Why are the H2 coolers on the 176 foot of the turbine building cracked open?

A

Keep air out since it is the system high point

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

At what pressure does the standby TCW pump start at?

A

55 psig on the header

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What indications do you expect on the TCW surge tank?

A
  • Level approx. 46-51”

- N2 pressure around 25-30 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is normal instrument air header pressure?

A

115 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

When do we get a low IA header pressure alarm?

A

95 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When does the backup N2 align to the IA header?

A

At approx 85 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What cools the IA compressors and service air compressor?

A

TCW

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

If TCW is out, what can cool the IA/SA compressors?

A

DS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is the H2 storage bank normally maintained at?

A

Around 2300 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

When do we get a low H2 storage bank pressure alarm?

A

200 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

When does the emergency seal oil pump auto start?

A

At approx. 110 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

How much does H2 purity degrade when we lose a main generator seal oil vacuum pump?

A

around 2% every 8 hours. Air will continually be absorbed by the seal oil system, migrating through the H2 seal and degrading H2 purity.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

In all three units which condenser shell expansion joints are wet?

A

Only unit 3’s ‘B’ expansion joint

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

At what pressure is the H2 maintained in the Generator at?

A

75 psig. You can see it on rounds by the seal oil skid.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

How is seal oil maintained in regards to H2?

A

Around 8 psig greater than H2 pressure.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is the normal pressure in the seal oil tank?

A

26-27” Hg vac

17
Q

What is normal stator cooling winding flow? When is the alarm? Trip?

A

Normal- 645-677 gpm
Alarm- 581 gpm
Trip- 549 gpm

18
Q

What is the normal pressure for the main seal oil pump?

A

around 250 psig

19
Q

What is the normal pressure for the Main Turbine LO cooler inlet bearing header pressure?

A

48 psig

20
Q

What is the normal MTLO temperature when we are running?

A

110-120 degrees F

21
Q

When do we use the 15 gpm or 30 gpm setting on the MTLO conditioner?

A

Below 100 degrees F- 15 gpm

Above 100 degrees F- 30 gpm

22
Q

What is the normal main shaft oil pump suction pressure?

A

25 psig

23
Q

What is the normal Bearing header pressure?

A

25 psig

24
Q

What is the normal Operating oil pressure?

A

225 psig

25
Q

If a critical steam trap is out of service; how often do we need to blow it down?

A

once every 6 hours

26
Q

What are the critical steam traps?

A

M23 and M24

27
Q

What is normal TCW pump discharge pressure?

A

95-115 psig

28
Q

When walking around transformers; what are you generally checking for?

A
  • oil leaks
  • Unusual noises or odors
  • Cooling coils/fans for blockage
  • Bushings chipped or cracked
  • Bushing oil levels
  • N2 Pressures
  • Sevron panel status
  • Gas analyzer status
  • Annunciator panel check
  • Oil temperatures
  • Mechanical relief device