MD500 Flashcards
1
Q
Torque 5 min T/O
A
87.2
2
Q
Torque MCP above 738 TOT
A
74.3
3
Q
Torque MCP Below 738 TOT
A
81.3
4
Q
Torque Transient 15s Limit
A
87.3 to 93 for 15s
5
Q
Torque Transient 3s limit
A
93.1 to 97.6 for 3 s
6
Q
TOT 5 min T/O
A
810
7
Q
TOT Transient
A
810-843 for 6 s
8
Q
TOT Start
A
810 to 927 for 10s
9
Q
TOT MCP above 74.3 Torque
A
738
10
Q
TOT MCP Below 74.3 Torque
A
755
11
Q
NR Power On
A
102-103
12
Q
NR Power Off
A
87-109
13
Q
N1 MCP
A
105%
14
Q
N1 Transient
A
106 for 15s
15
Q
N1 Start below -18
A
12%
16
Q
N1 Start -18 to 7
A
13%
17
Q
N1 Start above 7
A
15
18
Q
Starter Limits
A
1 min on, 1 min off, 1 min on, 23 min off
19
Q
Generator MCP
A
85 amps
20
Q
Generator time 85 to 150 amps
A
10 min
21
Q
Generator time >150 Amps, prior takeoff
A
2 min
22
Q
Oil Pressure <79%N1
A
50 PSI
23
Q
Oil Pressure 79-94% N1
A
90 PSI
24
Q
Oil Pressure above 94% N1
A
115
25
Max oil Temp
107
26
VNE
156
27
VNE Auto
131
28
VNE less than 35lbs fuel
130
29
VNE Doors off 2501lbs +
130
30
VNE doors off less than 2500lbs
120
31
VNE Bubble window
87
32
Max DA
16000
33
Max Altitude Warmer than 5C on ground
14000
34
Max altitude less than 5C on ground
12000
35
Inlet Temp Limit less than 6k Ft
54C
36
Inlet temp limit 6k to 20k ft
54 to 27 linearly
37
MGW
3000
38
MGW External
3550
39
Min GW
1538
40
Weight Limit Rear Floor
1300lbs 115/ft2
41
Anti Ice Required
5C and vis Moisture
42
Max temp Snow Deflectors
28 minus 2 for every 1000’
43
Fuel Low Light
35lbs
44
Min Desc Auto A/S
60
45
Max Glide Auto A/S
80
46
One Way lock Speed
100
47
TR Failure Speed
50-60
48
Fuel Capacity
421.9
49
Required Equipment
ELFO
Engine Failure Warning System, Low Rotor Warning System, Fuel Low Caution Light, OAT
50
Full Forward Cyclic Trim Failure Wind
15kts downwind prohibited
51
Doors Off Configs
Any One Door
All Doors Off
Both Rear Doors
Loose items secured or stowed
52
Reignition System
55% N1, 98% NR, NR or N1 tach failure will turn on system until shutdown or disarm, failure of eng out /low rotor makes it inop
53
MR Diameter
26.41’
54
Falling or Blowing Snow
Reignition Kit, Eng Failure warning system, Inlet Diverter
55
Unusable Fuel
1.9 Gal, 13.1lbs check
56
Fuel System Purging Req’d x 4
Engine flameout Fuel Exhaustion
Draining from engine compartment drains w/o start pump
Use of emerg shutoff valve for engine shutdown
Motoring engine w/o fuel in tank
57
Viking Pod VNE Descent
90kts
58
Viking Pod MGW
500lbs
59
Fargo Tank
21 USG
Push Plunger at 200lbs
Transfer in 25 minutes
Pull plunger before refueling
60
Cargo Hook VNE
80
61
Cargo Hook Altitude
14000 DA
62
CG Limits
99 fwd, varies based on weight backwards, 3 sideways