Miscellaneous Other Flashcards
Corrosion – pH level that causes corrosion to increase
Corrosion – Chloride level where pitting on steel begins
10 ppm
NDE - Weight used to check magnetic strength of an AC yoke
10 lb
Grounding - Maximum electrical resistance permitted from tank to earth
25 ohm
NDE – Min angle of eye-to-part to count as a Visual Exam
30 degrees
NDE - Weight used to check magnetic strength of a DC yoke
40 lb
NDE - Minimum light intensity when performing non- fluorescent MT or PT exams
100 ft-candles
Vacuum Box - Minimum light intensity when performing vacuum testing
100 ft-candles
NDE - Minimum black light intensity when performing fluorescent MT or PT exams
1000 micro- W/cm2
Brittle – Shell stress when brittle fracture is NOT a concern
NDE - Hole size that must be visible in RT when using a hole- type IQI
2T
Weld Qualification - Maximum allowed thickness on a WPS based on the plate thickness (T) of a PQR test coupon
2T
Weld Qualification – The “all-position” test coupon
6G
NDE - Lead letter used during RT to check for backscatter radiation
B
NDE - Lead letter used during RT to indicate a film-side IQI
F