An on an mobile gen set, model 7.5HDKAL-1C is used to power the ____ volt lighting
110 volt
The genset controls a are located in 3 locations;
1.
2.
3.
- Switch on generator
2.control box inside the left compartment
3.switches located on the dash board of tractor cab
On an model number(2003) (2006-2009) (pierce)
7.5HDKAL-1C
7.5HDKAL-1E
7.5HDKAL-1B
On an genset;
Ac volts-
KVA-
Kw-
Amps-
Hz-
RPM-
Ac volts- 120/240
KVA-7.5
Kw-7.5
Amps-31
Hz-60
RPM- 1800
Cord reel contains ___ ‘ of electrical cord with 2 ___ amp receptacles
200
20 amp
On an The electrical panel located _____. The electrical panel consists of ___ circuit breakers.
In the left compartment ;12
On an genset; keep a no load operation to a minimum . Why
Combustion chamber temperature drop to the point where the fuel does not burn completely, causing slobbering and white smoke.
When stopping the genset , let it cool down by running at no-load for ___ to ___ min
3 to 5 min
LTI Onan access -2
Pierce accessed
From the lid on top of chassis compartment
Right door on chassis compartment
Driver side rear tractor compartment
Passenger side rear mounted tractor compartment
Rear mounted access doors and floor gate
Onan used to power; x3
Lighting
Electrical outlets
Battery charger on the apparatus
Generator controls x6
Start /stop
Pre heat
Oil pressure gauge
Temperature gauge
Volts gauge
Hour meter
Genset can power x5
Air cushion fans
Submersible pump
Water vacuum
Lights
Other appliances
Cranking engine
Do not crank engine for more than ___ seconds at a time.
Wait __ minutes before attempting to start again
15; w min
06’ GLC ( generator logic control)
Depending upon how the control is set, the generator will start when either the ____ or ___
Battery voltage becomes to low, or time of day for auto start has occurred
06 GLC (Generator logic control)
Auto; Will start when batteries are below ____ volts and will run until the battery voltage has exceeded ___ volts for one hour.
When running in auto the ___ symbol will illuminate.
When starting the generator, the generator logic control will crank the generator for ___ sec and retry again after ___ sec. If after the ____ attempt the generator does not start “____” will flash on display
12.1/ 13.3
Lightning bolt
5 sec/ 5sec/ 5th attempt