MID-RISE TM Flashcards

1
Q

Which supply methods should the WSGS consider for a Blitz and or/ Short Attack?

A

forward, reverse, maximizing hydrant, relay pumps

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

WSGS shall advise ___ when a secured water supply has been established.

A

Fire Attack units

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Consideration should be given to supplying the FDC for the sprinkler system if ____.

A

attack method other than standpipe is used.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

what is usually the best way to shut down the sprinkler system water supply?

A

cut-off valve for branch line

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Fire personnel assigned to check the operational readiness of the fire pump should do so and report their findings to ____.
In any event of valve closure, ____ shall be notified.
If the pump does not start, notify ____.

A

WSGS

Command

Command

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Determination of Attack Stairwell is based on ___ and ____.

Stairwell used for Evacuation should be chosen based on ___ and ___.

A

location of fire and ability of hose to reach from the SP

Travel distance and smoke conditions

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Evac Group is responsible for evac of occupants where?

A

on and above fire floor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Evacuate of CO levels of ___.

A

25 ppm or higher

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

size-up of conditions found above the fire floor should be conveyed by ___ to ___.

A

Evac Group to Command

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The captain of the ___ on a major working mid-rise will be more of a ___ than a company officer.

A

2nd aerial/rescue

group supervisor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

how many additional companies should evac group supervisor request from command?

A

possibly one additional company per 2-3 floors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Vent tactics for both ___ and ___ may be used at a mid-rise.

A

single-family and high-rise

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Vent Group may open bulkheads above stairwells if conditions indicate, such as ___ or ___. Opening of bulkheads should be coordinated with ____.

A

top floor fires

smoke-charged stairwell

Evac Group

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

It is important that ___ and/or ___ be informed of smoke conditions and plans for removal.

A

Div X and/or Command

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Vent Group should check the ___ and ___ immediately, and then ___ and work down.

A

fire floor and floor above

top floor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Breaking of windows will be incident driven and communication with ____ should be undertaken prior.

A

Inside Truck, Div X, and/or Command

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

How should stairwell pressurization work?

A

one fan at a 1st floor entrance of sufficient size. if available use two in V-pattern tilted 5-15 degrees and aimed to center of doorway. if conditions don’t atleast stabilize, then but another fan in hallway 3 floors below fire, 4-6 ft from door.

18
Q

consider providing ___ if using fans to supplement stairwells above grade.

A

fresh air inlet

19
Q

wind-driven fire happens when an opposing wind of ____ mph blows into a fire compartment window. Within seconds temperatures can ___.

A

15-20 mph

double

20
Q

can stairwell pressurization stop the flow of gasses from wind-driven fires?

A

not likely

21
Q

In a wind-driven fire, if the fire room door is closed and there are no life safety concerns, do not ___. what if there are life safety concerns?

A

enter the fire floor

attempt wall breach from adjacent apartment as opposed to hallway

22
Q

What other tactical assignments should command make, as dictated by the incident?

A

RIC
Back-up: may be FA2 if not needed by FA1
Salvage Group

23
Q

personnel operating outside the structure should wear ___ as minimum ppe.

A

helmets

24
Q

mid-rise alarms are blend of ___, ___, and ___.

A

traditional Box, Commercial, and High-Rise

25
Q

Older mid-rise office buildings are often which construction type?

A

I, II, or III

26
Q

2012 IBC allows ____ story wood-frame structures of one level of typically Type ___. called ___ or ___ design.

A

5 or 6
1A
podium or pedestal

27
Q

5-over-1 and 6-over-1 buildings are treated by code as two structures separated by ___.

A

3-hour fire resistance-rated horizontal assemby

28
Q

radio reports should be given at what locations?

A
  1. exterior upon arrival
  2. interior
  3. fire floor
  4. fire apartment
29
Q

during which radio report should stairwell conditions be noted?

A

interior

30
Q

exterior size-up should include:

A

stories, fire/smoke showing, occupancy type

31
Q

Fire Attack options include:

A

Blitz, Short Attack, SP Ops

32
Q

What will send the entire building/zone into general alarm?

A

smoke/heat detector activation in common area or retail space, automatic sprinkler activation, manual pull station

33
Q

where might a pull-station be located at a mid-rise?

A

near a fire protection feature like control panel or pump room if applicable

34
Q

what factors may make a blitz attack advantageous?

A

self-vented
floor height
wind-speed

35
Q

what type of stream should be used for handline blitz? what size hoseline?

A

straight or smooth bore

strongly consider 2.5”

36
Q

who should be informed when water streams are being directed into the building from the exterior?

A

all interior companies

37
Q

two advantages of choosing an adjacent apartment for short attack:

A

layout

area of refuge

38
Q

main disadvantage of short attack:

A

personnel entering fire floor without protection of stairwell

39
Q

when conducting a short attack, what should be done before entering the hallway?

A

size-up for wind-driven conditions

40
Q

if conducting fire attack using stanpipes, who will do a quick assessment of conditions on the fire floor?

A

Inside Truck and FA1

FA2 waits on floor below

41
Q

When must the Standpipe Control Position and OTM be on full PPE and on air?

A

when hallway standpipe connection is used

*last resort

42
Q

standpipe control position should confirm with ___ that pressure is set.

A

Fire Attack Officer