MOCK EXAM Flashcards
The no. of accounts has is determined by the no. of ___ they want to receive
Bills
___ never expire; they just become dormant when they have no active contracts
Accounts
A ___ is created for every property where service is delivered
Premise
3 components used to identify what an MC measures
UOM, TOU, SQI
Which is true:
- A dvc can have 1/more MCs over time
- A dvc can have 1/more DCs over time
- An MC can have 1/more devices over time
- A DC can have 1/more device components over time
- A dvc can have 1/more DCs over time
W/c of the ff are NOT device attributes
- Manufacturer and Model
- Serial num and badge num
- Headend system
- Channel Id
Channel Id
W/c MC type should reference a DC
Physical
4 Types of MCs
Physical, Standalone, Scratchpad and Aggregator
Which of the ff statements are TRUE about Assets and Components
- Components are not a class of assets
- Components are devices or other objects that are attached/installed on another device, usually an Asset
- Only Assets can have Specifications associated w/ them. Components can’t have Specifications associated.
- Components are devices or other objects that are attached/installed on another device, usually an Asset
An Asset’s ___ is the combination of its location and status
Disposition
Which of the ff are valid Asset Dispositions?
- Receiving, Storage Room, Repair Shop, Disposal Room
- In Receipt, Rejected, Installed, In Repair, Retired
- Pending, In Receipt, In Store, Rejected, Cancelled, Final
- In Receipt, Rejected, In Store, Installed, In Repair, Disposed
- In Receipt, Rejected, Installed, In Repair, Retired
Which of the ff are NOT true about Specifications and their relationships to Assets
- Assets and components can have Specifications associated with them to describe design details and/or functional performance criteria
- Specifications reference an Asset Type and Manufaturer
- A specification cannot be used on multiple assets.
- Specifications can include set of procedures, careful handling instructions for hazardous/delicate materials, or any other set of attributes needed to provide info about assets
- A specification cannot be used on multiple assets.
Created when a device is installed at an SP
Install Event
Which of the ff statements are NOT true about devices, SPs and Install Events
- A device may/may not be installed at an SP
- A device may be installed at diff SPs over time
- An SP can have 0, 1 or more Devices at any given time
- An SP may have different devices installed over time
- An SP can have 0, 1 or more Devices at any given time
___ represent specific requests to perform work at SPs
Service Orders
Which of the ff statements re: Measurements are TRUE?
- Interval initial measurement can contain many readings
- You can directly update a final measurement
- Scalar initial measurements only need one reading
- Final Measurements can record up to 20 derived values
- Interval initial measurement can contain many readings
- Scalar initial measurements only need one reading
How many final measurements are created for an IMD with 24 hrs of 15-minute readings?
- 1
- 24
- 48
- 96
96
3 types of IMDs
Initial Load, Manual, Estimation
Subtractive MC Usage = ___
End measurement - Start measurement
Interval MC Usage = ___
Measurement
During ___ stage, system applies register and installation multipliers
Pre-VEE
Which 2 entities can you configure VEE groups
MC Type and MC
___ must exist before a customer or SP’s usage can be calculated
Usage Subscription
Which is true about Usage Subscriptions
- US may be linked to multiple SPs at any instant in time
- US may have only one SP at any instant in time
- US are created/updated when SA is created/updated
- US are created/updated when SP is created/updated
- US may be linked to multiple SPs at any instant in time
- US are created/updated when SA is created/updated
Which is true about relationships between MCs, SPs and DCs?
- SP may be linked to multiple DCs at any instant in time
- SP may be linked to a single DC at any instant in time
- A new DC is required whenever a device’s MC are reconfigured
- A DC can have multiple MCs
- SP may be linked to a single DC at any instant in time
- A new DC is required whenever a device’s MC are reconfigured
- A DC can have multiple MCs
SA start option is used to default which of the ff?
- SA type, rate, chars, deposit amt, bill factor
- SA type, chars, contract value, contract quantity
- Rate, chars, contract rider, contract value, contract quantity, recurring charge amt
- Rate, chars, contract rider, contract value, contract quantity, billable charges
- Rate, chars, contract rider, contract value, contract quantity, recurring charge amt
What are the components and structure of a Rate?
- Rate Sched Data, Pre-processing Calc Group, Rate Version Calc Group, Post-processing Calc Group
- Rate Sched Data, Pre-processing Calc Group, Post-processing Calc Group
- Rate Sched Data, Pre-processing Calc Group, Rate Version Calc Group
- Rate Sched Data, Rate Version Calc Group, Post-processing Calc Group
- Rate Sched Data, Pre-processing Calc Group, Rate Version Calc Group, Post-processing Calc Group
A rate’s ___ controls the proration of time-dependent prices
Frequency
Which of the ff can cause price proration?
- Multiple rate versions in effect during a bill period
- Bill Factor value changes during bill period
- Both A and B
- Neither A nor B
- Both A and B
Where can you enable, disable or override proration?
- Rate Sched
- Bill Factor
- Calc Rule BO
- All of the above
- All of the above
What can cause multiple bill lines for a rate component in a bill header?
- Change in Rate Sched in a bill period
- Change in Rate Version in a bill period
- Multiple Bill Factor values in a bill period
- None of the above
- Change in Rate Version in a bill period
- Multiple Bill Factor values in a bill period
___ are transformed measurements that are exported to another system (2)
Final Measurements and Usage Transactions
Which base package Usage Calc Rule do you use to retrieve measurements for scalar MCs
Get Scalar Details
Which of the ff statements are TRUE about FTs?
- User can create FT directly
- FT is created by the system when SA is billed, paid or adjusted
- FT is deleted when bseg, pay segment or adjustment is cancelled
- New reversion FT is created when a bseg, pay segment or adjustment is cancelled
- FT is created by the system when SA is billed, paid or adjusted
- New reversion FT is created when a bseg, pay segment or adjustment is cancelled
Which of the ff is NOT controlled by the Adjustment Type
- If its adjustments should print on bills
- How adjustment appears on printed bill
- Valid SA Types for the adjustments
- If adjustment requires approval
- Valid SA Types for the adjustments
Which of the ff statements about Payments are FALSE?
- When you cancel a payment tender, the system cancels ALL payments linked to the payment event
- When you cancel a payment, payment tenders are NOT cancelled
- Payment Event can have multiple tenders depending on the type of payment (e.g. cash, check)
- When a payment is cancelled, payment FT is deleted
- When a payment is cancelled, payment FT is deleted
Collection process collects on SAs with the same ___
Debt Class