Manual Trips Flashcards

1
Q

List Manual Turbine Trip Criteria.

A
  • Bearing 1 - 6 metal > 250°F
  • Bearing 7 - 8 or Thrust Bearing metal > 225°F
  • Any bearing oil drain > 180°F
  • Emergency Oil Trip Press < 1000 psig
  • Unbalanced Phase Current, AM-880 >20% (pegged high), generator damage after 20 sec
  • SG Level > 80 [75] % NR
  • Turbine Vibration > 14 mils
  • Turbine AVG Hot Gas Temp > 113°C
  • Condenser Back Pressure
  • > 8.5 inHgA
  • Δ > 2.5 inHgA
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

List Turbine Auto Trips.

A
  • Overspeed > 1998 rpm
  • Bearing Oil Press < 6.0 psig
  • Thrust Bearing Position > 40 mils
  • Exhaust Hood Spray > 250°F
  • Condenser Vac: 8.859 inHgA
  • Thrust Bearing Position: +40 mils
  • ET Trip Header Press: 1000 psig
  • SG Level > 90 [81]% NR
  • Rx Trip Switchgear Undervoltage
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

List Manual Reactor Trip Criteria.

A

RCS Leak > available charging pump capacity
SG Level < 40% NR due to:
* Loss of Main Feed Pump
* Loss of Cond Pump
* MFP Recirc failing open
* Feed Reg Valve problems
Main Steam Leak, 2 of 4 Rx Pretrips:
* Power High
* Cont Press >2.5 psid
CEAs:
* Motion with Rod Control in Off
* >1 CEA: misaligned >15” or dropped
Instrument Air Press < 60 psig
Traveling Screen 40” Δ & CW Pump Throttled

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

List RCP Manual Trip Criteria (AFTER Tripping Rx)

A

Motor Stator > 311°F
Motor Amperes > 600 amps
[Motor Vibration > 14 mils]
Pump Vibration > 25 mils
CBO Flow is 0 gpm for > 30 minutes
CBO or Lower Seal Cavity Temp:
* 300°F
* 250°F for > 10 minutes
CCW Flow is LOST for > 10 minutes
Seals: 3 Failed
Guide Bearings > 185°F
Thrust Bearings > 200°F
Valid Oil Reservoir Level Off Scale (+ 5”)
Main Spray Valves, PCV-1100E or F stuck open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

List Rapid Downpower Criteria.

A

RCS Leak: If requires T.S. shutdown
SGTL > 100 gpd (<50% in 1 hr, M3 next 2 hrs)
SG Lowering Levels:
* Loss Heater Drain Pump (~90%)
* Heater Tube Rupture (~90%)
Main Steam Leak in Cont Press >1 psig/hr
Instrument Air Press < 75 psig
RCP due to:
* Oil Reservoir Leak > 0.5”/hour
* Seals: 2 Failed
* CBO Flow > 3 gpm
Turbine due to:
* Loss of both Isophase fans (<15.99 KAmps)
Cold Gas maintain > 50.7°C due to:
* TCW problems
* ICW problems
TCW leak into H2 Cooler (<80%)
* Stator Temp (<80%)
* MAX HOT GAS DELTA REDUCE VALUE
* MAX HOT GAS DELTA TRIP VALUE
Loss of RCB Cooling Fans:
* HVE-21A & B, CEDM
* HVS-2A & B, Rx Cavity
* HVE-3A & B, Rx Support
* HVS-1A > D & Cont Temp > 120°F
Traveling Screen 20” Δ

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6