Lecture 13 - Overdenture Flashcards
Minimum height for locator attachment
10.35 (or 12 mm)
Tissue height (3 mm) + supra-gingival abutment and housing height (2.35) + acrylic (2 mm)+ tooth stock (3 mm)
What abutment system for divergent implants? (Angulation?)
ERA attachment
- 0, 5, 11, 17
- Height for ball attachment
2. Angulation?
- 10 to 12 mm
2. 10-30 degrees
What kind of retention bar in splinted implants w/ bar?
- How much width needed?
Hader bar (requires 13 mm)
When should you consider bar for over denture attachment?
- Anatomic structures need protection and retrievability for oral hygiene needs to be maintained
- Implants >30 degree divergence
Difference between attachment systems and patient satisfaction?
No significant difference
How does off parallel implant placement affect longevity of retention systems?
Increases wear rates and decreases retention
What are the four advantages to digital dentures?
- Time
- Pre-cured resin
- Portability
- Permanent digital record
What are the five disadvantages to digital dentures?
- Cost
- Cases with limited restorative space
- Static occlusal record (no excursive movements)
- Not entirely digital
- Many steps condensed into first visit