Captain Deck Flashcards
Mourning Band Protocol
Worn straight across the center of the badge A, B or C uniform
Width of the black band should not exceed ½ inch.
Worn for a period of 30 days from the date of a CFD LODD
Optionally worn for the LODD of a neighboring jurisdiction from the date of death and removed at the conclusion of the day of burial.
GO 18-012 ❗️
How many masks are needed during a deep tunnel incident?
6 (5 plus one extra)
GO 92-005 ❗️
In the City of Chicago, Standpipe Outlets come in three types:
CLASS I
CLASS II
CLASS III
Class I, with a single 2 ½ inch male connection.
Class II, with a single 1 ½ inch male connection. This type of system is not utilized by the CFD.
Class III, with both 2 ½ inch and 1 ½ inch male connections. This is the MOST COMMON type of Standpipe Outlet found in Chicago.
SOP 210.00
CFD Forms Review:
160 - Report of Injury or Illness (layup) 159 - Return to Duty 919 - House Repair 11.202 - Damaged Hose 11.203 - Lost or Stolen Equipment 920 - Bereavement Leave PER 72 - Address Change 903 - Allegation of Violations 156 - Hose Test FORM 4 - Hydrant Inspection
Form Manual
During CO investigations, when do you notify the gas company? 4 answers
- Levels greater than 9ppm
- Any appliance turned off
- Occupants show signs of CO poisoning
- IC requests
SOP 507.07
During a stalled train, if it is determined that service will be interrupted for more than 10 minutes, sufficient life safety hazard exists to enter the train or passengers are beginning to self evacuate, what 4 actions shall be taken?
- Locate entry point( s) and approximate location( s) of train( s ).
- Request a power shutdown of the system.
- If informed that the power has been shutdown by CTA, request a secondary hold.
- Deploy the following personnel and equipment
a. Truck officer with hand-light and bullhorn (from Battalion Chief).
b. A member of the truck with forcible entry tools and hand-lights.
c. 2 Members from Engine with hand-light and portable oxygen.
d. 2 Ambulance Paramedics with QRB, portable oxygen, Lifepak 12 and stairchair.
OO 08-003
In a high rise fire, who is located 1 floor below the fire floor?
The 1st Engine (FIT engine connecting to standpipe for leadout 50, 60 70psi)
2nd Engine assisting the 1st engine
RIT staging (1bc, 1truck, 1 ALS engine - ALS chief & ambo in lobby)
SOP 210.00
How is the transport index measured for radioactive material?
The TI is measured in mR/hr at one (1) meter (3.3 feet) from the surface of the package.
SOP 511.00
Supervac V18 Fan Specs
Used for positive pressure only
Will operate for 30mins with 2 full batteries
Batteries must be above 40’ to charge and will fully recharge in 90mins.
OO 20-019
What do the following stand for in a Radiation Response with intentional devices: RDD RED RID IND
RDD-Radiological Dispersal Device (dirty bomb, wide area)
RED-Radiological Exposure Device (source usually hidden, intended for specific person)
RID-Radiological Incendiary Device (couples fire with radio active material)
IND-Improvised Nuclear Device (high levels, large area)
SOP 511.00
All vehicle types require a minimum of how many hours of drivers training.
12 hrs.
Members seeking cert must have completed 12 months in the field since academy graduation.
GO 20-006
Who does the FIT Engine notify of the adequacy of water supply from the standpipe connection?
Fire Attack Chief
If more than 200 feet of hose is needed, notify Lobby Command
CFD members are prohibited from using CFD 1 ¾-inch hose, or 1 ½- inch “house” hose lines for a high-rise fire attack.
SOP 210.00
DURING HIS TOUR OF DUTY Engineer CREEDON TELLS LT LINK HE IS VERY TIRED AND WOULD LIKE TO TAKE A NAP AFTER MORNING CHORES. DURING WHAT TIMES IS IT NOT PERMISSIBLE TO SLEEP OR LOUNGE AROUND COMPANY QUARTERS?
0700-1800HRS
GO 13-007
At approximately how many minutes of heavy fire on 2 or more floors will an ordinary constructed building become structurally unsafe?
After 20 minutes
QD Jan 2002
What are the approved visiting hours, including times for Union Reps and non-platoon duty?
0930-2100
Union Reps - 1200-1300 and 1600-2100, or 30 mins after roll call for non platoon duty
GO 00-003
In a high rise: what is the engine and truck response on: Automatic Alarm in Category 2, 3, or 4? Automatic Alarm in Category 1? Still In a High Rise? Still and Box in a High Rise?
Automatic Alarm in Category 2, 3, or 4? 1E, 1T, 1BC
Automatic Alarm in Category 1? 2E, 2T, 1BC
Still In a High Rise? 3E, 2T, 3BC, 1SQ, 1A, 1PFC, 1CV, 1DDC
Still and Box in a High Rise? 6E (including 1 ALS engine), 4T, 8 BC, 1 TL not used as RAT, ect.
SOP 210.00
Non-pressurized Ansul extinguishers must be inspected annually and hydrostatically tested every how many years?
12 years
LO 15-003
During a progress report, what does C.A.N. stand for?
C-onditions
A-ctions
N-eeds
SOP 111.00
LT WOLF OBSERVES SEVERAL DOWNED POWER LINES WHAT IS THE MINIMUM AMOUNT OF SPANS HE SHOULD ISOLATE ?
A MINIMUM OF 1 SPAN
S.O.P. 203
Is the TIC camera intrinsically safe?
NO.
QD April 2004
In addition to the Drill of the Day, Company Officers must conduct at least ____ other Company Drills and/or Company Schools during each tour of duty.
At least 2 (for a total of 3) must be entered into sharepoint by 2100
1hr hands on
1hr classroom
OO 15-002 ❗️
What defines a “master stream”?
A high-volume (minimum of 350 gallons per minute) stream delivered through a minimum 1 ¼-inch nozzle.
SOP 207.00
DURING SIZE UP LT. LINK NOTICES HEAVY FIRE FROM CHIMNEY, CRACKS IN FOUNDATION, AND FILLING FIRST FLOOR DOORWAY. WHAT IS THE MOST LIKELY LOCATION OF THE FIRE?
THE BASEMENT
A basement is defined as a story of a building partly or wholly below grade in Side A
per Multi-Co Ops 14-001
A.N. SUMMER 2004
What is the preferred method for shutting off the electricity during a fire to preserve evidence?
Shut off the main breaker
Multi Co Ops 11-003
AN Spring 2008