OPC Flashcards
Main transmission lubrication system
Wet sump
2 pumps
2 oil cooler sections
The main transmission provides output power for
Main and tail rotor
Hydraulic pumps and oil cooling fans
The main transmission oil pumps are mounted
On the bottom of the transmission
MMI limit
Amber: 54% to 66%
Red: >66%
White:100%
Engine oil pressure
Mini. 1.5 - 3.3 bar
Caution 2.25 to 4.2 bar
Max 12 - 15 bar
Engine oil temp
Mini for start -40•c
Mini for power application 0•c
Max 115•c
Main transmission monitoring and indication system comprises :
Oil pressure, temperature, contamination
Rotor RPM
Mast moment and limit monitoring
Main Transmission Temp
Min for pwr application : -10c
Max: 105 c
Eng Oil T
mini: with 3 cSt -10c (-45c for start)
with 5 cSt 0c (-30c for start)
Max : 117c
Main Transmission Oil P
Mini: 1 bar
Caution: 1 - 1.3 bar
continuous: 1.3 - 5 bar
Eng starter generator
fdg