Misc Equipment Flashcards
Leica DISTRO D330i is programmed to measure from the back of the unit? T/F
True
Correct Menu settings for the Lumix Point and Shoot Camera Menu are?
5M (Picture Size), Fine (Quality), and LED Light Off (Motion Picture menu).
Lumix Point and Shoot Camera Low-Light Procedure is:
Tripod required, SCN on dial, Starry Sky with cursor, select either 30 or 60 seconds.
FLIR i60 can be used as a digital camera? T/F
True (Select Digital Camera under Menu).
FLIR i60 is set to the following defaults by the technician:
Camera: Infrared
Measurement: Temperature
Color palette: Iron
Settings: F, 24h, High, and 32-662 (Temperature range)
360 Camera System setting are:
Manual Exposure (M), Large Image (L), White Balance on Auto (A), Focus Mode Switch to Manual (M)
The Focus Mode Switch on the 360 Camera System is located near the display? T/F
F- Camera front by the lens.
To set the exposure on the 360 Camera System rotate the _____ ____ while observing the exposure scale in either the ________ _________ or Viewfinder.
Control Dial; Control Panel; Viewfinder
PTGui Pro software requires the lens type to be set to ___ ____ and Field of View to ___degrees.
Circular Fisheye; 185
The proper format for the file produced by PTGui Pro software is ______ __ ___.
Quicktime VR (.mov)
The MiniMIRAIII detects what signals on MULTIBAND?
Microwave (S, C, X, & K), Ultrasonic (U)
WIFI can cause false signals on which two bands on the MIRA?
S and C
On the MIRA, X and K may falsely indicate positive due to?
Police Radar
EMR Detector batteries are installed with the positive terminal toward the front of unit? T/F
True
To calibrate the EMR Detector, the unit is placed between the Item of Interest and other potential EMR sources, then turned on. After verifying lamp test, ensure the orange/blue “Heartbeat” LED pulses every _ seconds. Ensure detector enters “Calibration” mode lasting ____ seconds and ending with rapid ___-tone pulse.
2; 10; 4.
Suggested rate of scan with the EMR Detector after locating a source is _ in/sec.
2
On the Mini MIRAIII pressing the letter button on the left does what?
Enters Single Band Mode for the selected band.
On the Mini MIRAIII pressing the speaker button on the right does what?
Disables audio indicator for selected band.
The 2 LED’s on top of the IR Wand handle indicate what?
One for each side of wand; Color indicates signal strength (green, amber, and red); Indicates direction of transmitter.
How do you adjust screen brightness on the MiniMIRAIII?
Press and hold center of MULTI BAND or SINGLE BAND screens and a slider bar will appear; Continue to press screen and slide your finger up or down to adjust brightness.
The Peep Sight should be placed no closer than _ foot in front of the Grid Aim board?
1 foot
The Stingray requires _ of water with the SiC packet or _ of water without the SiC packet.
1 liter, 1.4 liters.
The Peep Sight can be placed closer the 1 foot to the Grid Aim board if necessary. T/F
True (8 inches)
More than one length of hose maybe used between the water pressurized water source and the eductor. T/F
True
How many lengths of hose can be added to the outlet of the eductor?
2.
Angus Foaming requires the eductor knob to be set at _% not __% __?
6, 6 AR.
The maximum IPC size that fits under the 8 foot Cube is x_x?
4’,4’,5’.
Gelled Water Blocks weight __lbs when filled?
40.
The software used to create stitch 360 photos is ____?
PTGui
The Ricoh 360 camera can be used in low light? T/F
False, the Nikon camera must be used.
The PSI required at the nozzle to achieve foam is?
35psi
MIRA stands for?
Microwave, Infrared, and Acoustic
The MIRA handheld unit detects ________ and ______.
Microwave; Acoustic
The MIRA wand detects ______.
Infrared and can indicated the direction of the transmitter.
The EMR detector alarms by ____, ____, and ____ LEDs accompanied by audio of varying ____ and ______.
Gren, Amber, Red; Speed, Intensity
_____ non-linear reference points are seletected prior to the target when using Grid Aim.
5
To verifiy Grid Aim target: XTK>Help>View Grid Board Map. T/F
True
Do not use the vector adjustment on the tripod when aiming Grid Aim. T/F
True
The Gimble Laser and copper hemisphere are used in precision targeting. T/F
True
The Non-Newtonian fluid does what to Stingray velocity?
Slows
The fastest smooth bore projectile for the PAN is?
X9