METRO SERVICES Flashcards
Passenger stations are constructed of non-combustible materials with a fire resistance rating of at least ______.
A. 1 hour
B. 2 hours
C. 3 hours
D. 4 hours
B. 2 hours
Passenger stations are constructed of non-combustible materials with a fire resistance rating of at least 2 Hours
Station platforms are made of red and brown Terrazzo tile. The last __ inches of the platform closest to the track bed includes a __ inch bumpy Terrazzo tile surface and an __ inch granite surface.
Station platforms are made of red and brown Terrazzo tile. The last 42 inches of the platform closest to the track bed includes a 24 inch bumpy Terrazzo tile surface and an 18 inch granite surface.
Most subway stations are approximately __ feet wide with ___ foot long platform capable of handling an __ car train. They vary in height from __ to __ feet above the track surface.
Most subway stations are approximately 60 feet wide with 600 foot long platform capable of handling an eight car train. They vary in height from 30 to 35 feet above the track surface.
The _________ level is where the fare card machines and the faregates are located
A. Entrance level
B. Mezzanine level
C. Platform level
B. Mezzanine
The farecard machines is also where the demarcation between “_____” and “______” occurs.
The farecard machines is also where the demarcation between “free” and “revenue” occurs.
Kiosks are located near the _______.
Kiosks are located near the faregates
The kiosk is approximately __feet across and is ________ in shape.
The kiosk is approximately 9 feet across and is octagonal in shape.
True or false
The kiosk is a suitable command post
TRUE
On the platform level Emergency Trip Stations (ETS) are located __________.
On the platform level emergency trip stations are located at each end of the station platform.
Passenger Emergency Reporting System (PERS) are located along the station platforms. These communication devices allow immediate contact with the _______, and the kiosk when the red button is pushed.
Passenger Emergency Reporting System (PERS) are located along the station platforms. These communication devices allow immediate contact with the station manager, and the kiosk when the red button is pushed.
Standpipe access can also be made at the end of the platforms in the _________.
Standpipe access can also be made at the end of the platforms in the red equipment cabinets, where installed and on the floors covered by manhole covers every 200’
__________ are considered the primary means of emergency evacuation.
A. Elevators
B. Escalators
C. Fan Shafts
D. Vent Shafts
B.
Escalators are considered the primary means of emergency evacuation.
Should the heat or smoke alarms activate and not be reset the fair gates will lock in the open position after _______
A. 30 Seconds
B. 60 Seconds
C. 90 Seconds
D. 2 minutes
A. 30 Seconds
Should the heat or smoke alarms activate and not be reset the fair gates will lock in the open position after 30 seconds
The elevators and you said metro stations are primarily intended for the movement of handicap persons from ____________ to the ___________ and then the ___________
The elevators and you said metro stations are primarily intended for the movement of handicap persons from the street level to the mezzanine and then the platform level
True or false
Electro hydraulic elevators used in the metro system normally travel short distances
TRUE
To access the elevator machine room use the metro key ring. The ________ will open the door.
Master Key
True or false
The station manager will attempt to free trap passengers on a elevator prior to the arrival of fire rest units
TURE
The first step in trying to free passengers from a trapped elevator is ?
Locate the appropriate elevator machine room. Shut the main electrical power down and wait 15 to 20 seconds. Restore power to the elevator and some cases this may free a stocker overheated relay and restore the elevator to normal operations.
On a electric traction elevator, the counterweight system is ____ greater than the weight of the car and it’s expected maximum load.
On a electric traction elevator, the counterweight system is 40% greater than the weight of the car and it’s expected maximum load.
In the elevator machine room to communicate during elevator emergencies, you must use the ________ located in the elevator machine room
In the elevator machine room to communicate during elevator emergencies, you must use the PABX phone located in the elevator machine room
True or false
No direct communication with the elevator is available from the elevator machine room.
TRUE
_________ are the primary means of entry to and exit from metro stations
Escalators are the primary means of entry to and exit from metro stations
Escalator keys are on the Metro key ring which are located in every stations Knox box. They will have “ESC” marked on the key for identification.
Escalator keys are on the ________ which are located in every stations Knox box. They will have “___” marked on the key for identification.
The majority of injuries involving the escalators come from _____, or passengers being caught in the _________
The majority of injuries involving the escalators come from Falls, or passengers being caught in the step components
Most of the escalators used in the metric system are of ________ design
Most of the escalators used in the metric system are of modular design
The average width of escalators is __ inches and they rise at an incline of __° . The normal speed of escalators is approximately _______ per minute
The average width of escalators is 40 inches and they rise at an incline of 30° . The normal speed of escalators is approximately 90 feet per minute
Embarkation lights are located at the top and bottom of the escalators where the steps flatten out within _________of the plate. The lights are located beneath the steps and are __________ in color.
Embarkation lights are located at the top and bottom of the escalators where the steps flatten out within 16 inches of the plate. The lights are located beneath the steps and are greenish yellow in color.
Single access stations those with only one set of escalators to access the station, have an automatic fire suppression system,”_____________” system installed in the escalator pan beneath the support truss
Single access stations those with only one set of escalators to access the station, have an automatic fire suppression system,”Deluge Sprinkler” system installed in the escalator pan beneath the support truss
The sprinkler shut off controls for as escalator are located in the ___________.
The sprinkler shut off controls for as escalator are located in the escalator pit
True or False
There are no escalators shut down buttons in the kiosk
TRUE
The two methods of emergency stop for an escalator are
1. depress the emergency stop button
2. utilize the escalator key on the key ring
The Right of Way can be best described as the areas __________________________.
The Right of Way can be best described as the areas between the fences and tunnel walls where the track bed is located
Track beds consist of _________ or _______ and ______
Track beds consist of concrete or ballast and ties
The running rails used by metro are continuous welded steel rail. They also act as the _________ return for the electrical traction power system.
The running rails used by metro are continuous welded steel rail. They also act as the negative return for the electrical traction power system.
A chain marker is located every _____ feet along the line. Measurements start from a__________ or a______ of the line.
A chain marker is located every 100 feet along the line. Measurements start from a centerpoint or a hub of the line.
On a chain marker the first letter is used to identify the ________
On a chain marker the first letter is used to identify the route
On a chain marker the second number is used to identify the ___________
On a chain marker the second number is used to identify the track number (inbound or outbound)
ETS boxes are located about every ____ feet in the tunnels
ETS boxes are located about every 800 feet in the tunnels
Danger high voltage signs are located approximately every ____ feet along the right away on fences and gates to provide warning of electrical hazard
Danger high voltage signs are located approximately every 250 feet along the right away on fences and gates to provide warning of electrical hazard
No clearance signs will appear every __ feet in the areas of no clearance
No clearance signs will appear every 50 feet in the areas of no clearance
The three types of below grade tunnels are _______,_________, and_____ (cut and cover)
The three types of below grade tunnels are circular, horseshoe, and box (cut and cover)