ISO 11338 - PAHs Flashcards
What does the term PAHs stand for?
ISO 11338 - PAHs
Polycyclic Aromatic Hydrocarbons
ISO 11338 - PAHs
What defines a PAH?
ISO 11338 - PAHs
Contain 2 or more fused aromatic rings of just carbon and hydrogen
ISO 11338 - PAHs
What are the major sources of PAHs?
ISO 11338 - PAHs
Aluminium smelters, coal works, waste incinerators and power stations
ISO 11338 - PAHs
What are the 3 different equipment configurations for sampling PAHs?
ISO 11338 - PAHs
- Filter / condenser method
- Dilution method
- Cooled probe method
ISO 11338 - PAHs
Name the 3 normative references in ISO 11338
ISO 11338 - PAHs
ISO 4225 - air quality general aspects
ISO 9096 - determination of dust
ISO 12141 - determination of dust
ISO 11338 - PAHs
Name the 6 analysis techniques for quantifying PAHs
ISO 11338 - PAHs
- HPLC
- Fluorescence detector
- Diode array
- GC-FID/MS
- HR GC-MS
- GC-QqQ
ISO 11338 - PAHs
When is a leak check required?
ISO 11338 - PAHs
Before and after the sampling run
ISO 11338 - PAHs
What should the samples be protected from both during and after sampling?
ISO 11338 - PAHs
Light
ISO 11338 - PAHs
How many days following sampling should the samples be extracted?
ISO 11338 - PAHs
7 days (ideally 24 hours)
ISO 11338 - PAHs
At what temperature does the standard require samples post-sampling to be stored at?
ISO 11338 - PAHs
-7°C (EA allow transportation at < 25°C)
ISO 11338 - PAHs
What is the allowable leak?
ISO 11338 - PAHs
< 5% of expected sample flow
ISO 11338 - PAHs
List the 4 permissible sampling train materials?
ISO 11338 - PAHs
Glass | Quartz | Titanium | PTFE
ISO 11338 - PAHs
Filter / Condenser / Absorber Method
What are the sample flowrate and exit temperature requirements?
ISO 11338 - PAHs
Sample gas flowrate between 1 and 6 m³/hr (16 to 100 l/min)
Temperature after the condenser should be < 20°C
ISO 11338 - PAHs
What temperature should the filter be heated to?
ISO 11338 - PAHs
Above the stack gas dewpoint, nominally 120°C
ISO 11338 - PAHs
What shall the measurement uncertainty value at the daily ELV not exceed
ISO 11338 - PAHs
± 25% on a dry gas basis before correction to oxygen
ISO 11338 - PAHs