Passenger stations are constructed of non-combustible materials with a fire resistance rating of at least ______.
A. 1 hour
B. 2 hours
C. 3 hours
D. 4 hours
B. 2 hours
Passenger stations are constructed of non-combustible materials with a fire resistance rating of at least 2 Hours
Station platforms are made of red and brown Terrazzo tile. The last __ inches of the platform closest to the track bed includes a __ inch bumpy Terrazzo tile surface and an __ inch granite surface.
Station platforms are made of red and brown Terrazzo tile. The last 42 inches of the platform closest to the track bed includes a 24 inch bumpy Terrazzo tile surface and an 18 inch granite surface.
Most subway stations are approximately __ feet wide with ___ foot long platform capable of handling an __ car train. They vary in height from __ to __ feet above the track surface.
Most subway stations are approximately 60 feet wide with 600 foot long platform capable of handling an eight car train. They vary in height from 30 to 35 feet above the track surface.
The _________ level is where the fare card machines and the faregates are located
A. Entrance level
B. Mezzanine level
C. Platform level
B. Mezzanine
The farecard machines is also where the demarcation between “_____” and “______” occurs.
The farecard machines is also where the demarcation between “free” and “revenue” occurs.
Kiosks are located near the _______.
Kiosks are located near the faregates
The kiosk is approximately __feet across and is ________ in shape.
The kiosk is approximately 9 feet across and is octagonal in shape.
True or false
The kiosk is a suitable command post
TRUE
On the platform level Emergency Trip Stations (ETS) are located __________.
On the platform level emergency trip stations are located at each end of the station platform.
Passenger Emergency Reporting System (PERS) are located along the station platforms. These communication devices allow immediate contact with the _______, and the kiosk when the red button is pushed.
Passenger Emergency Reporting System (PERS) are located along the station platforms. These communication devices allow immediate contact with the station manager, and the kiosk when the red button is pushed.
Standpipe access can also be made at the end of the platforms in the _________.
Standpipe access can also be made at the end of the platforms in the red equipment cabinets, where installed and on the floors covered by manhole covers every 200’
__________ are considered the primary means of emergency evacuation.
A. Elevators
B. Escalators
C. Fan Shafts
D. Vent Shafts
B.
Escalators are considered the primary means of emergency evacuation.
Should the heat or smoke alarms activate and not be reset the fair gates will lock in the open position after _______
A. 30 Seconds
B. 60 Seconds
C. 90 Seconds
D. 2 minutes
A. 30 Seconds
Should the heat or smoke alarms activate and not be reset the fair gates will lock in the open position after 30 seconds
The elevators and you said metro stations are primarily intended for the movement of handicap persons from ____________ to the ___________ and then the ___________
The elevators and you said metro stations are primarily intended for the movement of handicap persons from the street level to the mezzanine and then the platform level
True or false
Electro hydraulic elevators used in the metro system normally travel short distances
TRUE
To access the elevator machine room use the metro key ring. The ________ will open the door.
Master Key
True or false
The station manager will attempt to free trap passengers on a elevator prior to the arrival of fire rest units
TURE
The first step in trying to free passengers from a trapped elevator is ?
Locate the appropriate elevator machine room. Shut the main electrical power down and wait 15 to 20 seconds. Restore power to the elevator and some cases this may free a stocker overheated relay and restore the elevator to normal operations.
On a electric traction elevator, the counterweight system is ____ greater than the weight of the car and it’s expected maximum load.
On a electric traction elevator, the counterweight system is 40% greater than the weight of the car and it’s expected maximum load.
In the elevator machine room to communicate during elevator emergencies, you must use the ________ located in the elevator machine room
In the elevator machine room to communicate during elevator emergencies, you must use the PABX phone located in the elevator machine room
True or false
No direct communication with the elevator is available from the elevator machine room.
TRUE
_________ are the primary means of entry to and exit from metro stations
Escalators are the primary means of entry to and exit from metro stations
Escalator keys are on the Metro key ring which are located in every stations Knox box. They will have “ESC” marked on the key for identification.
Escalator keys are on the ________ which are located in every stations Knox box. They will have “___” marked on the key for identification.
The majority of injuries involving the escalators come from _____, or passengers being caught in the _________
The majority of injuries involving the escalators come from Falls, or passengers being caught in the step components