Jeopardy Deck Flashcards

1
Q

You must do this in order for the microinverters to communicate with the envoy

A

Provision microinverters

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

An Envoy R uses these two forms of communication to connect to the Enlighten portal

A

Wifi and Ethernet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

These two devices are used to help reduce noise interference on Enphase systems

A

Ferrite rings and In-line Filters

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Navigate to this in the Enphase portal to see how far along a data upload has caught up to

A

Admin view of the envoy

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

This microinverter sku is the compatible replacement for a M215

A

A M215-IQ7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When swapping an A series to an H series a technician requires this duration

A

3 Hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

You use this function in SolarEdge portal to update the inverter after it has been replaced

A

Logical Layout - Replace function

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The 3x6E Error in SolarEdge indicates this

A

3x6E Meter Communication

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

SolarEdge inverters requires this number of panels to be paired to it in order for it to be able to have enough voltage to ‘wake up’

A

8 Panels

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

When the middle LED light on the inverter is flashing green, it indicates this

A

AC is connected but the system is not producing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

These two things must be listed in Salesforce assets as meters for Enphase systems in order for the system to report to NOC/Spotlight

A

The Enlighten site ID and the Envoy serial number

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

SolarEdge and Delta inverters are listed in Salesforce assets as this

A

A meter

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

This is needed in ALL assets in order to report to NOC/Spotlight

A

In service dates

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

When entering a CAT M1 serial number into Salesforce assets you add in what portion of the serial number

A

The numeric portion only

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

This is used as the meter asset for Vivint migrated Fronius systems

A

The Fronius portal site ID

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

We must be able to see the gateway in this in order to see production data in NOC/Spotlight from Tesla

A

Powerhub

17
Q

Most systems is Califorina use this type of battery profile

A

Time of Use (TOU)

18
Q

The 3x6B Error in SolarEdge indicates this

A

A battery communication error

19
Q

These are the 5 manufacturers of batteries that Vivint/Sunrun has installed

A

LG, Tesla, Sonnen, SolarEdge and Enphase

20
Q

Due to NEM 3.0 in California, this setup will be used for new battery installs

A

SHIFT

21
Q

All systems must have this in order to be serviced

A

Permission to Operate(PTO)

22
Q

For deactivation cases once you have disabled power production OR set the inverter to standby you should ALWAYS do this

A

Set the account status to ‘Deactivated’ On the Service Contract page

23
Q

Systems in these three states are required to report through RGM for SREC purposes

A

New Jersey, Massachusetts & Illinois

24
Q

In these three utility service areas that are part of NEM 3.0 we have to submit DSR for inverter replacement that would require upsizing

A

PG&E, SDG&E and SCE

25
Q

This is required in order for the customer to be reimbursed for conduit painting

A

The HOA requirement letter