Normal Procedures Flashcards
Pre-start AWG test
Hold switch, observe:
“Aural warning ok”
AWG FAIL caution message
“Rotor Low” “Engine out” “Engine Fire” “Warning” “Rotor High” “One Hundred Fifty”
Pre-start FCU/FIRE test
CAS:
AVN FAN FAIL, FUEL LOW, ENG FIRE
“Engine Fire” X2
Fuel quantity drops to zero (not below)
RH fuel “X”
If fire detection or low fuel detection fail, MCL will remain illuminated
Pre start EEC/MEC test
Cycle EEC/MEC Switch CAS: -EEC FAIL, -EEC DEGRADED, -MEC OPN
Pre- start G1000 messages to cancel flight:
GIA1 (2) COOLING OVER
TEMPERATURE
GIA1(2) SERVICE
PFD1 (MFD1) COOLING
PFD1(MFD1) SERVICE
XTALK ERROR
Min voltage for start
24V Battery
28V Cart
Min N1 for start
12% N1, 100 Deg C MAX
Idle N1 speed check after start
Normal: 61%
Cold conditions: minimum 51% ok, allow 3 min warmup, followed by additional 3 min if necessary. Afterward (6min), if N1 still below 61%, shut down
Oil temperature after start
Idle until ENG OIL TEMP = 10 Deg
Run up HYD test
Switch- NORM, Min Drop not less than 70 PSI
Check SERVO 1-2 independently, max drop 70 PSI
Tail Rotor Boost pressure- Servo 1
Run up SAS test
SAS 1-2 ON, observe CAS caution messages out
ATT HOLD -OFF observe ATT OFF CAS message displayed
check pitch, roll indicators
Set SAS 1 - OFF, check pitch, roll indicators +CAS message
Set SAS 2 - OFF, ATTD HOLD switch trips to ATTD HOLD position, + CAS message displayed
Set SAS 1-2 ON, Check CAS messages out
Max temp before opening throttle
100 Deg