Multiplex Systems Flashcards

1
Q

What is a condenser holdback valve for multiplex system discharge pressure regulating?

A

ORI

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Valve used for head pressure control that bypasses hot gas to the high side receiver in a multiplex system ?

A

ORD

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Why is condenser flooding an important operating requirement in low outdoor ambient conditions?

A
  • It increases the condensers capacity to reject heat

- It decreases the condensers ability to reject heat

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Where is a holdback valve for condensing pressure control installed on a multiplex system?

A

Condensate line

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the most common method of defrosting evaporators on supermarket multiplex refrigeration systems?

A

Reverse flow hot gas defrost

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the purpose of running a Satellite compressor or a dedicated Independent compressor on a multiplex refrigeration system?

A

Runs a small portion of the load at the lowest SST

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Why is a Defrost Differential Pressure Regulator between the Receiver and Liquid Header?

A

To create a difference in pressure between the defrost header and the liquid line

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

If you increase the spring tension on one EPR on a multiplex system, what changes?

A

Evaporator pressure increases

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What would cause the actuator to terminate split operation and return the summer condenser to operation?

A

OA and discharge pressure rising above a set point

How well did you know this?
1
Not at all
2
3
4
5
Perfectly