NIs Flashcards
1
Q
SR
- Range
- Calibration method
- Gamma comp method
A
1 to 10^6 CPS
Inject known count rate
Pulse height discrimination
2
Q
IR
- Range
- Calibration method
- Gamma comp method
A
10^-11 to 10^-3 amps
Inject a known current
Compensated ion chamber
3
Q
PR
- Range
- Calibration method
- Gamma comp method
A
0 to 120 RTP
Calorimetric and incore
N/A - gammas a small portion and proportional to power
4
Q
Describe NI cabinet fuse types
A
Control power
Powers bistables only
Trips bistables when pulled
Drawer still has power for troubleshooting
Instrument power
Powers all electronics in the drawer
Can’t troubleshoot when pulled
5
Q
SR outputs
A
Audio
SUR
Trip at 10^5
6
Q
IR outputs
A
SUR
P6 at 10^-10
C1 at 20%
Trip at 25%
7
Q
PR outputs
A
P8 at 48% P9 at 50% P10 at 10% Trip at 25% C2 at 103% Trip at 109% Power AFD QPTR OTDT Rod control