Which supply methods should the WSGS consider for a Blitz and or/ Short Attack?
forward, reverse, maximizing hydrant, relay pumps
WSGS shall advise ___ when a secured water supply has been established.
Fire Attack units
Consideration should be given to supplying the FDC for the sprinkler system if ____.
attack method other than standpipe is used.
what is usually the best way to shut down the sprinkler system water supply?
cut-off valve for branch line
Fire personnel assigned to check the operational readiness of the fire pump should do so and report their findings to ____.
In any event of valve closure, ____ shall be notified.
If the pump does not start, notify ____.
WSGS
Command
Command
Determination of Attack Stairwell is based on ___ and ____.
Stairwell used for Evacuation should be chosen based on ___ and ___.
location of fire and ability of hose to reach from the SP
Travel distance and smoke conditions
Evac Group is responsible for evac of occupants where?
on and above fire floor
Evacuate of CO levels of ___.
25 ppm or higher
size-up of conditions found above the fire floor should be conveyed by ___ to ___.
Evac Group to Command
The captain of the ___ on a major working mid-rise will be more of a ___ than a company officer.
2nd aerial/rescue
group supervisor
how many additional companies should evac group supervisor request from command?
possibly one additional company per 2-3 floors
Vent tactics for both ___ and ___ may be used at a mid-rise.
single-family and high-rise
Vent Group may open bulkheads above stairwells if conditions indicate, such as ___ or ___. Opening of bulkheads should be coordinated with ____.
top floor fires
smoke-charged stairwell
Evac Group
It is important that ___ and/or ___ be informed of smoke conditions and plans for removal.
Div X and/or Command
Vent Group should check the ___ and ___ immediately, and then ___ and work down.
fire floor and floor above
top floor
Breaking of windows will be incident driven and communication with ____ should be undertaken prior.
Inside Truck, Div X, and/or Command
How should stairwell pressurization work?
one fan at a 1st floor entrance of sufficient size. if available use two in V-pattern tilted 5-15 degrees and aimed to center of doorway. if conditions don’t atleast stabilize, then but another fan in hallway 3 floors below fire, 4-6 ft from door.
consider providing ___ if using fans to supplement stairwells above grade.
fresh air inlet
wind-driven fire happens when an opposing wind of ____ mph blows into a fire compartment window. Within seconds temperatures can ___.
15-20 mph
double
can stairwell pressurization stop the flow of gasses from wind-driven fires?
not likely
In a wind-driven fire, if the fire room door is closed and there are no life safety concerns, do not ___. what if there are life safety concerns?
enter the fire floor
attempt wall breach from adjacent apartment as opposed to hallway
What other tactical assignments should command make, as dictated by the incident?
RIC
Back-up: may be FA2 if not needed by FA1
Salvage Group
personnel operating outside the structure should wear ___ as minimum ppe.
helmets
mid-rise alarms are blend of ___, ___, and ___.
traditional Box, Commercial, and High-Rise