Clearance for water closet lavatories and bidets
15 in minimum center to sidewall partition or vanity
Clearance between adjacent
30 in minimum center to center
Clarence in front of water closet
21 inches minimum
Clearance in front of lavatory or bidet
21-in minimum the location of piping fixtures and equipment must not interfere with the operation of Windows and doors
Max flow rates and consumption for plumbing fixtures and fixture fittings
Lavatory faucet 2.2 at 60 PSI
Shower head 2.5 at 80 psi
Sink faucet 2.2 at 60 PSI
Water closet 1.6 gallons per flushing cycle
Hey handheld shower spray is considered to be a shower head
Floor outlet or floor mounted fixtures
Must be secured to the drainage connection into the floor by screws bolts washers nuts and similar fasteners of copper copper alloy or other corrosion resistant material
Well hung fixtures
Must be originally supported so that the strain is not transmitted to the plumbing system
Watertight contact area
Where fixtures come in contact with the walls and floors to contact area must be watertight
Functionality
Fleming’s fixtures must be usable
The location of piping pictures or equipment must not interfere with the operation of Windows or doors
Flood hazard
And what has your areas and established by table r30 1.2 plumbing fixtures shall be located or installed in accordance with section or 322.1.6
Fixed your supply outlet serving bathtub
Flow rate 4 gallons a minute flow pressure 20 psi
Picture supply outlet serving bidet thermostatic mixing valve
Flow rate 2 gallons per minute flow pressure 20 psi
Fixture supply outlet serving dishwasher
Flow rate 2.75 low pressure 8 PSI
Fix your supply outlet serving laundry tray
Flow rate 4 gallons per minute low pressure 8 PSI