MID-RISE TM Flashcards

1
Q

Which supply methods should the WSGS consider for a Blitz and or/ Short Attack?

A

forward, reverse, maximizing hydrant, relay pumps

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

WSGS shall advise ___ when a secured water supply has been established.

A

Fire Attack units

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Consideration should be given to supplying the FDC for the sprinkler system if ____.

A

attack method other than standpipe is used.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

what is usually the best way to shut down the sprinkler system water supply?

A

cut-off valve for branch line

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Fire personnel assigned to check the operational readiness of the fire pump should do so and report their findings to ____.
In any event of valve closure, ____ shall be notified.
If the pump does not start, notify ____.

A

WSGS

Command

Command

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Determination of Attack Stairwell is based on ___ and ____.

Stairwell used for Evacuation should be chosen based on ___ and ___.

A

location of fire and ability of hose to reach from the SP

Travel distance and smoke conditions

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Evac Group is responsible for evac of occupants where?

A

on and above fire floor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Evacuate of CO levels of ___.

A

25 ppm or higher

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

size-up of conditions found above the fire floor should be conveyed by ___ to ___.

A

Evac Group to Command

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The captain of the ___ on a major working mid-rise will be more of a ___ than a company officer.

A

2nd aerial/rescue

group supervisor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

how many additional companies should evac group supervisor request from command?

A

possibly one additional company per 2-3 floors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Vent tactics for both ___ and ___ may be used at a mid-rise.

A

single-family and high-rise

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Vent Group may open bulkheads above stairwells if conditions indicate, such as ___ or ___. Opening of bulkheads should be coordinated with ____.

A

top floor fires

smoke-charged stairwell

Evac Group

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

It is important that ___ and/or ___ be informed of smoke conditions and plans for removal.

A

Div X and/or Command

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Vent Group should check the ___ and ___ immediately, and then ___ and work down.

A

fire floor and floor above

top floor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Breaking of windows will be incident driven and communication with ____ should be undertaken prior.

A

Inside Truck, Div X, and/or Command

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

How should stairwell pressurization work?

A

one fan at a 1st floor entrance of sufficient size. if available use two in V-pattern tilted 5-15 degrees and aimed to center of doorway. if conditions don’t atleast stabilize, then but another fan in hallway 3 floors below fire, 4-6 ft from door.

18
Q

consider providing ___ if using fans to supplement stairwells above grade.

A

fresh air inlet

19
Q

wind-driven fire happens when an opposing wind of ____ mph blows into a fire compartment window. Within seconds temperatures can ___.

A

15-20 mph

double

20
Q

can stairwell pressurization stop the flow of gasses from wind-driven fires?

A

not likely

21
Q

In a wind-driven fire, if the fire room door is closed and there are no life safety concerns, do not ___. what if there are life safety concerns?

A

enter the fire floor

attempt wall breach from adjacent apartment as opposed to hallway

22
Q

What other tactical assignments should command make, as dictated by the incident?

A

RIC
Back-up: may be FA2 if not needed by FA1
Salvage Group

23
Q

personnel operating outside the structure should wear ___ as minimum ppe.

24
Q

mid-rise alarms are blend of ___, ___, and ___.

A

traditional Box, Commercial, and High-Rise

25
Older mid-rise office buildings are often which construction type?
I, II, or III
26
2012 IBC allows ____ story wood-frame structures of one level of typically Type ___. called ___ or ___ design.
5 or 6 1A podium or pedestal
27
5-over-1 and 6-over-1 buildings are treated by code as two structures separated by ___.
3-hour fire resistance-rated horizontal assemby
28
radio reports should be given at what locations?
1. exterior upon arrival 2. interior 3. fire floor 4. fire apartment
29
during which radio report should stairwell conditions be noted?
interior
30
exterior size-up should include:
stories, fire/smoke showing, occupancy type
31
Fire Attack options include:
Blitz, Short Attack, SP Ops
32
What will send the entire building/zone into general alarm?
smoke/heat detector activation in common area or retail space, automatic sprinkler activation, manual pull station
33
where might a pull-station be located at a mid-rise?
near a fire protection feature like control panel or pump room if applicable
34
what factors may make a blitz attack advantageous?
self-vented floor height wind-speed
35
what type of stream should be used for handline blitz? what size hoseline?
straight or smooth bore | strongly consider 2.5"
36
who should be informed when water streams are being directed into the building from the exterior?
all interior companies
37
two advantages of choosing an adjacent apartment for short attack:
layout | area of refuge
38
main disadvantage of short attack:
personnel entering fire floor without protection of stairwell
39
when conducting a short attack, what should be done before entering the hallway?
size-up for wind-driven conditions
40
if conducting fire attack using stanpipes, who will do a quick assessment of conditions on the fire floor?
Inside Truck and FA1 | FA2 waits on floor below
41
When must the Standpipe Control Position and OTM be on full PPE and on air?
when hallway standpipe connection is used | *last resort
42
standpipe control position should confirm with ___ that pressure is set.
Fire Attack Officer