Memoty Items Flashcards

1
Q

EPGWS WARNING

A

“PULL UP TOGA”

AP - OFF
Pitch - PULL UP
Thrust Levers - TOGA 
Speed Brakes - CHECK RETRACTED 
Bank - WINGS LEVEL or adjust
DO NOT CHANGE CONFIGURATION - slats/flaps/gear until clear of obstacle
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

EMERGENCY DESCENT

A

“EMERGENCY DSCENT”

Crew Oxygen Masks - USE
Signs - ON
Emergency Descent - INITIATE 
Thrust Levers - IDLE
SPD Brake - FULL
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

LOSS OF BRAKING

A

“LOSS OF BRAKING”

Reversers - MAX
Brake Pedals - RELEASE 
A/SKID Off - ORDER 
A/skid & NW STRG - OFF
Brake Pedals - PRESS
Max BRK pressure - 1,000psi

If still no brake pressure - PARK BRAKE - USE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

TCAS RA

A

“TCAS I HAVE CONTROL”

AP - OFF
Both FDs - OFF
ATC - NOTIFY

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

UNRELIABLE SPEED

A

“UNRELIABLE SPEED”
•AP …………………………………………..OFF
• A/THR……………………………………..OFF
PITCH/THRUST:
- Below THRUST RED ALT ………………15/TOGA
- Above THRUST RED ALT & Below FL100 …10/CLB
- Above THRUST RED ALT & Above FL100 …5/CLB
• FLAPS (if CONF 0,1,2,3) ………MAINTAIN CURRENT CONF
• FLAPS (if CONF FULL) ……..SELECT CONF 3 & MAINTAIN
• SPEEDBRAKES …………………CHECK RETRACTED
• LG…………………….UP
*When at or above MSA or circuit altitude, level off for troubleshooting

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

CEO starter limitation

A

Starter N502-N698 (CEO)
• A standard automatic start that includes only one start
attempt is considered one cycle
• For ground starts (automatic or manual), a 15 s pause
is required between successive cycles
• A 30 min cooling period is required, subsequent to
three failed cycles or 5 min of continuous crank
• For manual start, observe two-minute maximum cycle
time
• For crank, observe 5 min maximum cycle time
• The starter must not be run when N2 is above 10%
on-ground and 18% in-flight

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

NEO starter limitation

A

Starter N901-N928 (NEO)
• A standard automatic start that includes up to two
start attempts, is considered one cycle
• For ground starts (automatic or manual), a 35 s pause
is required between successive cycles
• A 15 min cooling period is required, subsequent to
three failed cycles, or 15 min of continuous or
cumulative crank
• The starter must not be run when N2 is above 20%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly