi difference?
225 psi (within a 5% range) The digital gauge measures in 5psi increments G-1 MSA-SCBA Manual ❗️
102
The CFD will initially contact a distressed boat on what channel, then instruct the boat to change to Marine 11 for direct communications?
Marine 16 Use Lakefront 14 to contact Park District Lifeguards SOP 508.00
103
When are In-line operations used for elevated master streams? 3 answers to be complete
1. The Engine supplying the elevated master stream is more than 100 feet from a hydrant 2. The Engine is more than 100 feet from an elevated master stream 3. If the high-pressure pumper is more than 150 feet away from the Fire Department Connection SOP 290.00
104
What might be a priority for the 1st Truck arriving to a Blitz attack?
Laddering an exposure building SOP 263.00
105
What is the sequence when donning structural firefighter gear?
1. Bunker pants 2. Boots 3. Suspenders 4. Hood 5. Coat 6. Helmet 7. Gloves Wearing of suspenders is mandatory with bunker pants PPE Inspection TUESDAYS GO 16-004
106
What is the minimum length pike pole for roof ventilation?
10ft QD August 2003
107
``` What activities do you initiate based on the following dose? 0R to 5R 5R but less than 10R 10R but less than 25R 25R but less than 100R ```
Up to 5R - necessary tasks, no restrictions Up to 10R - evacuations and searches, search and rescue and protection of valuable property Up to 25R - rescue known/suspected viable victims, search and rescue only Up to 100R - volunteer only, ok'd by IC, briefed on risks to rescue known victims, enter entry is restricted SOP 511.00
108
The sections of the Code of Professional Conduct, Rules and Regulations, Practices and Procedures allegedly violated shall be listed on the Form #903. True or False
False GO 18-009
109
Flammable Liquid Storage Table
Frame | All Other Class I 5 10 1gal con. Class II 5 10 1gal con. Class II 5 60 5-60 gal con. Class III 60 120 All Excess of 10 gallons but less than 50 gallons must be stored in an approved storage cabinet. Max of 50 gallons per storage cabinet. Portable containers 10 gallons or less for Class 1 must have Spark Arrester AN Spring 2008
110
In approximately how many seconds will the pressure between the SCBA cylinder and RIT SCBA cylinder equalize?
30 to 60 seconds To relieve pressure in the trans-fill hose, replace the rubber cap on the female fitting. Then push the center of the rubber dust cap against a hard surface. Multi Company OPS 07-001
111
What is the effective method for pressurizing a high rise stair well with a PPV fan?
Multiple fans 1 fan at the base of the stairwell 1 fan every 10 floors 1 fan 4 floors below the fire floor Truck OPS 13-001
112
Where should you position the apparatus during a radiological event?
Outside initial background X3 Position or reposition the apparatus outside any areas with elevated readings (initial background times three) SOP 511.00
113
A deckgun can reach how many floors when properly supplied?
15 floors SOP 210.00
114
When dealing with an unattended package, when would the Engine Company officer request a Level I Hazmat along with a suspicious package response?
When the unattended package is determined to be a Suspicious Device by CPD. SOP 510.00
115
Water that is _____ degrees or below is treated as ice diving?
45 degrees Standard shape of the hole cut in the ice is a triangle with tightly angled corners for efficient exit Multi-Co Ops 18-003
116
What is stored in the back pocket of the search rope?
A 25ft piece of 1-inch webbing Multi Company OPS 08-002
117
Do not use G-1 MSA-SCBA if pressure drops more than ___ psi in 10 seconds on the digital gauge.
100psi G-1 MSA-SCBA Manual ❗️
118
Snow accumulation above 1 inch is the responsibility of the off-going shift up to what time?
Anytime before 730 SD 93-002
119
The first attempt towards gaining access into a structure secured with DAWGS should begin at the _____
Rear door Truck OPS 11-004
120
What are 5 classes of Fire Doors?
INTERIOR DOORS Class A - 3hr rating, no glass, used for protection of firewalls Class B - 1 1/2hr rating, 100 square inches of wired glass, used for protection of vertical shaft Class C - 3/4hr rating, panels of standard wired glass not to exceed 1296 square inches, used for protection between room and corridors EXTERIOR DOORS Class D - 1 1/2hr rating, no glass, used for protection in openings of exterior walls Class E - 3/4hr rating, 720 square inches of wired glass,used for protection in openings of exterior walls AN Sept 2004
121
When are the chiefs & company stand alone PASS alarms tested?
Fridays (At 0800 roll call) (BC 8, TRK & TL 2,SQD & HAZ 6) OO 18-001
122
What are the specifications of labeling hose?
On opposite sides at each end: White back ground 12inchs long 8inchs from the butt Length number black 1 1/2 to 2inches high CO # to the right of length number in red 2 inches high GO 93-012
123
Where are subway vent fans and vent shafts placed?
Every 450 feet CTA Manual
124
If unsure what type of fire, what foam should you use?
Start with 6% and only downgrade to 3% if it is discovered that the product is a pure hydrocarbon 3% - hydrocarbons - dark smoke 6% - polar solvents - light smoke (six looks like upside down P) Engine Co Ops 21-001
125
Approximately how many minutes after exposure to fire will unprotected wood floors collapse?
Less than 10 minutes Multi Company OPS 14-001 (Basement fires )
126
A high-rise building standpipe is required to reach how many floors below the top floor?
2 floors SB 09-002
127
What are the requirements to receive at least 20 minutes of rehab during an emergency scene?
45min of strenuous activity (physical) 30mins in Hazmat suit A, B, or C 30mins of additional work following a previous rehab If member fails vital requirements following 2 rehabs, request an ALS ambo SOP 107.00
128
FMLA, CDF will provide to eligible employees how many weeks of job protected leave within a 12 month period? And how many weeks of military caregiver leave?
12 weeks and 26 weeks military Eligibility requirements: Employee for at least 12 months, does not need to be consecutive but must have occurred in the last 7 years. Must have worked at least 1,250 hours in the previous 12 month period 5 days to be notified of eligibility 15 days to submit medical certification GO 17-008
129
When is the RIT pack and rescue hose tested?
Mondays GO 17-018
130
How long should you monitor a radio channel to be sure it is clear before speaking? Ensure microphone is how many inches away from mouth or SCBA voice port?
3 seconds 1 to 2 inches (Speak directly into grill of mic) GO 12-008
131
Carbon-wrapped cylinders must be tested every how many years?
5 years G-1 MSA-SCBA Manual ❗️
132
Fire Extinguishers: What are the 5 classes and specs of each?
Class A - Green triangle - ordinary combustible materials Class B - Red square - flammable combustible liquids Class C - Blue circle - energized electrical equipment Class D - Yellow star - combustible metals (dry powder not to be confused with dry chemical) Class K - Letter K - kitchen, cooking oils (wet chemical) Red slash through any symbol tells you that it cannot be used for that type of fire. Missing symbol means that it has not been tested for that class of fire AN Fall 2004
133
What are some signs of heat exhaustion?
Body weakness, cool sweaty skin, rapid shallow breathing, and dizziness QD June 2002 (heat emergencies)
134
At a gas leak investigation, when is a Level 1 Hazmat requested? (outside / inside)
Outside - when the LEL is greater than or equal to 25% (high LEL alarm) Inside - when the LEL is greater than or equal to 10% (low LEL alarm) or the O2 is less than or equal to 19.5% (low oxygen alarm) or There is an obvious large volume of leaking natural gas in either situation SOP 507.08
135
Members appointed to non-career service rank positions shall personally arrange badge and cap device exchange through CFDHR within?
The time limits on the promotional order GO 18-012 ❗️
136
When charging sprinkler systems, charge and maintain at no less that PSI?
100 PSI GO 93-013 (does not specify non high rise) (Note SOP 210 states 150 psi for *high-rise*sprinkler system)
137
In a high rise fire, who is located 2 floors below the fire floor?
Forward Fire Command Search and Rescue Command Post (RAT) The Scribe (FF from 1st truck after being relieved by the 3rd engine engineer) SOP 210.00
138
If the donor's primary low pressure warning device is not sounding and HUD/control module are not flashing, what is the sufficient amount of air to transfill to a receiver?
Greater than 2000 psi for 4500 psi SCBAs Pressures equalize after approx. 60 seconds using 3ft hose (approx. 40 sec per Multi-Co Ops 18-008) G-1 MSA-SCBA Manual ❗️
139
WHO IS RESPONSIBLE FOR BEDDING HOSE AFTER O700HRS?
THE ONCOMING SHIFT (Hose used or becoming wet after 0700 will be cleaned and hung without delay by the platoon reporting for duty at 0800hrs). G.O. 93-012
140
Don SCBA unit and be on air with facepiece and regulator (aka. demand valve) connected within _____?
1 minute Drills shall be conducted while wearing structural firefighting gear GO 17-018
141
BC Jones orders Truck 96 to chain out the train. Lt Birrueta orders his personnel to place chains in the front of the first car and behind the last car of the train. What is the correct distance from each end of the train to place the chains?
50 feet in front and 50ft in back (Make sure chains are contained in the power shut off zone usually identified the nearest cross streets in both directions) CTA Manual 3.2.5.1
142
At what intervals are the metal rings and knots on the search rope?
At 50 feet- 1 ring (1 knot) At 100 feet- 1ring (2 knots) At 150 feet- 1ring (3knots) Multi Company OPS 08-002
143
How long is the hose the guzzler connects to? | And how far should it be inserted into the hydrant barrel?
8-10 feet long and insert 6 feet into hydrant port SOP 204.00 OO 22-003
144
Where do you obtain an IR# from during disciplinary procedures?
Obtain from IAD during business hours (M-F 0800-1600) or from OEMC non business hours/weekend/holiday **IR # written on the top right corner of all documents submitted** GO 18-009
145
If HEMS LZ is extremely dusty, wet with minimal water when above what degree?
40 degrees SOP 408.00
146
Radio in Box (RIB) Definition:
A 25-watt mobile radio in a portable case, requiring an external power source (110VAC or 12VDC), which increases radio range and allows for better communications compared to 5-watt portable handheld radios. Tested SUNDAYS after 0900 OEMC radio test SOP 210.00
147
What is considered a small spill?
A release involving less than or equal to 208 liters, or 55 gallons Multi Company OPS 16-001
148
How many knots are at each mark on the search rope?
1 at 50ft, 2 at 100ft and 3 at 150ft Rings lead you in, knots lead you out Multi Company OPS 08-002
149
Company member shall remain for a minimum of how many minutes after the apparatus has been taken into the shops for initial inspection?
30 mins Company officer notifies CFD Fleet Liaison via OPS 9 when at guard shack TIC, tablet, AED, drugs, and radios stay with members LO 19-003 ❗️
150
Hand signals for back/reversing?
FWD: Arm extended in front sweeping arm up and down STOP: Sweeping arm in front of body left to right STRIAGHT BACK: circular motion in front of body TURN: Arm extended in direction intended. Opposite hand shall perform either vertical up and down sweep or circular motion depending on if moving forward or reversing. SOP 702.00
151
Fire extinguishers are not required in an area under how many square feet?
Under 3000 square feet - minimum 2A rating TB 1989 Fall ❗️
152
Unprotected lightweight wooden truss assemblies have failed within how many minutes of exposure to fire?
5 minutes SB 07-001
153
How is LDH tested?
In 300 foot lengths at 200psi for at least 5 minutes GO 93-012
154
Within how many hours will the physical signs of mustard agent exposure appear?
4 to 8 hours However damage occurs within 2 minutes SB 18-004
155
What is the high rate alarm on the RadEye?
2mR/hr (LED quick blinking, continuous tone) Establishes the Hot Zone Requires Level 1 Hazmat Rates over 10R/hr LCD will display "OVERLOAD" Multi-CO Ops 21-003 OO 21-004
156
What channel shall be the primary back up for the failure of the digital radio system?
City Wide Fire (Channel 13) SD 12-002
157
Company Officers shall ensure that the RAT Companies are equipped with what?
PPV fan, along with proper eye and hearing protection. SOP 210.00
158
ALL SCHOOL FIRE DRILLS MUST BE COMPLETED HOW MANY DAYS BEFORE THE END OF THE MONTH?
7 DAYS SD 95-002
159
When nature of a Form 2/2A concerns a specific member, what should be written in the top right hand corner?
Members file number and platoon Not addressed to higher than district chief, unless given permission GO 91-016 ❗️
160
A series of maps issued to each Command Van that contains specific information about building height and construction type; and the location and size of all water mains, as well as every fire hydrant connected to those mains, in the City of Chicago.
Sanborn Maps SOP 290.00
161
Ensure members keep how many feet away from downed powered lines?
At least 30 feet SOP 703.00
162
Once deployed, the officer of the RIT team must communicate with the RIT chief via radio every how many minutes?
5 minutes SOP 106.00
163
In a high rise, 2-way stairwell phones are located every how many floors?
Every 5 floors Found in building with 3 or more floors Found on floors with multiples of 5 SOP 210.00 AN Summer 2009 (Fire Alarm Systems)
164
CTA Railcar Shoes:
1. Each car has 4 shoes, 2 on each side 34 feet apart 2. One shoe touching 3rd rail, all shoes energized and all cars CTA Manual
165
1. Company officers check in on Telestaff no later than ____ensuring proper action code and tactical position for each member. In addition to possession of DL and EMS license. 2. No later than ___ officer place members in tactical positions for next shift day 3. No later than _____ officer checks Telestaff roster to review properly staffed for the next shift day
1. 0815 *** in GO 06-010 states to call BC at 0800**** 2. 1100 3. 1600 A yellow or red alarm bell indicates a staffing issue GO 17-010
166
Any building that is 80 feet or more above grade is considered a High Rise. What are the 4 Categories?
Category 1: Over 780 feet in height Category 2: Over 540 feet, up to and including 780 feet Category 3: Over 275 feet, up to and including 540 feet Category 4: 80 feet and over, up to and including 275 feet SOP 210.00
167
Company Officers maintain Floor Watch while the company is in quarters between?
0700 and 2200 GO 14-003
168
What form is used for annual hose testing?
Form 156 GO 93-012
169
What is the length of the RIT pack transfill hose? | What is the length of the officer transfill hose?
25 feet 3 feet 45minute bottle OO 18-002 and SCBA Manual
170
What 3 things does officer conduct when accepting a vehicle?
1. Visual inspection 2. Road test 3. Operational field test If not operating properly: During business hours notify onsite CFD Liaison If after hours/weekend/holiday notify supervisor or Equipment and Supply SD 08-001
171
Within how many minutes will a steel truss roof fail at 1000' (flashover temp)
5 minutes The “rule of thumb” failure time for steel bar trusses is 10 minutes at 1000 degrees (flashover temperature). For the fire service, the recognized failure time is 5 minutes! QD April 2001 ( steel truss roofs)
172
What are some signs of heat stroke?
``` Hot dry skin (no sweating) Altered mental status (possible loss of conscious) Rapid pulse Deep breaths Nausea and vomiting Possible seizures ``` QD June 2002 (heat emergencies)
173
Where are subway emergency exits located?
They are 1000 to 1500 feet apart and marked with an illuminated EXIT sign. They are the primary egress for passengers. Directional signs, located on the tunnel walls, are spaced at 200 ft. intervals. These signs indicate the distance to the closest emergency exit and are NOT illuminated The Subway Location Identification signs are 100 ft. apart. They are reflective and on the subway wall at approx. 9 ft. above the track level. If mass evacuation necessary, it may be safer to use the track bed once power shut down. CTA Manual
174
Upon entering the fire floor, make an inspection hole in _________. Inspection holes can help verify the conditions of structural framing members and uncover areas of hidden fire within the void spaces.
The ceiling above and the floor below AN Winter 2010 ❗️ (Lightweight construction)
175
What does the letter “P” stand for in the yellow bordered pages or the blue bordered page of the ERG?
The material may undergo violent polymerization(violent build up of heat and pressure leading to explosion and/or fire). Non-interventions should always be considered when there is a potential for polymerization Multi Company OPS 20-005
176
After what point is a water rescue considered a water recovery?
After 90 minutes of submersion *first 90 minutes considered Water Rescue mode SOP 508.00
177
What are the elevator procedures in a high rise? 2 answers
6th-19th Floor - Stop once halfway - between lobby and fire and exit 3 floors below fire 20th floor or above - stop at 5th floor, then stop 10 floors below reported fire floor, exit 3 floors below fire SOP 210.00
178
What are the 2 categories of deep tunnel incidents?
1. Toxic (considered Draeger Incident) 2. Non-toxic GO 92-005 ❗️
179
Water must be removed from the barrel of the hydrant how many inches down from grade level to prevent freezing in the winter months?
48 inches SOP 204.00 OO 22-003
180
FF LETZ WAS ON DAILY DAY AND WAS CALLED TO WORK OVER TIME HE ARRIVES AT 0820 AND ASKS LT ZEIGLER WHAT IS THE MINIMUM AMOUNT OF OVER TIME HE WILL RECEIVE.
5HRS CONTRACT PG.12 ❗️
181
Lt Birrueta orders his company to set up an in-line foam eductor. Members lead out sufficient 4", exactly 50 feet of 2 1/2 hose and attach the 1 1/4 SOP with the 1 1/2 x 2 1/2 INCREASER. After attaching the in-line eductor, company members attach the 1 3/4 hose. What is the exact amount of 1 3/4 hose required prior to attaching the 150/75 adj fog?
Exactly 150 feet of 1 3/4 hose Old info from AN fall 2004 (Nozzle fully open and set pattern at 10%-15% fog 3% 80seconds 6% 40seconds) Engine Ops 21-001
182
What nozzle is required when covering exposure structures when fighting an electrical pole fire?
A fog nozzle using a 30 degree fog pattern. **keep streams min. of 10 feet away from energized lines or electrical equipment. SOP 203.00
183
How many gallons or more of flammable liquids require a license?
30 gallons or more of flammable liquids having a flashpoint below 200'F TB 1989 Fall ❗️ AN Spring 2008
184
Doors of occupancy's over 50 shall swing in what direction?
Swing outward TB 1989 Fall ❗️ (In service inspections)
185
What type of radiation does the RadEye G-Ex measure?
Gamma Only •Measures rates 1uR/hr to 10R/hr •Measures doses 10uR to 999R •Normal rater in Chicago 1uR/hr-40uR/hr •Low Battery-hollow battery icon, Low Batt at top of screen, Quick chirp every 8seconds •NBR alarm- may alarm below indicated alarm levels if artificial radiation detected. NBR readings either "LOW ENG", "HIGH ENG", or "BALANCED" with led quick blinking and two frequency tone. Should be Investigated Multi-CO Ops 21-003 OO 21-004
186
What are the mounting requirements for fire extinguishers?
If weight more than 40lbs - TOP of extinguisher no higher than 3 1/2 feet from the floor If weight not exceeding 40lbs - TOP of extinguisher no higher than 5 feet from the floor AN Fall 2004
187
All NON-SPRINKLERED high-rise buildings over ____ feet tall are required to have Smoke-proof Towers.
264 feet SOP 210.00
188
During CO investigation, at what ppm will the low alarm sound?
50ppm or greater The Occupational Safety and Health Administration (OSHA) has established a maximum safe working level for CO at 50 parts per million (ppm) over an 8-hour period in a typical workplace environment. EPA established levels should not exceed 9ppm over an 8hr period for residential. SOP 507.07
189
Which construction type is the most likely to collapse?
Noncombustible QD Sept 2004 (Structural Collapse)
190
The company officer shall immediately notify BAS when there are less than ____ full air cylinders or less than _____ O2 cylinders.
Less than 10 full air or less then 4 O2 All inventory: 30 - 45min Air cylinders 10 - O2 Cylinders LO 17-003
191
What are the 4 products of combustion?
1. (fire gases) 2. flame 3. heat 4. smoke TB 1987-04 ❗️
192
WHAT TYPE OF EMERGENCY IS CHARACTERIZED BY TOTAL BODY WEAKNESS AND COOL SWEATY SKIN?
HEAT EXHAUSTION. Q.D. JUNE 2002 (Heat Emergencies)
193
Justrite Flammable Liquids Safety Cabinet Specs
Stores up to 22 gallons Fusible link that melts at 165' No other flammables stored within 10ft OO 22-010
194
Pressurized portable fire extinguishers must be inspected annually and hydrostatically tested every how many years?
6 years LO 15-005
195
When conducting a PAR, what are the 3 status of PAR?
PAR, PAR in progress, No PAR SOP 105.00
196
What is the minimum distance Lt Birrueta should order the aerial ladder positioned away from electrical wires and components?
Minimum of 10 feet SOP 203.00
197
To prevent whipping during hose testing, the discharge gate should be closed to between______ and ______ before closing the SOP?
Partially close a minimum of 1/2 and maximum of 3/4 GO 93-012
198
When do we drill on APR's?
Saturdays Max work time 8hrs, no more than 2 hours if exposed to liquids, air must be sufficient 19.5%. Mask effective but not specifically approved for protection against riot control agents Contaminate must be determined OO 20-002
199
Hazmat Green Tables Review: Table 1 Table 2 Table 3
Table 1 - No fire - Initial isolation distance Table 2 - Water reactive - which produce toxic gases Table 3 - Lists 6 common TIH (toxic inhalation hazards) for large spills (more than 55 gallons) Multi Co Ops 20-005
200
What size hose should not be suspended from buildings or fire escapes?
LDH GO 93-012
201
Furloughs missed while on duty layup will be reschedule within how many days of release of medical status?
14 days GO 16-006
202
Between what dates shall the Occupational Safety and Health Administration (OSHA) 300A form be posted?
Between February 1st and April and 30th LO 16-002
203
Construction Types per Municipal Code:
``` Type I - Fire Resistive Type II - Noncombustible Type III - A. Heavy Timber B/C. Ordinary Type IV - Combustible Frame ``` Municipal Code Chapter 13-60
204
What are the standards for random drug/ETOH testing?
No more than 20 employees daily randomly. Conducted Mondays through Fridays between 0900 and 1600. No weekend, no holiday. Positive for ETOH is .04 or greater. GO 04-001
205
The City of Chicago Evacuation Ordinance sets a procedure for the evacuation of ____ floors above and _____floors below the fire floor.
2 floor above and 5 floors below SOP 210.00
206
Update E-Form for locker changes within how many days?
15 days following a transfer order or a members retirement **Completed by House Captain GO 18-004
207
Portable radio batteries should be replaced when?
When the multi charger shows "estimated capacity" after charge or the "rated capacity" when fully charged is at or below 78% LED Indicator Light: LED indicator will display RED while transmitting, AMBER while receiving and GREEN while programming/editing Scan lists. APX-7000 Manual ❗️
208
In a high rise fire, who is located 3 floors below the fire floor?
Forward Staging Area Support area ALS Support Engine (with QRAE and assist with the removal of any civilians or firefighters from the Support Area to the Triage Area as required) SOP 210.00
209
During structural collapse incidents, shut down all devices capable of causing vibrations within how many feet of the collapse?
300 feet SOP 209.00
210
A high-rise building under demolition is required to have an operable standpipe until the building is under how many feet?
40 Feet SB 09-002
211
Tenant or building inspections may be conducted a maximum of _____ times.
5 times If the tenant or building fails Recheck-4, they will be referred to the Compliance Board or the Fire Prevention Bureau Court Section by the Office Manager or Chief Officer. FPB Definitions
212
When properly operating, the ejector valve will automatically operate when the compressor tops off the air tanks at what PSI?
120 PSI OO 18-020
213
When possible, the accused shall be notified how many work days in advance of a notification review meeting utilizing Form #909 (Schedule of Notification Review).
1 day GO 18-009
214
If operational issues with radio equipment or infrastructure (dead spot, drop frequencies) what should be forwarded through chain of command to the Deputy Fire Commissioner of operations at CFD HQ?
A radio equipment operational evaluation form GO 12-008
215
What is the easiest way to throw a line at a water incident?
The throw bag - throw bag so the line lands over the victims shoulder Multi-Co Ops 07-005
216
During peaked roof operations, place the aerial ladder at an angle to the ridge board with minimum 5 rungs hanging over it. The base rails of the fly section should be about ____ inches off the ridge board.
6-10 inches off Optimal angle for safely climbing up and down aerial ladder is approximately 70'. The lowest working angle attempted should not exceed 30'. AN Fall 2004 (peaked roof ops)
217
How are lanes numbered on a limited access road way?
Starting with the left lane while facing the direction of travel QD July 2004
218
Green private hydrants may discharge up to what PSI?
Up to 200 psi SOP 204.00
219
How will portable radio relay be implemented during a subway incident?
No more than every 100 to 150 feet from the command post to the incident. Engineer from the 2nd engine will act as communications until the arrival of the command van CTA Manual
220
What are the flammable limits of natural gas?
Approximately 5% to 15% in air SOP 507.08
221
The total collapse of a metal-plate connected wood floor truss can take as little as how many seconds?
7 seconds Late indicators of collapse -falling plaster -sagging floors -swinging doors -cracking glass Multi Company OPS 14-001
222
WHEN RESPONDING AS THE BOX ENGINE ON A STILL AND BOX AND ORDERED TO LEAD OUT UNLESS OTHERWISE ORDERED WHAT TYPE OF HOSE SHOULD BE USED TO CONNECT TO THE HYDRANT?
SOFT OR HARD SUCTION ONLY G.O. 93-013
223
During In-line operations, what intakes should be utilized?
Utilize intakes with gated valves Due to the potential for excessive intake pressure. The air-operated front and rear intakes shall not be used for In-Line Engine Operations SOP 290.00
224
Except in cases of emergency, all probationary firefighters shall be assigned to the fire academy, for a period of at least ___ days immediately after their entry to the Fire Department and before assignment to companies for active fire duty.
90 days GO 13-007
225
If the PTT Button is depressed continually for ____ or more, an Alarm Tone will sound indicating that the microphone was keyed and is now deactivated.
60 seconds **5000 does not state that it deactivates the mic** Radio Manuals ❗️
226
Per code, how are stairwells identified?
1.Directionally or Alphabetically (Letters must be 6 inches in height) If you pass through 2 doors to enter a stairwell, the stairwell is a smokeproof tower. Multi-Co Ops 19-004
227
Where are tail guards positioned at HEMS?
The Tail Guards shall be positioned DOWNWIND outside of the safety perimeter and Approach Corridor on the downwind corners. SOP 408.00
228
What 4 things does the QRAE detect?
CO Hydrogen sulfide LEL O2 Battery fully charged every Sunday Not intrinsically safe when attached to travel charger. OO 22-002
229
Preferred communications at a high rise fire?
Face to face when possible SOP 210.00
230
What considered a radiological investigation?
An investigation to identify the cause of radiation readings above 50 µR/hr. SOP 511.00
231
What flammable liquids are listed in Class I, Class II, and Class III?
Class I - others not listed in II or III, Gasoline, Ether, Acetone, Turpentine, Ethyl Alcohol ect Class II - Kerosene, Fuel Oil #1 Class III - Fuel Oil #2, Aniline, Cresoloe FPBI
232
What are the specs of the search rope?
``` Construction- Kevlar with a polyester core Diameter - 3/8” (9.5mm) Breaking strength - 7,600 lbs. Burn rating - 862 degrees F. Rope length - 200 feet ``` Multi Company OPS 08-002
233
During CO investigation, at what PPM will allow premises to be occupied?
9ppm or less SOP 507.07
234
What do smoke lines indicate?
A smoke line at the halfway point of the doorway is indicating a fire most likely to be on that floor. A smoke line covering the upper 3rd of the entranceway indicates the location of the fire to be above that floor either the attic/cockloft or the floors above. Smoke covering the entire doorway and/or a fully charged structure is a great indication of a fire location being below the main entrance. An Dec 2017
235
What is the twenty minute rule?
If fire occurs on two or more floors or for 20 minutes in an ordinary constructed building, there is strong potential for a structural collapse. If the fire in an ordinary constructed building has not been extinguished in 20 minutes a defensive attack may be warranted. QD Sept 2004 (Structural Collapse )
236
When using the water rescue ring, use if victim is out of reach from the waters edge and within how many feet?
25-30 feet QD May 2002 (Water rescue Using the ring buoy)
237
What is the preferred handline for a prairie/brush fire?
1 3/4 with adjustable fog SOP 205.00
238
What channel is used for communications between FS&R companies and ambulances?
Administrative (Channel 3) (GO 12-008) Or EMS Command Channel 4 (GO 10-002)
239
In the True North L-2 RIT Bag, what prevents the knurled wheel (high pressure coupling) from rotating accidently and loosening?
The Choke Block Truck Ops 17-001 ❗️
240
What fitting is connected to the soft suction on city engines vs O'Hare engines?
City - 4 1/2 male to 4" storz O'Hare - 4 1/2 male to 5" storz Soft suction is 5 inch hose with one 5 inch threaded female fitting and one 4 1/2 inch threaded female fitting SOP 204.00
241
ON WHAT DAY OF THE WEEK ARE TIC CAMERA BATTERIES ROTATED ?
SUNDAYS OO 16-011
242
What form is filled out for damaged hose?
Form 11.202 (Burst,damaged or destroyed hose) GO 93-012
243
What house repairs are considered "emergencies" and who do you notify?
Overhead doors OOS Plumbing Heating system OOS No hot water Notify building maintenance between 7a-3p, or if office closed notify District HQ thru channels An Fall 2008
244
IT IS JAN 1 IT IS 22 DEGREES OUT FF SLATER HAS SET THE THERMOSTAT WHAT IS THE HIGHEST PERMISSIBLE SETTING FOR THE THERMOSTAT AT THE FIREHOUSE TODAY?
69 DEGREES SD 93-002
245
What is a "temporary assignment"?
30 days or longer, up to 90 days Posted on sharepoint for no less than 14 days GO 16-009 ❗️
246
When responding to what incidents do we not use lights and sirens?
1. Citizen Assist 2. Locked In/Locked Out 3. Reset Fire Alarm 4. High Risk Warrant 5. Well Being Check 6. Admin Change of Quarters 7. Picking up member from hospital (ambo assist) OO 17-016
247
G-1 MSA-SCBA Segment Information Review
Segment Pressure range Illuminated LEDs Lit Segment 1 75 to 100 % 4 green LEDs Segment 2 50 to 74 % 3 green LEDs Segment 3 36 to 49 % 2 yellow LEDs Segment 4 0 to 35 % 1 red LED G-1 MSA-SCBA Manual ❗️
248
What is the DOSE alarm on the RadEye?
3R (continuous tone, vibrator slow) Overload in dose will display "OVLD" Multi-CO Ops 21-003 OO 21-004
249
If smoke conditions are encountered in the Evacuation Stairwell, direct occupants onto a floor where conditions are tenable. Immediately notify who?
Immediately notify Lobby Command - So that an alternate exit route can be located or modifications can be made to remove the smoke from the Evacuation Stairwell. SOP 210.00
250
If defensive operations are being used in a Red X building, who decides when an interior attack will take place?
Only a Battalion Chief. (a Company Officer, serving as Incident Commander until the Battalion Chief arrives, may NOT make that decision) Multi Company OPS 13-007
251
When placing a ladder, what is the optimal distance of the base of the ladder from the building?
1/4 the distance of the height QD Dec 2002 ( One person 24ft ladder raise)
252
When cutting DAWGS windows, where should you line up your saw and start cutting?
Use the outer edge of the vent patterns Make 2 12-16in vertical cuts from top to bottom on one side of the panel, then swing open 180' Truck OPS 11-004
253
When is annual inventory due at district?
July 1st GO 93-006 ❗️
254
When does BAS automatically respond?
1. 2-11 or greater 2. Still and Box in a high rise 3. Hazmat Level II or greater 4. IC request LO 16-003
255
Only the ______ has the option of placing the Electronic Pressure Governor in the RPM or Pressure Mode?
Supply Engine (All others in RPM) SOP 290.00
256
LT. LINK WOULD LIKE TO CONDUCT IN SERVICE FIRE PREVENTION INSPECTIONS (TOCs) FF LETZ ASKS HER DURING WHAT TIMES CAN TOCs BE CONDUCTED?
BETWEEN 1000-1200HRS AND 1300-1530HRS SD 95-002
257
What are the steps for using the threaded hydrant port adapter?
Attach with the threads facing out, handle upright at 12'oclock, turn counter clockwise (to the left) quarter turn OO 17-015
258
When are Chicago Park District lifeguards on duty?
Beginning Memorial Day weekend and ending on Labor Day, from 1100 to 1900 hours. SOP 508.00
259
During in-line operations, pressures need to be provided between ___ and ___ PSI intake pressure on the compound gauge of any receiving engine?
20 and 60 PSI SOP 290.00
260
Duties of HIT Engine Duties of HIT Truck
Dispatched to Leve lI or Level III HIT Engine - set up and staff formal DECON HIT Truck - set up and staff DONNING and DOFFING area OO 22-001
261
When the 4 digit UN/ID number is known, what color section of the ERG should be used?
Yellow Multi Co Ops 20-005
262
VISITORS ARE PERMITTED IN THE FIREHOUSE DURING WHAT HOURS?
0930-2100 HRS G.O. 00-003
263
Due to the varied potential hazards associated with incidents arising at distilleries, arriving company officers may consider requesting the following specialty apparatus based on initial size-up of the incident:
1. Request a Level I Haz-Mat response (meters that will allow for metering of ammonia). 2. If fire is present, immediately request the dispatch of the following: A) Bulk Foam Unit (AR-AFFF used for this) B) Dry Chemical Unit C) High-Expansion Foam Unit The threshold level for a dust explosion used by OSHA for citation purposes is 1/32 of an inch over 5 percent of the total surface area of a facility. Multi-Co Ops 16-002 ❗️
264
WITH EXCEPTION TO UNSEASONABLE WEATHER DURING WHAT DATES IS IT PERMISSIBLE TO USE HEATING SYSTEMS IN THE FIREHOUSE ?
SEPTEMBER 30TH THROUGH MAY 15th SD 93-002
265
How many feet of 5 inch hose does the hose wagon carry?
5000 feet (usually 100 feet per length) SOP 290.00
266
RASP Team Members names and roles:
All Positions have radio and light in addition to below Position 1 - Officer - TIC and rope bag - first to enter last to exit - uses back scan method to look back at RASP members with TIC for accountability Position 2 - Irons - flat head or sledge and halligan - first member to conduct rapid room search - specifies to leave axe or sledge at door when entering to search Position 3 - Hydraulic tool - has either rabbit tool or hydra ram in supplied carrying case also leave at door when entering a room Position 4 - RIT Pack - last member to search in a smoke filled or fire threatened area. Leads the way for exit Position 5 - Control - per the manual it states Chief preferred for this position. Monitors time on air. If radio issues Positions 1, 4 and 5 MUST have radios RASP Manual
267
What form does the officer prepare when an employees immediate family dies?
FD 920 GO 95-007
268
How old does a newborn infant have to be, to be relinquished to a "Safe Haven"?
Believed to be 30 days or less Parents must return within 72hrs to be give name and location of hospital GO 10-013
269
How long does an employee have to submit a Written Statement of Facts?
72hrs for FS and R and 96hrs for EMS GO 18-009
270
When conducting TOC's, what are the structure and tenant codes?
If a building is empty, the structure inspection form should be marked (LOO1 in the Occupancy classification), however, if only a tenant is vacant you will mark the tenant vacant (LOO1) on the tenant inspection form. For the most part, the structure will remain (MOO1 Mixed occupancy). You now have the option , if you have the structure form, to put in more than one occupancy classification ie; MOO1 and LOO1. For the most part this would signify that the building is occupied and the tenant is vacant. TB 1989 Fall. ❗️ (In service inspections)
271
CTA Chain out sequence:
1. Wrap around running rail furthest from 3rd rail 2. Using 10ft fiberglass pikepole place chain across 3rd rail 3. Wrap twice around 3rd rail and anchor hook to link CTA Manual
272
What is considered a radiological event?
Confirmed radiological readings above 2mR/hr from a legitimate source which has not been released from its container or is not a naturally emitting source. Request level 1 hazmat and CPD SOP 511.00
273
According to the Rules of The Road, what are the speed limits for: Alleys City/Town Areas School Zones
Alleys - 15mps City/Town Areas - 30mph School Zones - 20mph 7a-4pm Rules of the Road
274
How many days suspension do you get for aggression/threat?
3-9 days non emergency scene 9-15 days on emergency scene GO 00-001
275
What are the two types of electrical lines?
Primary lines: Carry between 4,000 to 25,000 volts. Run at the highest point, are seated on ceramic insulators and are spaced approx 1 foot apart. Secondary lines: carry between 120 and 240 V. typically run below primary lines and are spaced 4 to 8 inches apart. SOP 703.00
276
Describe the proper placement of the PPV fan?
4-6 feet directly in front of the doorway at an 80' angle Truck OPS 13-001
277
In a residential building, a door that swing towards you would likely lead you in or out of a room?
Leads you out SB 19-002 ❗️
278
Time loss for stopping at a red light or a stop sign is only how many seconds?
2-3 seconds SB 08-006
279
What is located in the inner perimeter at an ASI/ATI?
1.Forward command post 2.triage Patient hand off point located within PROTECTED AREA Family briefing area located Outside OUTER PERIMETER SOP 602.00
280
When encountering all boards systems (VPS, DAWGS) and manpower is inadequate, which is removed first; windows or doors?
Windows Truck OPS 11-004, Truck-OPS 10-002
281
I-joist have experienced totally collapse in how many minutes?
6 minute AN Winter 2010 ❗️
282
ON THE WAY TO WORK ENGR RUIZ RECEIVES WORD OF THE DEATH OF HIS BROTHER IN LAW. HE ASKS LT DUPONT WHAT HE SHOULD DO TO TAKE BEREAVEMENT LEAVE. WHAT SHOULD LT DUPONT TELL HIM REGARDING BEREAVEMENT LEAVE FOR HIS BROTHER IN LAW?
BEREAVEMENT LEAVE WILL BE GRANTED FOR THE DAY OF THE FUNERAL ONLY. "Note: no mention of brother or sister in law in bereavement leave GO" CONTRACT PG 48 ❗️
283
What is recommended for lifting when a patient is in the stretcher?
At least two people on each side from the bottom rails. AN Sept 2001
284
What are the PAS tags connected to when members are inservice?
Apparatus ring collector (which is a 3 inch ring connected to a 6 1/2 inch carabineer) Unit tags are also connected to 6 1/2 inch carabiner GO 14-006
285
What are the specifications of a "RED X" building?
Structures that contain 30% or more structural deterioration. Subject to sudden collapse. Placards 2x2 usually located on side A and C. SOP 262.00
286
When are SCBA batteries changed?
1. Engine -1st Sunday 2. Truck/TL -2nd Sunday 3. Hazmat/Squad -3rd Sunday 4. Chiefs -4th Sunday GO 17-018
287
FIRE FIGHTER KNOLLS IS HELD OVER FROM THE PREVIOUS SHIFT AND IS NOT RELIEVED UNTILL 0820. HE ASKS LT DUPONT HOW MUCH OVERTIME HE WILL RECEIVE.
30MIN OF OVERTIME (NOTE: Not compensated for clean up or changing of clothes per GO 92-009) 0815- 30mins After 0830 - 1 hr 0845 - 1 hrs After 0900 - 1.5hrs CONTRACT PG.12 ❗️
288
Truck 96 responds as a RIT Truck to a working fire. What channel should the members of Truck 96 use if a "mayday" is transmitted and RIT is deployed?
Channel 4 (fireground) SOP 102
289
Patients having excessive radiological contamination shall be decontaminated before transport, what is considered excessive contamination?
Initial Background meter reading x3 Multi-Co Ops 21-003
290
In a lightweight constructed building where the roof and floor have been exposed to fire, firefighters should always be alert for structural collapse. How soon after structural members have been exposed to fire can structural collapse be expected?
5-10 minutes AN Feb 2002 (Light weight truss construction)
291
DAWG Door Systems Identification: 3 types
1. Mechanical - rectangular box on diamond plate with padlock - when opening from interior consider inserting the blade of a screwdriver into the release mechanism and turn counterclockwise 2. Electrical - slit on diamond plate 1/3 of the way down ***both of the above have spring loaded pins attached to cable. If cable cut, pins default into locked position*** 3. Exit Door Only - no hardware on diamond plate, manual interior release Make diagonal 45' angle cuts on both the upper and lower corner of door, then cut center (deadlock) pin 2in inward from the door frame Truck OPS 11-004
292
If the badge and/or cap device has not been recovered or repaired within how many days, the member will be financially responsible for the replacement badge and/or cap device?
30 days The member may be subject to a wage deduction equivalent to a 10 hour suspension GO 18-012 ❗️
293
Who is responsible for notifying HEMS that a response might be required by CFD?
OEMC SOP 408.00
294
AFTER ALL NATURAL OPENINGS HAVE BEEN USED WHAT IS THE MINIMUM SIZE HOLE THAT SHOULD BE CUT IN A ROOF ?
4X4 SIZE HOLE AT LEAST 5ft FROM EXTERIOR WALL AN SUMMER 2004 (Flat roof ops)
295
Per the contract, how many paid days for the Reserve Forces and the National Guard?
1. Reserve Forces - 14 calendar days in a calendar year 2. National guard - 15 calendar days in a calendar year Contract ❗️
296
What are the requirements to receive at least 20 mins of rehab during in-service/training?
1 hr of physical activity 45mins in chemical protective suit Does not require formal rehab, ambo or chief SOP 107.00
297
Trade Rules per the Contract
Max of 12 trades each half year Max of 4 consecutive trades Max of 20 calendar days (no furloughs) Max of 35 calendar days (using furloughs) All paybacks must be completed within 4 months Submit a min of 2 work days prior Contract ❗️
298
How should members approach burning autos? (not including a pin in)
Upwind uphill at a 45 degree angle, wearing full PPE including SCBA, with a minimum of 150 ft of 2 1/2 with 1 1/4 SOP. Also bring dry chem ansul and forcible entry tools. SOP 206.00
299
What are the 4 forms of heat transfer?
1. Direct contact 2. Radiation 3. Conduction - Through a solid 4. Convection - Upward TB 1987-04 ❗️
300
After being properly relieved, at what time are member allowed to leave quarters?
After 0700 GO 91-001
301
What does the green dot indicate on the APX-7000 radio battery?
That it is intrinsically safe. Clean with 1tbsp of dish soap to 1 gallon of water (.5% solution) apply sparingly with stiff, non metal brush APX-7000 Manual ❗️
302
Hose not used after how long will have water passed though it?
6 months GO 93-012
303
Only the ____ engine has the option of placing the Transfer Valve in the Volume or Pressure Position.
Attack (All other in volume) SOP 290.00
304
A staging area shall be set a minimum of how many blocks away?
Minimum of 2 city blocks from incident GO 03-004
305
Name some unusual characteristics of a high rise building
Beyond the reach of Fire Department aerial equipment; Poses a potential for significant stack or chimney effect; Requires unreasonable evacuation time Smoke spread is the most significant life hazard problem existing Stack Effect: The natural movement of air inside a building, created by the difference between the inside and outside air temperatures and the height of the building. Cold weather - stack effect draws smoke and fire gases to travel upward Warm weather - stack effect draws smoke and gases to travel downward As the height of the building increases, the Stack Effect can become more significant. TB 1986-05
306
In a hazmat situation dealing with an unknown material, which guide should be followed until more information becomes available?
Guide 111 (Or for potential mixtures even if both products are known) Multi Co Ops 20-005
307
How should you approach prairie fires?
DOWNHILL,Upwind (only one this way) from the flanks of the fire SOP 205.00
308
What is the primary danger for firefighter on a steel truss roof?
Falling into the hole they are cutting QD April 2001 (Steel truss roofs)
309
The FIT Engine ensures that the Fire Attack Stairwell has been cleared of building occupants for a minimum of ___ floors above the fire floor.
5 floors SOP 210
310
Captains and Lieutenants are responsible to be familiar within what respective area?
Still district GO 98-003 (Lt.) GO 98-004 (Capt.)
311
IT IS MID SUMMER AND IT WILL BE 89 DEGREES TODAY. WHEN SETTING THE AC AT THE FIREHOUSE IT SHALL NOT BE SET LOWER THEN WHAT TEMPERATURE?
78 DEGREES SD 93-002
312
What does LIP stand for in a mayday situation?
L-ocation I-dentification P-roblem SOP 102.00
313
Ensure that diesel apparatus are not shut off if temperature drops below what degrees?
40 degrees OO 18-020
314
When notified to enact Enhanced Steady State Operation, companies turn PRD (even in quarters). If readings above 50uR/hr, how should you contact the OEMC to notify?
Contact OEMC via means other than radio to inform. SOP 511.00
315
When do you immediately ring the bell for exempt rank chief officers and dignitaries?
Between 0700 and 2100 When a higher ranking Officer or dignitary of higher status is already in the Company’s Quarters do not ring bell. The Company Officer shall immediately notify the visiting Chief Officer of the reason why the alarm bells were not rung GO 14-001
316
Who does the RAT team notify if occupants are encountered above the fire floor in the Fire Attack Stairwell?
Forward Fire Commander Escort building occupants who do not need medical attention out of the Fire Attack Stairwell and relocate them to a safe area (for example: the Evacuation Stairwell or another safe location a minimum of four floors below the fire floor). SOP 210.00
317
What are each of the colors in the ERG used for? Yellow, Blue, Orange, Green
1. Yellow - Material listed by ID # 2. Blue - Material listed by name 3. Orange - Guides (guide 111 for unknown) 4. Green - Equals Tables 1, 2 and 3. If not on fire, go directly to Table 1. Initial Isolation and Protective Action Distances If material highlighted in green in the yellow or blue pages it's a toxic inhalation hazard, a Chemical Warfare Agent, or a Dangerous Water Reactive Material (produces toxic gas upon contact with water) Multi Company Ops 20-005
318
What 3 steps can be used to determine whether rail car is energized?
1. FEEL-feel for vibrations 2. SIGHT-Main interior lights on (Single light on over exits power may be turned off in that car) 3. SOUND-Motors can be heard Check 2nd car of married pair CTA Manual
319
1. What is candidates' field evaluation period? | 2. What is a candidates' probationary period?
1. Eval is 12 months post fire academy 2. Probation is 9 months from date of hire GO 17-009
320
When writing in the company journal, when do you begin the new numerical order count of runs?
Beginning of each month GO 13-017
321
Change siren cadence not less than _____ from intersection?
200 feet AN Summer 2009 (Safe Fire Ground Operations) TB 1996-10
322
What channel should be used to communicate with IDOT?
Admin (Channel 3) QD July 2004 (Interstate Incidents)
323
What is the minimum amount of hose an Engine Company must have to remain In Service after a fire?
500 feet of serviceable 2 ½-inch hose and 1 length of serviceable large diameter or soft suction supply hose Any less than 500 feet is considered being in "Limited Service" GO 14-002
324
How many feet is the initial minimum isolation distance per ERG?
330ft - in all directions (1/2 city block) In cases involving spontaneous release of an entire vessel DOUBLE initial isolation distance. Multi company OPS 20-005
325
The Skeleton Key Locking Security door, inward-swinging model is primarily found only on structures that are ready for ______.
Demolition Can also use rabbit tool to open Truck OPS 10-001
326
VPS Window Review
Attachments points on the face of the panel indicate the use of cables of rods Springs on the side indicate cross bar Removal sequence: one of the bottom attachments, then the opposite top, followed by other top attachment point (7 or backwards 7) Riveted or threaded anchor punch hole around rivet or anchor to enlarge hole with pike end of haligan If cross bar used do not cut down middle cut 6in from edge starting at the bottom Truck OPs 10-002
327
Who monitors the support area for elevated levels of CO and other hazardous gases at a high rise fire?
ALS Support Engine SOP 210.00
328
To what temperature should the hot water heater at the firehouse be set to?
105' SD 93-002
329
What type of hoistway door keys are part of the elevator tool bag?
1. T key 2. Lunar key 3. GAL "M" lock key for swing doors with M or N type interlocks 4. Otis 2 section (1 knuckle) emergency door key with 5.76" shaft 5. Otis 3 section (2 knuckle) emergency door key with 5.76" shaft OO 16-017
330
TeleStaff passwords are reset by who?
Manpower,DDC,ADCP, BC,PFC (Cannot be reset by 4data) G.O. 17-010
331
What is considered a large spill?
A release involving more than 208 liters, or 55 gallons Multi Company OPS 20-005
332
Per the Elevator Manual, it is imperative to keep a member where to ensure the elevator remains in Phase 1 and for communications with member in the elevator.
At the key switch In the lobby **Note: not referenced in any other study material but highlighted in manual** Elevator Manual
333
How many seconds after power to 3rd rail is cut off and an operator shuts power off to rail car will interior emergency lights above side doors come on?
20 seconds When designating "sides" Side A- platform side Side B- left side Side C-wall side Side D Right side CTA Manual
334
DURING WHAT TIMES IS IT PERMISSIBLE TO CONDUCT SCHOOL FIRE DRILLS?
BETWEEN 0930-1100HRS AND 1300-1400HRS SD 95-002
335
What hose lines are not permitted during defensive operations?
The use of 1 3/4 and 2" shall not be permitted SOP 207.00
336
On layup, Employees can receive unannounced visits from medical between ___ and ____ including weekends and holiday?
1000 and 2000 GO 16-006
337
What criteria must be met when using the Fire Boat as the Supply Engine?
1. Mooring location must be a minimum of 12 feet deep 2. Lead Out shall not be greater than 500 feet of 5 inch hose. SOP 290.00
338
Companies shall not perform in service inspections when the temperature is below ______ degrees?
20 degrees Or during Fire Prevention Week SD 95-002
339
How should you position the apparatus when responding to an automobile fire?
At least 100 ft away and offset at a 45 degree angle to protect members. SOP 206.00
340
When using the floor below pipe, the engine connects to a standpipe where?
2 floors below fire floor OO 18-006
341
UPON RETURNING TO DUTY AFTER TAKING A BEREAVEMENT DAY, HOW MANY DAYS DOES FF FODOR HAVE TO FORWARD A CERTIFIED COPY OF THE DEATH CERTIFICATE ?
30 DAYS GO 95-007
342
For how many months from their continuous service date do probationary uniformed members wear their department issued candidate helmet shield?
18 months GO 15-008
343
What information must be entered into the journal upon relief of a member completing tour of duty?
1. Member being relieved 2.Member reporting for duty 3.SCBA harness number 4.Exact time GO 91-001 **Note: in GO 17--018 it states after 0800 inspection to list Members Last name, harness number and cylinder pressure***
344
Downed Firefighter Steps
1. Approach the victim - assess for level of consciousness 2. Roll the victim onto his or her back - identify and address air concerns 3. Silence Alarms 4. Retransmit and confirm Mayday 5. Exit or shelter in place Multi-Co Ops 13-006
345
How many TIC's does the squad bring to a high rise fire?
2 Squad - Initiates primary search of the floor above the fire floor. Any fire extension shall be immediately reported to Fire Attack Chief. They also investigate any stalled elevators to ensure there are no trapped occupants. If any Blind Shaft elevator rescues or any other special rescues need to be made, request a second Squad Company through Lobby Command. SOP 210.00
346
When an emergency evacuation is initiated, apparatus drivers will activate their horns with a series of short blasts for how many seconds?
30 seconds SOP 104.00
347
LT DUPONT ASKS HIS ENGINEER AT WHAT LEVEL SHOULD FUEL BE KEPT DURING TIMES OTHER THEN COLD WEATHER?
1/2 FULL OO 18-020
348
An ambient temperature of what degrees or greater has a large effect on dispersal of contaminates?
86'F Multi Company OPS 20-005
349
Flames/smoke observed pulsating in/out at a high rise are indicative of a what?
Wind-driven fire Lapping Effect: The spread of the products of combustion up the exterior of the building, exposing the floors above the fire to smoke, heat, and ignition. Auto Exposure: The significant radiant heat and/or direct fire contact will cause the windows above the fire to fail, leading to rapid ignition and extension of the fire. SOP 210.00
350
WHEN ARRIVING ON SCENE AS A SECOND TRUCK IN ADDITION TO PARKING AT THE MOUTH OF THE ALLEY WHERE ELSE COULD THE SECOND TRUCK BE POSITIONED CORRECTLY?
ON AN ADJACENT BLOCK TO THE INCIDENT Q.D. Nov 2003 (Apparatus Placement)
351
Members shall clean their protective hood by machine washing in cold or warm water not to exceed ____ F' and machine drying on low heat or air drying out of direct sunlight?
130'F GO 16-005
352
Multi Agency Incident Response definitions review: Branch | Branch, Division, Group, Section, Strike Team, Task Force
Branch: At a large-scale incident, an organizational entity that is dedicated to a major FUNCTIONAL or GEOGRAPHICAL aspect of incident operations. SOP 601.00
353
FF JONES WAS CALLED WHILE ON SHIFT TO WORK HIS DAILY AND ACCEPTED. HE ASKS LT DUPONT WHAT IS THE MINIMUM AMOUNT OF OVER TIME HE WILL GET PAID IF HIS REHIRE DOES NOT GO THE FULL DAY.
4 HRS CONTRACT PG.12 ❗️
354
How many days suspension do you get for provocation/verbal abuse?
Written reprimand-3 days non emergency scene 3-9 days on emergency scene GO 00-001
355
What hose is connected to the hydrant by supply engines at a still and box?
Hard or soft suction (Supply engines at extra alarm fires connect directly to the hydrant via hard suction only) SOP 290.00
356
Money or gifts shall be reported through channels to the Fire Commissioner within how many days?
5 days GO 13-007
357
In what zone is decon established?
Warm Zone SOP's and GO 03-004
358
Who do you notify if the PDT is inoperable
Immediately notify OEMC and District Headquarters SD 10-001
359
What are trench rescue specs?
1. Any trench 5ft deep or greater shall be protected 2. Trench open for 24 hrs is considered long term 3. Stop all sources of vibration 300ft in all directions 4. The ends are the strongest 5. Secondary collapse is #1 cause of death to rescuers 6. Dry chem used to mark cracks or fissures 7. Use rope to identify victims location in case of secondary collapse AN April 2001 (Trench Rescue)
360
Every how many minutes is a progress report given to the OEMC?
At least every 15mins until emergency under control. Then every 30mins until companies are released. SOP 111.00
361
What pitch can a saw be safely operated?
4/12 pitch QD August 2003
362
Company officers with Air Banks shall complete an inventory and enter the results in sharepoint before what hour?
0900 hours Engine - 10 - 45min Truck/TL - 11 - 45min Squad - 13 - 45min / 9 - 60min Hazmat - 10 - 45min / 8 - 60min Airport Crash Rig - 1 - 60min per harness assigned All other - 1 - 30min bottle per harness assigned LO 16-003
363
For Blast Incident, if decon will be required, where is the warm zone established?
For a High-rise, Warm Zone and decon may be established on the floor below the Blast Hot Zone. For a below grade incident the Warm Zone and decon shall be established at street level SOP 509.00
364
Who is in charge of visually directing a landing helicopter into the LZ using LZ Hand Signals?
LZ Officer: The Truck Company Officer OPS Channel 8 used to communicate between the LZ Commander (BC) and the pilot SOP 408.00
365
On the CFD what is the most versatile ladder?
35' / 38' foot ladder QD Oct 2002 (Ladder selection and placement)
366
Name 2 general types of Flows that occur during a fire
1. Bi-directional Flow 2. Uni-directional Flow Multi Company OPS 15-002 (Flow Path)
367
How is SCBA Facepiece protective pouch marked?
With white or sliver marker 1" letter parallel to the flap GO 17-020
368
WHAT ARE INDICATORS OF FROSTBITE?
WHITE OR GRAYISH SKIN, HARD AND WAXY WINTER EMERGENCIES 2009
369
What 2 leadouts require a second line (2-1/2 with 1 1/ 4-inch shut-off pipe) to be lead out to act as a backup? (2 line leadout)
Fixed fog Nozzle and a Fog Basement Pipe GO 93-013
370
Who do you notify if a company is going out of service for a mechanical or electrical issue?
1.Fire alarm office (OEMC) 2.Division of Equipment and Supply IF notified by Fleet that it will be necessary to EXCHANGE and apparatus notify 1.Division of Equipment and 2.Supply District through chain of command Provide: -company # -Apparatus # -Whether its assigned or spare -whether it can be driven or needs tow SD 08-001
371
During CO investigations, when should you don SCBA facepiece?
100 ppm or greater - order occupants out Request Level 1 Hazmat. Consider level 2 if high level of occupants. SOP 507.07
372
What fire must include the formal establishment of rehab?
Any bona fide still and box or extra alarm fire SOP 107.00
373
Reduce aquastat settings on heating system to season?
Spring 150', fall 160°, winter 190°, SD 93-002
374
What 4 things does the multi gas monitor?
1. O2 2. LEL (methane) 3. CO 4. Hydrogen Sulfide SOP 507.07
375
Where is RIT staging located at a high-rise fire?
1 floor below the fire floor SOP 106.00
376
You can store no more than ____ lbs. of L. P. G. (liquified petroleum gas) within a building.
300 lbs. 2 most popular size cylinders for fork lift trucks are 33lbs. and 43lbs., so this would permit within buildings 6 - 43 pound cylinders or 9 - 33 pound cylinders. L.P.G. has a flash point of 156°F. and is 1 1/2 times heavier than air FPBI
377
What form is filled out by the officer after an employee exposure incident?
Form 160 GO 19-003 ❗️
378
UNIFORM PERIODS OF WEAR:
Sep1 to May31 - Class B or D June1 to Aug31 - Class C or D April, May, Sept and Oct are optional months GO 16-001
379
How are 1 3/4 and 2 1/2 hoses tested?
In 300 foot lengths at 250psi for at least 5 minutes GO 93-012
380
What is the fire rating for glass block?
Minimum of 45 minutes up to 90 minutes Some larger glass blocks windows will have reinforcement wire imbedded into the mortar in every other row QD Dec 2001 (Venting Glass Block)
381
Elevator Notes:
1. The emergency stop switch does not operate when in Phase I and in flight 2. Phase I switch located in left hand jam, 6feet 6inches from floor and approx. 4inchs from head jam 3. The counterweights weigh as much as an empty car plus one-half of its rated live load. 4. Hoistway doors are a Class B rating (1 1/2 hour) Elevator Manual
382
Emergency alerts are repeated every how many minutes?
15 minutes by IC or Command Van until secured OO 19-003
383
Under non-emergency conditions, what are the min and max numbers of drivers training and operational training Officers should enter on their shift before 2100?
Minimum of .5hrs for drivers training Max of 1 hr Operational Training Max of 1 hr of Drivers training for certified operators Max of 2 hrs of Drivers for those seeking certification Officers select 0.0 under the time spent driving and time spent operating into the eVOTR only if their apparatus does not leave the firehouse before 2100 GO 15-005
384
What is the low rate alarm on the RadEye?
50uR/hr but below 2mR/hr (LED slow blinking, two frequency tone) Indicates need for an INVESTIGATION Multi-CO 21-003 OO 21-004
385
Are SCBA's required on prairie fires?
No SOP 205.00
386
BLEVE Definition?
Boiling Liquid - Expanding Vapor Explosion Liquified gases most likely to BLEVE FPBI
387
In an MRI Center, the magnetic field can extend up to how many feet from the machine?
20 feet Remember the magnet is always on SB 19-001 ❗️
388
Mass Decon Procedures
Position engines (2) 20 -25 feet apart, officer sides face each other. Charge to 50psi, 2 side ports and 2 rear used Disrobing removes 80% of contaminates Use cold water If temp between 64' and 35' victims sheltered in heated indoor space after If below 35' decon by opening several sprinkler heads indoor AN Sumner 2004 ❗️
389
How is the stand alone PASS device worn?
On the webbing of the Utility Belt, between the belt end clip and the “D” ring approximately 3 inches from the “D” ring, on the flashlight clip, or when wearing chemical protective clothing when harness doesn't have one. On a daily basis, immediately after completing the 0800 SCBA inspection, run through a complete functional test of the alarm stages On FRIDAYS, include BC devices in morning inspection Trucks have 2 BC have 8 Squad/Hazmat have 6 OO 18-001
390
Turn the bypass valve which direction to fully close?
Clockwise G-1 MSA-SCBA Manual ❗️
391
What are the hours of Medical Division?
0800-1600 M-F GO 16-006
392
The medical inventory E-Form must be submitted on a daily basis by _____?
1100 GO 18-002
393
What are the flammable liquid storage classes according to flashpoint?
Class I - flashpoint below 100' Class II - flashpoint above 100' but below 140' Class III - flashpoint above 140' but below 200' AN Spring 2008 (Flammable Liquid Storage)
394
Name the five general types of collapse?
1. Pancake - found in voids created by equipment or furniture 2. V-Shape - found near wall areas 3. Supported Lean-to - found along wall area which did not collapse 4. Unsupported Lean-to - will require shoring under unsupported floor or roof before search can be conducted- does not specify where victim found 5. Cantilever - found along center bearing wall which did not collapse QD Sept 2004 (Structural Collapse)
395
In a zoned standpipe system, in a building exceeding 275 feet, no individual zone will exceed how many stories?
20 stories SOP 210.00
396
AT A MINIMUM HOW OFTEN SHOULD ON DUTY COMPANY OFFICER CHECK THE STATUS OF APPARATUS DRIVERS, DRIVERS LICENSE?
DAILY G.O. 06-013
397
All but how many discharge ports should be capped on the engine during cold weather?
2 Ensure transfer valve in volume OO 18-020
398
What is considered the "Electrical Hazard Area"
At least 1 span (the distance between 2 electrical poles averaging 100 to 150 feet) SOP 203.00
399
How often is hose changed/rotated?
At least 1 bed each week. All hose rotated/changed once a month. Hard and soft suction inspected once per week GO 93-012
400
What info does 1st arriving company report over the radio on a fire scene?
``` A. Company # B. On Scene C. Address D. Direction of travel E. Wether fire or smoke are showing ``` If smoke or fire are showing: F. Construction type of building G. Height GO 03-004
401
AC - 100 Jump Bag Specs
1. 20x25 feet 2. 9 feet tall 3. 3 minutes to inflate 4. Rated to withstand a jump from 100ft approx. 10 stories, 60 second refill between jumps 5. Jumper lands in sitting position 6. If wet, re-inflate within 2 days to prevent rot Multi-Co Ops 17-003 (AC-100 jump bag)
402
Who designates the fire attack stairwell and the evac stairwell at a high-rise fire?
The FIT Team Leader (first arriving truck officer) SOP 210.00
403
What do the FIT Team and 2nd engine and truck bring to a subway fire?
FIT Team - 200ft of 2 1/2 with SOP, 250/50 fog and ansul - to the fire scene 2nd Engine and Truck - 100ft of 2 1/2 with SOP, 250/50 fog, 100ft of 1 3/4 with 150/50 fog, ansul - to the platform area It may be necessary to drop a line down a ventilation shaft to reach fire CTA Manual
404
How often shall fire escapes be scraped and painted?
At least once every 3 years TB 1989 Fall ❗️ (In service Inspections)
405
How should a fog pattern be used for hydraulic ventilation?
The fog pattern should be set between 30 and 60 degrees, and the stream should fill 90% of the window opening Multi Company OPS 14-001 (Basement Fires)
406
On double deck elevators, who must recall the elevator?
Building Engineer must recall Phase II switch is located in upper car Elevator Manual
407
What dangerous buildings are generally found to be the most untenable under fire conditions?
Building under demolition SOP 262.00
408
In the subway, emergency phones located every 800 feet are indicated by what?
A BLUE LIGHT CTA Manual
409
What does the acronym COLLAPSES stand for?
``` Construction type Occupancy loading Lightweight building materials Length of burning time Ankle deep or accumulating water Plaster sliding off walls and falling from ceiling Special Considerations Exposed Steel Sounds inside or outside the building ``` QD Sept 2004 (Structural Collapse)
410
The incoming commanding officer shall conduct a physical inventory within how many scheduled working days after reporting to his/ her new assignment?
3 working days GO 93-006 ❗️
411
CTA Subway 3rd Rail Specs:
1. 600 volts DC 2. Can be powered by 2 substations (current can come from 2 directions) 3. Sits in insulator chairs 6 1/2 inches higher than running rails. 4. Insulator chair spaced 8ft apart 5. At stations, 3rd rail opposite platform 6. Gaps in 3rd rail may span up to 40 feet. CTA Manual
412
What four factors can change flow path?
1. Actions of residents 2. Impact of fire 3. Actions of firefighters 4. Wind Multi Company OPS 15-002 (Flow Path)
413
ROS Platform Review:
1. Issued to each Truck, Aerial Tower, TL , and Squad 2. 48-inch working platform 3. The maximum allowable working weight is 750lbs. 4. Members use Rescue Tech Corona Truck Belt with Ladder Hook to secure themselves to the roof ladder at all times prior to working on the ROS Platform. OO 17-006
414
OCCUPANCY CLASSIFICATIONS Per FPB Inspection Control Document Definitions:
OCCUPANCY CLASSIFICATIONS ``` A1-Single Family Dwellings A2-Multiple Dwelling Sleeping Accommodations: 10 or more- A200 Multiple Dwelling A206 Hotels A210 Public Sleeping Accommodations A203 High Rise ``` B Institutions B100 Institutions C100 Large Assembly (300 or more) C100 Large Assembly C111 Restaurant C112 Night Club C2 Small Assembly (Less than 300, More than 100) C200 Small Assembly C211 Restaurant C212 Tavern Note: Restaurants and Taverns not more than 100 See Occupancy class "F” ``` ********C3 School******** C300 Schools C301 Type 1 k-12 C302 Type 2 Colleges/Adult Learning C303 Type 3 Day Cares Only ``` D Open Air Assembly D100 Open Air Assembly *******E BUSINESS UNIT******** E 100 Business Unit ********F Mercantile Units********** F100 Mercantile F017 Restaurant F016 Tavern G Low Hazard Industrial Units G100 Low Hazard Industrial G200 Moderate Hazard Industrial H1 Low Hazard Storage Units H100 Low Hazard Storage H2 Moderate Hazard Storage Units H200 Moderate Storage H210 Warehouse H202 Tank (Non Hazardous) Storage H3 Garage and Hangers H300 Garages and Hangers (Six Months) ``` I Hazardous Use Units I100 Hazardous Use I101 Tanks (Hazardous) ``` J Miscellaneous J100 Miscellaneous J002 Gas Station K Abandoned KO01 Abandoned L Vacant L001 Vacant M Mixed Occupancy M001 Mixed Occupancy
415
Levels of PPE:
Level A - total encapsulating, vapor proof suit with SCBA Level B - encapsulating, splash proof suit with SCBA Level C - splash proof suit with SCBA Level D - structural firefighting gear with SCBA Any incident requiring higher than Level D requires a Level II Hazmat. GO 03-004
416
What initiates a Level II response? 3 answers
1. Confirmed incident of moderate or large quantity 2. Incident requiring PPE above Level D 3. Incident requiring evacuations Isolate - Identify - Notify - Mitigate - Terminate GO 03-004
417
Rate of rise heat detectors may sound when temperature rise exceeds _____ per minute?
12 degree to 15degree change per minute -Two main types of smoke detector Photoelectric and Ionization AN Summer 2009 (Fire Alarm Systems)
418
The municipal code of Chicago requires that a zoned type fire alarm system, with zones not exceeding 20,000 square feet or serving more than one floor, shall be required under any one of the following conditions:
2 - more than 200ft long on any side 4 - building exceeds 4 stories 8 - more than 8 manual alarm sending stations 10 - more than 10 auto detectors 20 - when ground floor exceeds 20,000 sq feet AN Summer 2009 (Fire Alarm Systems)
419
All OSFM exam requests should be submitted how many days prior to the exam date?
At least 30 days prior Cert. requirements including exams must be completed within 1 year of completing course. GO 22-001
420
EMTB and EMTP License Requirements
1. OPT Out Months - March and October 2. Failure to maintain license may be placed on unpaid leave for up to 20 months. 3. Update address within 72hrs 4. If not required to maintain license notify CFD and OPSA no later than 30 days prior to expiration. GO 22-002
421
Electrical Power Outage Plan Stages
Stage 1 - not expected to last longer than 2hrs Stage 2 - greater than 2hrs but less than 8hrs (CO school/drill cancelled) Stage 3 - outage over 8hrs (variances cancelled/recall initiated) OO 05-004
422
CTA Short and Long Term Incident Times
Short Term - 30mins or less Long Term - greater than 30mins OO 08-009
423
How many Duodote dosages per riding position?
3 For treatment of organophorous and nerve agents Administer when member experiences 2 or more mild symptoms 1st dose in thigh hold for ten secs 2nd dose after 10-15mins If additional sever symptoms after first dose administer next two doses in succession no more than 3 doses Exchange through SLD if within 60 days of expiration Chiefs store in the glovebox OO 12-003
424
Barricades from Streets and Sanitation are approximately how many feet in length?
Approx 10ft OO 12-027
425
When do BC's report daily activities to DDC?
1. Arrival at district 2. 2200 hours 3. At 0600 prior to being relieved (if between 2200 and 0600) OO 17-010
426
Proper Donning of the Portable Radio Specifics
In station gear - antenna just below the belt line In bunker gear - radio strap over suspenders, top of radio case just below the hemline of bunker coat and clasp bottom 3 bluckles When entering IDLH enviroment extend RSM between 3rd and 4th buckle and secure outside. Sway straps not used in bunker gear OO 20-004
427
RAM XD Specs
Supplied by single 2 1/2 hoseline Leadout greater than 250ft, use sufficient amout on 4in and 1length of 2 1/2 OO 20-012
428
McKesson Fingertip Pulse Oximeter Notes
Apply to earlobe as alternate location Measures SPO2 of arterial hemoglobin OO 20-017
429
Multi Agency Incident Response definitions: Division
Division: A defined GEOGRAPHIC AREA at a large-scale incident (for example: North, South, Fire Building, Side B Exposure, etc.). Within the NIMS framework, a Division (geographic) is considered equal in scope to a Group (functional). SOP 601.00
430
Multi Agency Incident Response definitions: Group
Group: A defined FUNCTIONAL LEVEL of OPERATIONS at a large-scale incident (for example: Search and Rescue, Fire Attack, EMS Triage, EMS Treatment, etc.). Within the NIMS framework, a Group (functional) is considered equal in scope to a Division (geographic). SOP 601.00
431
Multi Agency Incident Response definitions: Section
Section: Any major FUNCTIONAL COMPONENT For example: Operations, Planning, Logistics, Finance/Administration, and Intelligence/Investigations) of incident management. Sections may be further subdivided into Branches, Divisions, and/or Groups. SOP 601.00
432
Multi Agency Incident Response definitions: Strike Team
Strike Team: A specified combination of the same kind and type of resource, with a leader (For example: A group of five Engine Companies and a Battalion Chief dispatched to a MABAS response). SOP 601.00
433
Multi Agency Incident Response definitions: Task Force
Task Force: A group of multiple different types of resources that may be pre-established and sent to an incident or formed at an incident (For example: A Rapid Intervention Team at a fire; combined CFD-CPD resources at Active Shooter Incidents). SOP 601.00
434
When establishing a safe perimeter and command post during a Radiation Dispersal Device incident how should it be set?
100yards beyond dust/debris feild (Larger than normal ) A Ludlum( pancake probe) radiation detection instrument may be needed for Alpha & Beta Water from 1 3/4 line if decon shower not available SB 08-005
435
How can you reduce Backdraft potential?
Top to bottom ventilation (and coordinated fire attack ) Signs of Backdraft: -"living fire" smoke puffing from building/breathing -smoke stained windows -yellow/gray smoke due to unburned sulfur -turbulent smoke, swirling SB 10-002
436
During a fire, you notice the fire building sucking smoke inward what is this phenomenon called?
Air entrainment Smoke explosions often involve a delayed reaction time usually 15sec SB 22-003
437
When conducting Tenant In-Service Inspections (TOC) how will you proceed when making the interior inspection?
With someone from the building or establishment -Fire extinguishers not required in buildings under 3000 sq ft -18inch clearance around heaters -no storage in trusses TB 1985-05
438
Name the five gases in the gas family of crude oil.
Methane, Ethane (In gas mains as a vapor known as natural gas) Propane,Isobutane,Normal Butane (known as LPG or PG) 1gallon of liquified Propane @ 60* will produce 36 cubic feet of gas TB 1986-09
439
When approaching a scene of an LPG leak and you notice a cloud of white fog, what does that indicate?
A large leak (Outer edges most flammable) Best way to keep pressure down is to cool upper part of tank Avoid the ends of the tank most likely to travel great distance in explosion Best way to break up gas vapors is with a water fog TB 1986-09
440
Whats is the vapor pressure of propane at 60 and 100 degrees.
60 degrees - 92.4lbs per square inch 100 degrees - 174.8lbs per square inch Ice or frost on a tank will be slightly higher than the level of the liquid in the tank TB 1986-09
441
What is a quick way to relieve water from the floor?
Lifting the toilet As little as 2 inches of water is an indication of possible collapse SOP @ 50lbs nozzle pressure adds approximately 1 1/2 tons of weight Master stream flowing 600gpm adds approximately 2 1/2 tons Pry up interior threshold, cut hole near jamb/poke hole in ceiling below AN Jan 2000
442
Identify the 3 school bus accident categories. (SBA)
Category I- significant injuries/significant mechanism Category II- minor injuries/no mechanism Category III- no injuries no mechanism Ranking Paramedic will report the SBA category and number of patients AN Dec 2000
443
What is considered a high pressure hydrant?
A hydrant which produces static pressure higher than than 60psi. (And as high as 200psi) Standard hydrant pressure is 30-35 psi AN Jan 2000
444
What are the procedures when supplying an engine from a high pressure hydrant?
-no hard suction -50ft of 4in to 6in gated intake -do not open intake until ready for water -switch from road to pump(do not engage the pump) -set transfer valve to Volume -blow off line required/open fully at first -engage pump if additional pressure needed AN jan 2000
445
After establishing a last scene point where are victims often found?
Within a radius of the last scene point equal to the depth of the water. AN Fall 2008
446
What are the three main components when establishing a last scene point?
-Witness interviews -using reference points -identifying physical evidence "Rescue Mode"- 60mins from the time of actual drowning CONTRADICTED BY SOP 508 AN Fall 2008 (Last Scene Point)
447
Tower Crane Specs
•Slewing unit- houses gear and motor •Working arm/JIB- carry load •Machinery arm-motors, electronics, counter weights AN Summer 2009 (Tower Cranes & Crane Collapse)
448
Whats are the five steps in the collapse rescue plan?
1.Size up and Recon 2.Rescue of surface victims 3.Void search 4.Tunnel and Trench 5.Remove rubble Eliminate vibrations within 300ft AN Summer 2009 (Tower Cranes & Crane Collapse)
449
After approximately how many seconds of user remaining motionless will the pre-alarm sound on the MSA Motion Scout?
After approx. 25secs (pre alarm will sound for 15secs) after those 15 secs Full alarm will sound. Battery-200hrs activated/10hrs in full alarm Red battery warning- full alarm time left only 1hr Temp warning- sets off at above 176 degrees/Hi-Lo tone every 2 1/2 seconds Keeper clip secured to D-ring of truckman's belt. AN April 2011
450
What NFPA code requires an over fill protection device on propane cylinders 4-40lbs?
NFPA code 58 Max ratio of liquid to vapor space is 80%liquid 20% vapor Expansion ratio of propane 270:1 (1gal liquid produces 36cubic feet of vapor at 60 degrees) Vapor density of 1.5 (heavier than air) QD April 2002
451
What is the approximate area of isolation for a LPG leak up to 100lbs?
Approximately 400ft 2 line lead out (fog to dissipate vapors and deflect radiant heat -solid stream in case of ignition to cool tank) Blue/green stain= oxidation from ammonia Isolate,identify,notify,mitigate, terminate Contact Chicago Dept. of Energy QD April 2002
452
About how far apart are steel truss roof joists spaced?
Up to 6 feet apart Primary danger for FFs is falling into hole they cut Rule of thumb failure time 10min @1000 degrees for fire service 5 mins 1/8 inch thick, 6ft wide, 20 ft long, insulating sheeting about 3 inches thick. QD April 2001
453
What are the license requirements for a vehicle less than 16,001lbs?
Class D drivers license and evaluated and certified by CFD If vehicle OVER 16,001lbs class B license and certified and evaluated by CFD QD Feb 2003
454
According to IFSTA what is the recommended minimum following distance between emergency vehicles?
300ft ( half a city block) Stopping doubles when speed is increased by 10mph from 30 to 40 mph 5mph increase decreases arrival time by 15secs QD Feb 2003
455
Approximately how much hose should be left behind pipe when the attack point is reached to lessen nozzle reaction and increase handling?
15ft (known as a tail) QD May 2003
456
Donning Face piece,protective hood & helmet with chinstrap should take about how long?
45 secs QD Feb 2004
457
After recognizing & identifying that a FF is in cardiac arrest what is the first step to be taken at an emergency scene?
Call for a Mayday & activate RIT (If in training and no RIT established activate EMS first) 3 Positions •Head-helmet,gloves,wristlets, scba,facepiece •Legs-waist-strap, bunker coat clips •Chest-harness chest straps, compressions Remove boots and pants prior to transport Multi Co Ops 22-003
458
How many inches should the corners be overlapped by when using cribbing to avoid low crush type failure?
They should overlap by 4 inches •bottom layer should be solid platform •height for square cribbing 3 times the width (3:1 ratio) •1:1 ratio for non square cribbing •2x2 cribbing least stable •when meeting a sloped component slope must be less than 5% Truck Co Ops 08-001
459
What are the steps of the Crab Technique?
1.Call a mayday 2.Actuate pass alarm 3.Stay low place arm in center of opening 4.Roll forward press leg against cover 5.Remain at anchor point with hand inside structure Can be executed i less than 2 sec. Multi Co Ops 11-001
460
Emergency Hydrant Port Steps
•check for gasket in hydrant bonnet/if non insert gasket •insert hydrant port align port key •turn port COUNTER CLOCKWISE until it stops •hand tighten bolts by turning clockwise Upon returning to quarter officer shall report inoperable hydrant to BC in still district where hydrant is located & OEMC Engine Co Ops 11-002
461
What type of fuel is used in the Honda EU 2000i generator?
Straight gas only •4 stroke engine •Red Ring in gas cap indicates Upper limit •fuel cap lever On, choke On, Engine switch on (to start) •eco throttle not used with eDraulic tool •green output indicator light indicated generator operating normally Fuel cap "off" fully Counter Clockwise Truck Co Ops 15-002
462
Millennium APR Specs (CBRN canister)l
(Chemical,biological,radiological, nuclear) CBRN canister attached to left side & turned ClockWise Negative Pressure Test-cover inlet, inhale and hold breath for 10 seconds Good For 8hrs, Only 2 hrs if CBRN agents in liquid or mist form Must have 19.5% O2 Level of contaminant must be below IDLH level Multi Co Ops 20-001
463
Millennium APR Specs (P100 filter)
Protects 99.97% against particles greater or equal to .3 microns If used or at EMS incident document in PCR and Journal for each member At least 19.5 O2 required for use Dunk and slosh for cleaning dirt and debris Multi Co Ops 20-001
464
What three nozzle tips are used on the RAM XD?
1 inch-200gpm 1 1/4 inch-400gpm (Best Nozzle specially for interior attack) 1 1/2 inch-600gpm -10 psi appliance friction loss -lead outs greater than 250 feet other than from standpipe use sufficient 4in and 1length of 2 1/2 -leave 15ft Tail behind monitor -inspect ball valve every 6 months -14 to 51 degree above horizontal -4inch never connected directly to monitor Engine Co Ops 20-001
465
Where are Hazardous material shipping documents commonly found?
•Motor vehicle-in cab or with driver •Train-in possession of a crew member •Marine vessel-a holder on the bridge •Aircraft-In possession of the Pilot Multi Co Ops 20-005
466
Number Guides(Orange pages)
-left hand safety -right hand emergency response info for fires,spills,leaks and first aid 3 sections •Potential Hazards-health and fire dangers •Public safety-safety measures, protective clothing, evac distances •Emergency Response-actions for fire and spill or leak, first aid for victims Multi Co Ops 20-005
467
What type if foam us used on foam equipped engine?
Class A foam -for class A fires(wood,paper, rubber) -attracts carbon -used between .1% & 1% (for general suppression and wash down .3% & .5% is sufficient) -never use class B in foam tanks Engine Co Ops 21-001
468
You deploy the Elkhart HF350 hydro foam nozzle if the quarter turn metering valve is IN LINE with suction hose what percentage is it set to?
6% foam mixture For 3% valve is at 90 degrees to suction hose (reminder 3x3=9) Engine Co Ops 21-001
469
What are the three common methods for applying foam?
•Roll On- foam on ground near front edge (PREFERRED METHOD) •Bank Down-directed of an object (primarily used if object obstructs spill) •Rain Down-direct foam into air above spill or fire (Primarily used for above ground tank fires) LAST RESORT method Multi Co Ops 21-001
470
If a fire situation dictates that a command post be set for a train fire, where will it be located?
Near the "customer assistance booth" on the mezzanine level (May be relocated to the communications van or the supervisors booth on the platform) CTA Manual
471
VPS DOOR REVIEW
•Original Model Number Coded -locking mechanism towards latch -numerical key pad -status indicator -vertical cut left of mechanism up to header then back to bottom of door •New Model Color coded -color coded keypad -locking mechanism at center -status indicator -cut large triangle adjacent to the center mechanism/hinge side •Skeleton Key Outward Swinging -flush no handles -2 skeleton key holes in line top & bottom -plunge cut 1in to right of key hole •Skeleton Key Inward Swinging -flush no handles -2 skeleton key holes in line top & bottom -door opening reduced -cut hinges •Rear Security Door 1st model -flush no handles -1 VPS logo middle on latch side -cut triangle 6 in from hinge even with VPS logo •Rear Security Door 2nd model -flush no handles -2 VPS logos top & bottom latch side -plunge cut 1 in to right of both VPS logo bolts -hand tools or grinder cut VPS logo bolts Truck Co Ops 10-001
472
Bowstring Truss Specs
Bowstring trusses carry loads horizontally to vertical masonry elements •curved top chord-loaded in compression •linear bottom chord- loaded in tension •angled web- tension or compression Purlins- are framing members perpendicular to and supported by truss 2 most crucial connections- •steel U-shaped shoe(found at the bearing of the truss on the masonry wall •bottom chord tension splice(connecting bottom chord members) Trusses built prior to late1960s-bottom chord members may not have tensile strength to support code prescribed roof loads •Non Immediate issues- referral to building dept(using complaint referral form) •Immediate issues-request BC AN March 2011
473
Which are most frequent type of crashes?
Frontal collision(not necessarily the most severe) Place apparatus in blocking position IDOT can be reached on Admin 3 5by 10 by 20inch Rule- •5 inch with required for side impact air bag •10 inches depth front air bag will deploy from steering wheel •20 inch depth that typical pass. side front air bag will deploy outward Disconnect NEGATIVE battery cable first(must disconnect positive also) Lay 21/2 line with Fog nozzle in accident with victims trapped and possibly fire and bring ansul AN Summer 2009 (FF Safety During Auto Extrication)
474
In what areas can the PA system in a high rise provide one way communications from FACP?
•Elevators •Elevator Lobbies •In each required stairwell every 5th floor •Office areas exceeding 5000 square feet •In corridors at a minimum of every 75 feet and at the exit stair doors AN Summer 2009 (Fire Alarm Systems)
475
What is the primary difference between Class I Fire alarm system and a class II fire alarm system?
Class I actuates ALL signaling devices. Class II activate only Pre-signal Sounding devices only( not to alert occupants but to alert those in charge to investigate) (There shall be on duty 2 adults charged with sounding the general alarm) AN Summer 2009 (Fire Alarm Systems)
476
What is a spandrel wall ?
The wall surface between the top of one window and the bottom of the window directly above it. AN Spring 2008 (Coordinated Fire Ground Ops)
477
What steps are taken when a "Non-compliant" hose tower is found?
1. Immediately have hose removed from Non-compliant hose tower 2. Report to nearest in service hose tower 3.Notify on duty officer that they will be utilizing hose tower 4.Hang hose and record in the ENGINE journal of THAT firehouse •company that hang hose •number of lengths hung •size of hose hung •individual hose number of each length hung 5.When hose is dry officer of house where hose was hung will notify officer of company who hose belongs to LO 17-001
478
When supplying the floor below pipe, to which standpipe do you hook up to?
The standpipe 2 floors below the fire floor •1 1/2 inch piping system •1 1/8 smooth bore tip •250/50 •2 1/2 hose with 1 1/4 SOP •Positioned approx 3ft from window •1 engine member operates 1 1/4 SOP •2 truck members operate floor below pipe T-bar If wind driven fire place on windward side(wind blowing in) Engineer or officer from staging to assist radio monitoring with exterior chief OO 18-006
479
How many minute scba bottle is used on the True North RIT pack?